Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
Electronic Test Equipment - MetricTest   Advanced
1.800.417.4370
 

HP 16518A

State/Timing Module

Trace more channels with higher accuracy than ever before in a logic analyzer. The 64K deep memory lets you capture data over many clock cycles while retaining the highest multi-channel accuracy ever in a logic analyzer. Solve your toughest problems with the fastest, most flexible state analysis available. This expansion card requires the Agilent 16517A 16-Channel, 4 GHz Logic Analyzer High-Speed State and Timing Module.

Features:

  • Find the Cause of Elusive Problems
    Verify the timing of critical edges with 250 ps resolution across up to 40 channels, or 500 ps resolution across up to 80 channels. Use the 1 GSa/s synchronous state analysis to view high-speed data streams across up to 80 channels.

  • The Ultimate in Timing Resolution and Accuracy
    The 250 ps resolution of this analyzer is only part of the story. An innovative approach, using phase-locked loops, keeps the skew between channels to +/- 250 ps.

  • Precisely Characterize Setup or Hold Times
    The 250 ps precision (channel-to-channel skew) allows this logic analyzer to be used in place of an oscilloscope for characterization. The high channel count of a logic analyzer makes this a much more efficient process.

  • Modularity
    Agilent Technologies modular 16500C family lets you configure your mainframe with the modules you need today, while providing you the flexibility to grow with your evolving digital design needs.

 

Specifications:

Timing Analysis
Max. Sample Speed: 2 GSa/s full channel; 4 GSa/s, half channel Channels/Card: 16, full channel, 8, half channel Max. Channels (5 cards): 80, full channel; 40, half channel Memory Depth: 64 K, full channel; 128 K, half channel Sample Period Accuracy: 0.005% of sample period Channel-to-Channel Skew: 250ps, typical Time Interval Accuracy: +/-(sample period + channel-to-channel skew + 0.01% of time interval reading

Synchronous State Analysis
Max. Sample Speed: 1 GSa/s, 2 GSa/s Channels/Card: 16 Max. Channels (5 cards): 80 Memory Depth: 64 K Setup/Hold Time: 350/350 ps (with deskew) adjustable with sample placement Sample Placement with Respect to External Clock Edge: +/-5 ns in 200ps increments (course adjustment) +/-250 ps in 50 ps increments (fine adjustment) Number of Samples/External Clock: Adjustable in increments of 1,2,4,8,16,32 Max. Sample Rate, with Oversampling: 2GSa/s Triggering
Sequencer Speed: 500 MHz, maximum State/Timing Sequence Levels: 4 Pattern Recognizers: 4 Max. Channel Width for Patterns: 16-one card 32-two cards 48-three cards 64-four cards 80-five cards Edge Recognizers(Timing only): 2 Max. Channel Width for Edges: 16-one card 32-two cards 48-three cards 64-four cards 80-five cards Max. Number of Recognizers at One Time: 4 Timers/Counters: 1 per sequence level
Probes
Input dc Resistance: 100 kOhms, +/-2% Input Impedance: 500 Ohm typical, at 100 MHz through 1 GHz Input Capacitance: 0.2 pF and then, through 500 Ohm 3pF Min. Voltage Swing: 500 mV peak-to-peak Threshold Range: +/-5.0 V, adjustable in 10 mV increments

Ordering Information:

Agilent HP 16518A 16-Channel, 4 GHz High-Speed State and Timing Module

Agilent 16518A 16-Channel, 4 GHz High-Speed State and Timing Module Expansion Card
      Opt 110 1M/2.5M to 4M CPU upgrade
      Opt 0B0 Delete Operating, Programming, and Service Manuals
      Opt AV8 Extra Operating and Programming Manuals
Agilent 16518A Calibration / Standards Compliant Calibration Options


 
 
  Company    |   Contact Us   |   Site Map 1.800.417.4370
 
 
 
 
Copyright©2008 MetricTest. All rights reserved. Privacy & Security