Hp 8510c

Features:

  • 45 MHz to 110 GHz frequency
  • The fastest sweep mode available for any network analyzer
  • Thru-Reflect-Line precision two-port calibration for coaxial measurements
  • Line-Reflect-Match calibration for on-wafer and in-fixture applications
  • Internal "adapter removal" feature for measuring noninsertable devices with exceptional accuracy
  • Four S-parameter color display
  • Data storage on an internal 3.5 disk drive or data output to an HP-IB or serial (RS-232) plotter or printer

Specifications:

Since HP 8510 systems are modular, specifications will vary depending upon customer application requirements. These performance specifications compare two of the most popular systems featuring the HP 8510C Vector Network Analyzer: the HP 8510E and the HP 8510SX.

Dynamic Range (for transmission measurements) Frequency Range (GHz) 0.045-2 2-8 8-20 20-26.5 ----------------------------------------------------------------------------- Maximum power measured at port 2 HP 8510E Opt 005 +20 dBm +11 dBm +10 dBm HP 8510SX +2 dBm +3 dBm +3 dBm -1 dBm Reference power (dBm) at port 1 (nominal) HP 8510E Opt 005 +2 dBm -2 dBm -6 dBm HP 8510SX -5 dBm -9 dBm -14 dBm -25 dBm Minimum power (dBm) measured at port 2 HP 8510E Opt 005 -66 dBm -95 dBm -95 dBm HP 8510SX -101 dBm -102 dBm -101 dBm -99 dBm Receiver dynamic range (dB) HP 8510E Opt 005 +86 dBm +106 dBm +105 dBm HP 8510SX +103 dBm +105 dBm +104 dBm +100 dBm System dynamic range (dB) HP 8510E Opt 005 +68 dBm +93 dBm +89 dBm HP 8510SX +93 dBm +90 dBm +85 dBm +74 dBm Measurement Port Characteristics Frequency Range (GHz) Residual 0.045-2 2-8 8-20 20-56.5 ------------------------------------------------------------------------------ Directivity HP 8510E Opt 005 48 dB 44 dB 44 dB HP 8510SX 48 dB 50 dB 50 dB 50 dB Source Match HP 8510E Opt 005 40 dB 33 dB 31 dB HP 8510SX 40 dB 50 dB 50 dB 50 dB Load Match HP 8510E Opt 005 48 dB 44 dB 44 dB HP 8510SX 48 dB 50 dB 50 dB 50 dB Reflection Tracking HP 8510E Opt 005 ±0.003 dB ±0.003 dB ±0.006 dB HP 8510SX ±0.003 dB ±0 dB ±0 dB ±0 dB Transmission Tracking HP 8510E Opt 005 ±0.017 dB ±0.044 dB ±0.084 dB HP 8510SX ±0.009 dB ±0.004 dB ±0.009 dB ±0.01 dB Crosstalk HP 8510E Opt 005 89 dB 115 dB 110 dB HP 8510SX 117 dB 114 dB 108 dB 95 dB Frequency Range (GHz) Raw (typical) 0.045-2 2-8 8-20 20-26.5 ----------------------------------------------------------------------------- Directivity HP 8510E Opt 005 23 dB 23 dB 14 dB HP 8510SX 24 dB 24 dB 28 dB 27 dB Source Match HP 8510E Opt 005 17 dB 15 dB 11 dB HP 8510SX 23 dB 23 dB 16 dB 14 dB Load Match HP 8510E Opt 005 17 dB 15 dB 11 dB HP 8510SX 23 dB 23 dB 16 dB 14 dB Measurement Throughput Summary The following table shows typical measurement times for an HP 8510C system with full two-port error correction. Number of Points 51 101 201 401 801 -------------------------------------------------------------------- Measurement1 Ramp Sweep2 270 ms 340 ms 470 ms 740 ms 1.3 s Stepped Sweep Avg. Factor = 1 1.25 s 2.5 s 5 s 10 s 20 s Avg. Factor = 128 6.25 s 12.8 s 24 s 49 s 106 s -------------------------------------------------------------------- Time Domain conversion3 50 ms 100 ms 200 ms 400 ms 800 ms -------------------------------------------------------------------- HP-IB Data Transfer to Computer4 Internal Format 20 ms 30 ms 50 ms 100 ms 200 ms ASCII Format 240 ms 460 ms 900 ms 1.8 ms 3.6 ms IEEE 754 Floating Point Format 32 bit 40 ms 40 ms 80 ms 160 ms 320 ms 64 bit 40 ms 80 ms 150 ms 300 ms 590 ms 1. Includes system retrace time, but does not include source bandwidth times (typically 50 msec each). Time domain gating is assumed off. 2. If averaging is used, multiply the above ramp sweep measurement times by the averaging factor to get the total time. 3. Option 010 only, gating off. 4. Measured with an HP 9000 Series 300 computer. Single point data transfers can be accomplished in approximately 1 msec per point using fast CW mode. General Specifications Rear Panel Connectors Sweep In: Input for 0 to 10 V sweep voltage from compatible sweep oscillator Stop Sweep: Input and output for stop sweep signal from compatible sweep oscillator 10 MHz In: Input for external 10 MHz reference Input Level: -10 dBm to +20 dBm, typical Input Frequency Accuracy:±0.005% (50 ppm) 20 MHz Out: Output of internal 20 MHz reference oscillator Frequency Accuracy: ±0.01%, typical Analog ±10 V: Settable output voltage used for auxilliary voltage domain measurements, or analog output for analog recorders Range: -9.995 to +10.000 volts Linearity: ±0.1%, typical Resolution: 4.88 mV, nominal Output Impedance: 1 kohms External Trigger: TTL input to trigger acquisition of single data point. Delay is included to equalize the single path delay from the test port. Data is taken on negative-going TTL pulse. Pulse Repetition Period: 1 msec minimum with no averaging. If averaging, add (200 µs x averaging factor). Pulse Width: 1 µs minimum Environmental Temperature Operating Conditions: 5° to 40°C Non-Operating Conditions: -40° to 75°C Power 47.5 to 66 Hz: 100, 120, 200, 240 Vac, ±10% HP 8510C: 370 VA, maximum Test Sets: 95 VA, maximum Weight Net: 42 kg (92 lb) Shipping: 52 kg (114 lb) Ordering Information:

