Hp 8510c
Features:
- 45 MHz to 110 GHz frequency
- The fastest sweep mode available for any network analyzer
- Thru-Reflect-Line precision two-port calibration for coaxial measurements
- Line-Reflect-Match calibration for on-wafer and in-fixture applications
- Internal "adapter removal" feature for measuring noninsertable
devices with exceptional accuracy
- Four S-parameter color display
- Data storage on an internal 3.5 disk drive or data output to an HP-IB
or serial (RS-232) plotter or printer
Specifications:
Since HP 8510 systems are modular, specifications will vary depending
upon customer application requirements. These performance specifications
compare two of the most popular systems featuring the HP 8510C Vector
Network Analyzer: the HP 8510E and the HP 8510SX.
Dynamic Range (for transmission measurements)
Frequency Range (GHz)
0.045-2 2-8 8-20 20-26.5
-----------------------------------------------------------------------------
Maximum power
measured at port 2
HP 8510E Opt 005 +20 dBm +11 dBm +10 dBm
HP 8510SX +2 dBm +3 dBm +3 dBm -1 dBm
Reference power (dBm)
at port 1 (nominal)
HP 8510E Opt 005 +2 dBm -2 dBm -6 dBm
HP 8510SX -5 dBm -9 dBm -14 dBm -25 dBm
Minimum power (dBm)
measured at port 2
HP 8510E Opt 005 -66 dBm -95 dBm -95 dBm
HP 8510SX -101 dBm -102 dBm -101 dBm -99 dBm
Receiver dynamic range (dB)
HP 8510E Opt 005 +86 dBm +106 dBm +105 dBm
HP 8510SX +103 dBm +105 dBm +104 dBm +100 dBm
System dynamic range (dB)
HP 8510E Opt 005 +68 dBm +93 dBm +89 dBm
HP 8510SX +93 dBm +90 dBm +85 dBm +74 dBm
Measurement Port Characteristics
Frequency Range (GHz)
Residual 0.045-2 2-8 8-20 20-56.5
------------------------------------------------------------------------------
Directivity
HP 8510E Opt 005 48 dB 44 dB 44 dB
HP 8510SX 48 dB 50 dB 50 dB 50 dB
Source Match
HP 8510E Opt 005 40 dB 33 dB 31 dB
HP 8510SX 40 dB 50 dB 50 dB 50 dB
Load Match
HP 8510E Opt 005 48 dB 44 dB 44 dB
HP 8510SX 48 dB 50 dB 50 dB 50 dB
Reflection Tracking
HP 8510E Opt 005 ±0.003 dB ±0.003 dB ±0.006 dB
HP 8510SX ±0.003 dB ±0 dB ±0 dB ±0 dB
Transmission Tracking
HP 8510E Opt 005 ±0.017 dB ±0.044 dB ±0.084 dB
HP 8510SX ±0.009 dB ±0.004 dB ±0.009 dB ±0.01 dB
Crosstalk
HP 8510E Opt 005 89 dB 115 dB 110 dB
HP 8510SX 117 dB 114 dB 108 dB 95 dB
Frequency Range (GHz)
Raw (typical) 0.045-2 2-8 8-20 20-26.5
-----------------------------------------------------------------------------
Directivity
HP 8510E Opt 005 23 dB 23 dB 14 dB
HP 8510SX 24 dB 24 dB 28 dB 27 dB
Source Match
HP 8510E Opt 005 17 dB 15 dB 11 dB
HP 8510SX 23 dB 23 dB 16 dB 14 dB
Load Match
HP 8510E Opt 005 17 dB 15 dB 11 dB
HP 8510SX 23 dB 23 dB 16 dB 14 dB
Measurement Throughput Summary
The following table shows typical measurement times for an HP 8510C
system with full two-port error correction.
Number of Points
51 101 201 401 801
--------------------------------------------------------------------
Measurement1
Ramp Sweep2 270 ms 340 ms 470 ms 740 ms 1.3 s
Stepped Sweep
Avg. Factor = 1 1.25 s 2.5 s 5 s 10 s 20 s
Avg. Factor = 128 6.25 s 12.8 s 24 s 49 s 106 s
--------------------------------------------------------------------
Time Domain
conversion3 50 ms 100 ms 200 ms 400 ms 800 ms
--------------------------------------------------------------------
HP-IB Data Transfer to Computer4
Internal Format 20 ms 30 ms 50 ms 100 ms 200 ms
ASCII Format 240 ms 460 ms 900 ms 1.8 ms 3.6 ms
IEEE 754 Floating Point Format
32 bit 40 ms 40 ms 80 ms 160 ms 320 ms
64 bit 40 ms 80 ms 150 ms 300 ms 590 ms
1. Includes system retrace time, but does not include source bandwidth
times (typically 50 msec each). Time domain gating is assumed off.
2. If averaging is used, multiply the above ramp sweep measurement times
by the averaging factor to get the total time.
3. Option 010 only, gating off.
4. Measured with an HP 9000 Series 300 computer. Single point data transfers
can be accomplished in approximately 1 msec per point using fast CW mode.
