HP 5361B
Pulse/CW Frequency Counter, 20GHz
The Agilent Technologies 5361B offers both high-precision pulse and CW
performance up to 40 GHz. With built-in frequency modulation profiling,
the 5361B characterizes radar, EW, and communications systems or components.
The counter makes complex measurements for the carrier frequency of agile
signals, staggered PRIs, or the frequency transients in a pulsed or CW
signal. It can be used to characterize radar pulses or test a Stable Local
Oscillator (STALO). Functions for measuring step response, post-tuning
drift, and settling time facilitate accurate and easy testing of VCOs
and DTOs.
The 5361B helps lower your equipment costs by eliminating the need for
a separate CW counter, pulse generator and computer, and is a cost-effective
choice for manufacturing and R&D. High-speed throughput saves operator
time, and periodic maintenance is limited to time base calibration.
Features:
- Precise pulse measurements to 20, 26.5, or 40 GHz.
- PROFILE function characterizes frequency transients, modulation (such
as chirp), and linearity.
- Simple-to-use automatic functions include calibration, pulse averaging,
and measurement display.
- Scope-View provides confidence and easy setup for externally gated
measurements.
- Fast track measures a signal sweeping up to 800 MHz per second.
- Low FM rate allows measurement of signals that vary slowly in frequency.
Specifications:
Frequency range
500 MHz to 20, 10 Hz to 10 MHz to
26.5, 40 GHz 80 MHz 525 MHz
Sensitivity 25 mV rms 25 mV rms
0.5 to 12.4 GHz -28 dBm
12.4 to 20 GHz -23 dBm
0.5 to 26.5 GHz -20 dBm
(Opt 026, 040)
26.5 to 40 GHz 0.37 x f (in GHz)
(Opt 040) -29.8 dBm
Frequency (Input 1)
Automatic and Manual Acquisition: 500 MHz to 20 GHz; 500 MHz to
26.5 GHz (Option 026); 500 MHz to 40 GHz (Option 040)
Least Significant Digit: 1 MHz to 1 Hz for frequency, 0.001 Hz for PRF
Pulse Frequency Measurements
Pulse width (minimum): manual mode, 60 ns; auto mode, 100 ns
Pulse rep freq: minimum 1 Hz; maximum 2 MHz
Measurement time, resolution, accuracy: See datasheet
CW Frequency Measurements
FM tolerance: 55 MHz peak-to-peak
Tracking speed (fast acquisition): 800 MHz/s
Acquisition time: Manual mode, <40 ms; automatic mode, fast
acq., <100 ms
Gate times (1 Hz resolution): 200 to 1000 ms
Measurement time:
8.5 ms (in Dump Mode)
Accuracy: See datasheet
Pulse Parameters (Input 1)
Pulse Width PRI Offtime PRF
Min./Max. 60 ns/10 ms 500 ns/1 s 400 ns/1s 1Hz/2 MHz to 0.001 Hz
LSD (PW <1 ms) 1 ns;(PW ) 100 nx
Accuracy: ±(20 nx + timebase uncertainty x ± (20 nx) x (PRF) 2
(100 ave.) measurement ±LSD ±LSD ±timebase uncertainty
Pulse Parameters (Input 1)
| |
Pulse width |
PRI |
Offtime |
PRF |
| |
| Min/Max: |
60 ns/10 ms |
500 ns/1 s |
400 ns/1 s |
1 Hz/2 MHz
|
| LSD: |
(PW <1 ms) 1 ns; (PW >= 1 ms) 100 ns
|
to 0.001 Hz |
Accuracy:
(100 avg.) |
±(20 ns + timebase uncertainty x
measurement ±LSD |
|
±(20 ns) x (PRF)2
±LSD ±timebase
uncertainty
|
Profile (Input 1)
Frequency Range (min/max for Y axis): 500 MHz/40 GHz
FM Chirp Tolerance (max span for Y axis): 50 MHz peak-to-peak
Time Range (min/max span for X axis): 100 ns/10 ms; 1 ns resolution
Internal Gate Width: Minimum 11 ns to 23 ns; typical minimum: 14 ns
External Gate Width: Minimum: Manual acquisition 20 ns;auto
acquisition 60 ns
Number of Data Points: Up to 100
Profile Frequency Measurements
Printers supported: HP 2225A, HP 227B, HP 3630A Opt 002
Profile phase measurements: See Application Note 377-4 for
details. Computer required.
Frequency (Input 2)
Range: 10 Hz to 525 MHz
Accuracy: 0.001 Hz to 1 Hz
Resolution/LSD: 0.001 to 1 Hz
|