HP 8510C Vector Network Analyzer

For flexibility in specifying a solution that meets your exact needs, a system can be ordered as separate line items. A complete system includes the HP 8510C network analyzer, a test set, compatible source and measurement accessories.

Analyzer

HP 8510C Vector Network Analyzer, MHz to 110 GHz

Opt 008 Pulsed-RF Measurement Capability Requires HP 85110A S-parameter test set Also, see HP 85108A or 85108L Pulsed-RF Network Analyzer System

Opt 010 Add Time Domain Capability

Opt 908 Add Rack Flange Kit

Opt 913 Add Rack Flange and Handles Kit

Test Sets (Choose One)

HP 8514B S-Parameter Test Set (45 MHz to 20 GHz)
HP 8515A S-Parameter Test Set (45 MHz to 26.5 GHz)
HP 8517B S-Parameter Test Set (45 MHz to 50 GHz)
HP 85110A Pulsed-RF S-Parameter Test Set (2 GHz to 20 GHz)
HP 85110L Pulsed-RF S-Parameter Test Set (45 MHz to 2 GHz)
HP 8511A Frequency Converter (45 MHz to 36.5 GHz)
HP 8511B Frequency Converter (45 MHz to 50 GHz)

Must also order two test set modules for complete waveguide S-parameter test set operation for each waveguide band:

HP Q85104A Test Set Module (33 GHz to 50 GHz)
HP U85104A Test Set Module (40 GHz to 60 GHz)
HP V85104A Test Set Module (50 GHz to 75 GHz)
HP W85104A Test Set Module (75 GHz to 110 GHz)

Single-Connection Single-Sweep Millimeter-Wave Subsystem (Components of HP 8510XF)

HP E7342A Millimeter Subsystem 2 to 85 GHz Consists of two 85 GHz test heads and millimeter test set controller.

Opt 005 Add 45 MHz to 2 GHz low frequency extension

Opt 006 Add RF pass thru Provides coupled output of 50 GHz source for additional test set(s). Additional test set(s) must have Option 001 installed.

HP E7342A Millimeter Subsystem 2 to 85 GHz Consists of two 85 GHz test heads and millimeter test set controller.

Opt 005 Add 45 MHz to 2 GHz low frequency extension

Opt 006 Add RF pass thru Provides coupled output of 50 GHz source for additional test set(s). Additional test set(s) must have Option 001 installed.

Sources (Choose an HP 8360 Series Synthesized Sweeper)

HP 83651B Synthesized Sweeper (45 MHz to 50 GHz)
HP 83631B Synthesized Sweeper (45 MHz to 26.5 GHz)
HP 83621B Synthesized Sweeper (45 MHz to 20 GHz)
HP 83620B-H80 Synthesized Sweeper (45 MHz to 2 GHz) for HP 85110L only
HP 83622B Synthesized Sweeper (20 GHz to 20 GHz) for HP 85110A
HP 83623L Synthesized Sweeper (45 MHz to 20 GHz) for HP 85110A

Electronic Calibration

HP 85060C Electronic Calibration Control Unit
HP 85060A Calibration Kit, 1 to 18 GHz, 7 mm
HP 85062A Calibration Kit, 1 to 26.5 GHz, 3.5 mm
HP 85064A Calibration Kit, 1 to 18 GHz, Type-N

Mechanical Calibration Kits

Standard HP 85050B Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052B Calibration Kit, 0.045 to 26.5 GHz, 3.5 mm
HP 85054B Calibration Kit, 0.045 to 18 GHz, Type-N
HP 85056A Calibration Kit, 0.045 to 50 GHz, 2.4 mm