General Specifications
Rear Panel Connectors
Sweep In: Input for 0 to 10 V sweep voltage from compatible
sweep oscillator
Stop Sweep: Input and output for stop sweep signal from
compatible sweep oscillator
10 MHz In: Input for external 10 MHz reference
Input Level: -10 dBm to +20 dBm, typical
Input Frequency Accuracy:±0.005% (50 ppm)
20 MHz Out: Output of internal 20 MHz reference oscillator
Frequency Accuracy: ±0.01%, typical
Analog ±10 V: Settable output voltage used for auxilliary voltage
domain measurements, or analog output for analog
recorders
Range: -9.995 to +10.000 volts
Linearity: ±0.1%, typical
Resolution: 4.88 mV, nominal
Output Impedance: 1 kohms
External Trigger: TTL input to trigger acquisition of single data point.
Delay is included to equalize the single path delay
from the test port. Data is taken on negative-going
TTL pulse.
Pulse Repetition Period: 1 msec minimum with no averaging. If averaging, add
(200 µs x averaging factor).
Pulse Width: 1 µs minimum
Environmental
Temperature
Operating Conditions: 5° to 40°C
Non-Operating Conditions: -40° to 75°C
Power
47.5 to 66 Hz: 100, 120, 200, 240 Vac, ±10%
HP 8510C: 370 VA, maximum
Test Sets: 95 VA, maximum
Weight
Net: 42 kg (92 lb)
Shipping: 52 kg (114 lb)
Ordering Information:
HP 8510C Vector Network Analyzer
For flexibility in specifying a solution that meets your exact needs, a system
can be ordered as separate line items. A complete system includes the HP 8510C
network analyzer, a test set, compatible source and measurement accessories.
Analyzer
HP
8510C Vector Network Analyzer, MHz to 110 GHz
Opt
008 Pulsed-RF Measurement Capability Requires HP 85110A
S-parameter test set Also, see HP 85108A or 85108L
Pulsed-RF Network Analyzer System
Opt
010 Add Time Domain Capability
Opt
908 Add Rack Flange Kit
Opt
913 Add Rack Flange and Handles Kit
Test
Sets (Choose One)
HP
8514B S-Parameter Test Set (45 MHz to 20 GHz)
HP 8515A S-Parameter Test Set (45 MHz to 26.5 GHz)
HP 8517B S-Parameter Test Set (45 MHz to 50 GHz)
HP 85110A Pulsed-RF S-Parameter Test Set (2 GHz to
20 GHz)
HP 85110L Pulsed-RF S-Parameter Test Set (45 MHz to
2 GHz)
HP 8511A Frequency Converter (45 MHz to 36.5 GHz)
HP 8511B Frequency Converter (45 MHz to 50 GHz)
Must
also order two test set modules for complete waveguide
S-parameter test set operation for each waveguide
band:
HP
Q85104A Test Set Module (33 GHz to 50 GHz)
HP U85104A Test Set Module (40 GHz to 60 GHz)
HP V85104A Test Set Module (50 GHz to 75 GHz)
HP W85104A Test Set Module (75 GHz to 110 GHz)
Single-Connection
Single-Sweep Millimeter-Wave Subsystem (Components
of HP 8510XF)
HP
E7342A Millimeter Subsystem 2 to 85 GHz Consists of
two 85 GHz test heads and millimeter test set controller.
Opt
005 Add 45 MHz to 2 GHz low frequency extension
Opt
006 Add RF pass thru Provides coupled output of 50
GHz source for additional test set(s). Additional
test set(s) must have Option 001 installed.
HP
E7342A Millimeter Subsystem 2 to 85 GHz Consists of
two 85 GHz test heads and millimeter test set controller.
Opt
005 Add 45 MHz to 2 GHz low frequency extension
Opt
006 Add RF pass thru Provides coupled output of 50
GHz source for additional test set(s). Additional
test set(s) must have Option 001 installed.
