HP 83205A-001

CDMA Cellular Adapter HP 83205A Product Details

The Agilent Technologies 83205A CDMA/CDPD Cellular Adapter adds optional CDMA and/or CDPD measurement capability to the Agilent Technologies 8921A for IS-95A/97 CDMA base station testing and/or CDPD Mobile Data Base Station (MDBS) testing. The 8921A retains its full capability for testing the analog performance of dual-mode CDMA base stations.

Features:

  • Adds the following CDMA measurements to the Agilent Technologies 8921A

  • Code domain power, timing, and phase analysis

  • Waveform quality (rho), frequency error, and pilot time offset

  • True-average power and CDMA channel power measurements

  • Built-in Added White Gaussian Noise (AWGN) source for calibrated Eb/No settings

  • Optional CDPD Mobile Data Base Station (MDBS) test capability

Specifications:

CDMA Signal Generator

Frequency Range: 824 to 894 MHz (usable from 800 MHz to 1000 MHz and from 4 MHz to 200 MHz with degraded rho and carrier feedthrough performance) Output Level Range: RF In/Out: -19 to -137 dBm Duplex Out: +4 to -127 dBm Output Level Accuracy: RF In/Out: +/-2.0 dB Typically +/-1.0 dB Duplex Out: +/-1.7 dB typically +/-1.0 dB Residual rho: better than 0.96, typically > 0.98 Reverse Link Source Modulation: OQSPK per TIA IS-95 Reverse Link Source Modulation Data: internal data buffer, Idle (all zeroes) PN Offset: Adjustable from 0 to 511 units (1 unit = 64 chips) Data Buffer: Size/length: 5400 frames Modes: Single, Continuous Looping, and Idle Input Data Rate: 9600 bps; 14,400 bps

CDMA Analyzer
Waveform Quality Measurement(rho) IS-95 forward or reverse link formats (QPSK or OQPSK) Input Frequency Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Rho Measurement Range: 0.5 to 1.00 Rho Measurement Accuracy: < +/-0.005 Frequency Error Measurement Accuracy: +/-30 Hz using a measurement interval >/= 0.5 ms Average Power Measurement Input Frequency Range: 30 MHz to 1000 MHz Measurement Range: 1 mW to 60 W (0 to +48 dBm) Measurement Accuracy: +/-5% +/-1 uW, at 25 degrees C +/-10 degrees C +/-10% +/-1 uW, from 0 degrees to 55 degrees C Channel Power Measurement Input Frequency Range: 4 MHz to 1000 MHz Mesurement Range: -10 dBm to +48 dBm Measurement Accuracy: +/- 1 dB over a range of +/- 5 degrees C from the temperature of last calibration

Code Domain Analyzer
Code Domain Power Mesurement Input Frequency Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Dynamic Range: 40 dB Measurement Accuracy: +/- 0.5 dB using a measurement interval >/= 0.5 ms Carrier Frequency Offset Accuracy: +/- 30 Hz using a measurement interval >/= 0.5 ms Pilot Time Offset Accuracy: typically <500 nsec from even second signal to start of PN sequence Code Domain Timing Measurement (Pilot to Code Channel Phase Tolerance) Input Level Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Accuracy: +/- 10 ns using a measurement interval of 1.25msand >/= 10 averages Code Domain Phase Measurement (Pilot to Code Channel Phase Tolerance) Input Frequency Range: 1 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Accuracy: +/- 20 mrad using a measurement interval of 1.25 ms and >/= averages

CDMA Reference
Input Frequencies: 19.6608 MHz, 15 MHz, 10 MHz, 9.8304 MHz, 5 MHz, 4.9152 MHz, 2.4576 MHz, 1.2288 MHz, and 1 MHz Even Second Sync Input: (BNC) accepts a rising edge to reset the internal short sequences and CDMA clocks. Periodic inputs should have a period of 2 seconds and a minimum pulse width of > 50 ns

CDPD Specifications
The following CDPD specifications apply when the 83205A option 002 or 003 is operating with the 8921A:

CDPD Signal Generator (at HP8921A DuplexOut)
Output: Level Range and Level Accuracy: Same as Agilent Technologies 8921A Reverse Power: Same as Agilent Technologies 8921A Frequency Range: Same as Agilent Technologies 8921A Frequency Accuracy: ±500Hz, typically ±50Hz Spectral Purity: Spurious Signals, Adjacent Channels: <-26 dBc Spurious Signals, First Alternate Channel: <-45 dBc Spurious Signals, Second Alternate Channel: < 60 dBc Switching Speed: Typically <150 msec to be within 1 kHz Transmitter On/Off Level and Timing: >15 dB down in <1msec Modulation Type: GMSK with BT=0.5 Modulation Accuracy: <5% errorin modulation index

CDPD Analyzer
RF Frequency Range: Same as Agilent Technologies 8921A Input Level Range: Same as Agilent Technologies 8921A RF Power Measurement: Accuracy: RF in/out: 5%, ±0.01 mW (at 25°±10°C) for single signal >200 mw, 10% over full temperature range Frequency Error Accuracy: Time base accuracy ±1 Hz Modulation Index Accuracy: <0.1% error in modulation index Adjacent Channel Power measurement floor: Typically -45 dBc Alternate Channel Power measurement noise floor: Typically -55 dBc for input levels > -34 dBm

 

 



 
 