Precision

HP 85050C Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052C Calibration Kit, 0.045 to 26.5 GHz, 3.5 mm
HP 85059A Calibration Kit, 0.045 to 110 GHz, 1.0 mm
HP X11644A Calibration Kit, 8.2 to 12.4 GHz, WR-90
HP P11644A Calibration Kit, 12.4 to 18 GHz, WR-62
HP K11644A Calibration Kit, 18 to 26.5 GHz, WR-42
HP R11644A Calibration Kit, 26.5 to 40 GHz, WR-28
HP Q11644A Calibration Kit, 33 to 50 GHz, WR-22
HP U11644A Calibration Kit, 40 to 60 GHz, WR-19
HP V11644A Calibration Kit, 50 to 75 GHz, WR-15
HP W11644A Calibration Kit, 75 to 110 GHz, WR-10

Economy

HP 85050D Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052D Calibration Kit, 0.045 to 26.5 GHz, 3.5 mm
HP 85054D Calibration Kit, 0.045 to 18 GHz, Type-N
HP 85056D Calibration Kit, 0.045 to 50 GHz, 2.4 mm
HP 85058D Calibration Kit, 0.045 to 65 GHz, 1.85 mm

Open and Short Circuits, Fixed Terminations and In-Series Adapters HP 85056K

Verification Kits

HP 85051B Verification Kit, 0.045 to 18 GHz, 7 mm
HP 85053B Verification Kit, 0.045 to 26.5 GHz, 3.5 mm
HP 85055A Verification Kit, 0.045 to 18 GHz, Type-N
HP 85057B Verification Kit, 0.045 to 50 GHz, 2.4 mm
HP R11645A Verification Kit, 26.5 to 40 GHz, WR-28
HP Q11645A Verification Kit, 33 to 50 GHz, WR-22
HP U11645A Verification Kit, 40 to 60 GHz, WR-19
HP V11645A Verification Kit, 50 to 75 GHz, WR-15
HP W11645A Verification Kit, 75 to 110 GHz, WR-10

Test Port Return Cables Use these cables for applications where the device under test is connected directly to the test set port.

Single Cables for HP 8514B, 8515A, 85110A and 85110L Test Sets (3.5 mm rugged test port connector)
HP 85131C Semi-Rigid Cable, 3.5 mm (f)
HP 85131E Flexible Cable, 3.5 mm (f)
HP 85132C Semi-Rigid Cable, 7 mm
HP 85132E Flexible Cable, 7 mm

Single Cables for HP 8517B Test Set (2.4 mm rugged test port connector) HP 85133C Semi-Rigid Cable, 2.4 mm (f)
HP 85133E Flexible Cable, 2.4 mm (f)
HP 85134C Semi-Rigid Cable, 3.5 mm (f)
HP 85134E Flexible Cable, 3.5 mm (f)
HP 85135C Semi-Rigid Cable, 7 mm
HP 85135E Flexible Cable, 7 mm

Use these cables for applications where the device under test is connected between cable ends. This setup offers more flexibility when connecting to the device under test.

Cable Set for HP 8514B, 8515A, 85110A and 85110L Test Sets (3.5 mm rugged test port connector)
HP 85131D Semi-Rigid Cable Set, 3.5 mm (m and f)
HP 85131F Flexible Cable Set, 3.5 mm (m and f)
HP 85132D Semi-Rigid Cable Set, 7 mm
HP 85132F Flexible Cable Set, 7 mm

Cable Set for HP 8517B Test Set (2.4 mm rugged test port connector)
HP 85133D Semi-Rigid Cable Set, 2.4 mm (m and f)
HP 85133F Flexible Cable Set, 2.4 mm (m and f)
HP 85134D Semi-Rigid Cable Set, 3.5 mm (m and f)
HP 85134F Flexible Cable Set, 3.5 mm (m and f)
HP 85135D Semi-Rigid Cable Set, 7 mm
HP 85135F Flexible Cable Set, 7 mm

HP 11500I Test Port Cable, 1.0 mm (m and f)
HP 11500J Test Port Cable, 1.0 mm (m and f)

Adapters
HP 85130B Adapter Set, 7 mm
HP 85130C Adapter Set, 3.5 mm to Type-N
HP 85130D Adapter Set, 3.5 mm (m and f)
HP 85130E Adapter Set, 7 mm
HP 85130F Adapter Set, 3.5 mm (m and f)
HP 85130G Adapter Set, 2.4 mm (m and f)
HP 11904S Adapter Set, 2.92 mm, 0.045 to 40 GHz
HP V281C Adapter V-Band Waveguide, 1.0 mm (f) to V-Band
HP V281D Adapter V-Band Waveguide, 1.0 mm (m) to V-Band
HP W281C Adapter W-Band Waveguide, 1.0 mm (f) to W-Band
HP W281D Adapter W-Band Waveguide, 1.0 mm



 
 