Sources
(Choose an HP 8360 Series Synthesized Sweeper)
HP
83651B Synthesized Sweeper (45 MHz to 50 GHz)
HP 83631B Synthesized Sweeper (45 MHz to 26.5 GHz)
HP 83621B Synthesized Sweeper (45 MHz to 20 GHz)
HP 83620B-H80 Synthesized Sweeper (45 MHz to 2 GHz)
for HP 85110L only
HP 83622B Synthesized Sweeper (20 GHz to 20 GHz) for
HP 85110A
HP 83623L Synthesized Sweeper (45 MHz to 20 GHz) for
HP 85110A
Electronic
Calibration
HP
85060C Electronic Calibration Control Unit
HP 85060A Calibration Kit, 1 to 18 GHz, 7 mm
HP 85062A Calibration Kit, 1 to 26.5 GHz, 3.5 mm
HP 85064A Calibration Kit, 1 to 18 GHz, Type-N
Mechanical
Calibration Kits
Standard
HP 85050B Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052B Calibration Kit, 0.045 to 26.5 GHz, 3.5
mm
HP 85054B Calibration Kit, 0.045 to 18 GHz, Type-N
HP 85056A Calibration Kit, 0.045 to 50 GHz, 2.4 mm
Precision
HP
85050C Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052C Calibration Kit, 0.045 to 26.5 GHz, 3.5
mm
HP 85059A Calibration Kit, 0.045 to 110 GHz, 1.0 mm
HP X11644A Calibration Kit, 8.2 to 12.4 GHz, WR-90
HP P11644A Calibration Kit, 12.4 to 18 GHz, WR-62
HP K11644A Calibration Kit, 18 to 26.5 GHz, WR-42
HP R11644A Calibration Kit, 26.5 to 40 GHz, WR-28
HP Q11644A Calibration Kit, 33 to 50 GHz, WR-22
HP U11644A Calibration Kit, 40 to 60 GHz, WR-19
HP V11644A Calibration Kit, 50 to 75 GHz, WR-15
HP W11644A Calibration Kit, 75 to 110 GHz, WR-10
Economy
HP
85050D Calibration Kit, 0.045 to 18 GHz, 7 mm
HP 85052D Calibration Kit, 0.045 to 26.5 GHz, 3.5
mm
HP 85054D Calibration Kit, 0.045 to 18 GHz, Type-N
HP 85056D Calibration Kit, 0.045 to 50 GHz, 2.4 mm
HP 85058D Calibration Kit, 0.045 to 65 GHz, 1.85 mm
Open
and Short Circuits, Fixed Terminations and In-Series
Adapters HP 85056K
Verification Kits
HP
85051B Verification Kit, 0.045 to 18 GHz, 7 mm
HP 85053B Verification Kit, 0.045 to 26.5 GHz, 3.5
mm
HP 85055A Verification Kit, 0.045 to 18 GHz, Type-N
HP 85057B Verification Kit, 0.045 to 50 GHz, 2.4 mm
HP R11645A Verification Kit, 26.5 to 40 GHz, WR-28
HP Q11645A Verification Kit, 33 to 50 GHz, WR-22
HP U11645A Verification Kit, 40 to 60 GHz, WR-19
HP V11645A Verification Kit, 50 to 75 GHz, WR-15
HP W11645A Verification Kit, 75 to 110 GHz, WR-10
Test
Port Return Cables Use these cables for applications
where the device under test is connected directly
to the test set port.
Single
Cables for HP 8514B, 8515A, 85110A and 85110L Test
Sets (3.5 mm rugged test port connector)
HP 85131C Semi-Rigid Cable, 3.5 mm (f)
HP 85131E Flexible Cable, 3.5 mm (f)
HP 85132C Semi-Rigid Cable, 7 mm
HP 85132E Flexible Cable, 7 mm
Single
Cables for HP 8517B Test Set (2.4 mm rugged test port
connector) HP 85133C Semi-Rigid Cable, 2.4 mm (f)
HP 85133E Flexible Cable, 2.4 mm (f)
HP 85134C Semi-Rigid Cable, 3.5 mm (f)
HP 85134E Flexible Cable, 3.5 mm (f)
HP 85135C Semi-Rigid Cable, 7 mm
HP 85135E Flexible Cable, 7 mm
Use
these cables for applications where the device under
test is connected between cable ends. This setup offers
more flexibility when connecting to the device under
test.
Cable
Set for HP 8514B, 8515A, 85110A and 85110L Test Sets
(3.5 mm rugged test port connector)
HP 85131D Semi-Rigid Cable Set, 3.5 mm (m and f)
HP 85131F Flexible Cable Set, 3.5 mm (m and f)
HP 85132D Semi-Rigid Cable Set, 7 mm
HP 85132F Flexible Cable Set, 7 mm
Cable
Set for HP 8517B Test Set (2.4 mm rugged test port
connector)
HP 85133D Semi-Rigid Cable Set, 2.4 mm (m and f)
HP 85133F Flexible Cable Set, 2.4 mm (m and f)
HP 85134D Semi-Rigid Cable Set, 3.5 mm (m and f)
HP 85134F Flexible Cable Set, 3.5 mm (m and f)
HP 85135D Semi-Rigid Cable Set, 7 mm
HP 85135F Flexible Cable Set, 7 mm
HP
11500I Test Port Cable, 1.0 mm (m and f)
HP 11500J Test Port Cable, 1.0 mm (m and f)
Adapters
HP 85130B Adapter Set, 7 mm
HP 85130C Adapter Set, 3.5 mm to Type-N
HP 85130D Adapter Set, 3.5 mm (m and f)
HP 85130E Adapter Set, 7 mm
HP 85130F Adapter Set, 3.5 mm (m and f)
HP 85130G Adapter Set, 2.4 mm (m and f)
HP 11904S Adapter Set, 2.92 mm, 0.045 to 40 GHz
HP V281C Adapter V-Band Waveguide, 1.0 mm (f) to V-Band
HP V281D Adapter V-Band Waveguide, 1.0 mm (m) to V-Band
HP W281C Adapter W-Band Waveguide, 1.0 mm (f) to W-Band
HP W281D Adapter W-Band Waveguide, 1.0 mm
|