Agilent HP 8593A Spectrum Analyzer kHz to 22 GHz

These portable spectrum analyzers offer frequency accuracy and a wide range of options for applications that demand higher performance. The HP 8593A has a frequency range of 9 kHz to 22 GHz or 26.5 GHz with option 026, an internal preselector, and an amplitude range of -114 to +30 dBm. (For general export, the HP 8593A option 1BH does not tune above 18 GHz nor span greater than 2.3 GHz.)These instruments have standard 7.5 ppm frequency accuracy that can be inproved with an optional precision frequency reference to marker count accuracy of ± 230 Hz at 1 GHz or ± 2.3 kHz at 18 GHz.

Specifications:

FREQUENCY
Frequency range 9 kHz to 22 GHz; 9 kHz to 26.5 GHz (option 026)
Frequency reference
Aging ± 2 X 10 -6/year
Settability ± 5 X 10-7
Temperature stability ± 5 X 10-6
Precision frequency reference (Opt 004)
Aging ± 1 X 10-7/year
Settability ± 5 X 10-8
Temperature stability ± 1 X 10-8
Frequency readout accuracy ± (frequency readout X frequency reference error + 3% of span + 20% of RBW + 100 Hz sweep time) for spans £ 10 MHz; ± (freq readout X freq ref error + 3% of span + 20% of RBW) for spans > 10 MHz
Marker count accuracy (signal-to-noise ratio) ³ 25 dB, RBW/span ³ 0.01 ± (marker freq X freq ref error + counter res + 100 Hz) spans £ 10 MHz; ± (marker freq X freq ref error + counter res + 1 kHz), spans > 10 MHz
Counter resolution Selectable from 10 Hz to 100 kHz
Frequency span
Range zero span, (10 X N) kHz to 19.25 GHz, (10 X N) kHz to 23.75 GHz (opt 026)
Accuracy ± 2% of span, span < 10 MHz; ± 3% of span, span > 10 MHz
Sweep time
Range 20 ms to 100 s, span = 0 Hz or > 10 kHz; 20 µs to 100 s, span = 0 Hz (opt 101)
Accuracy ± 3%, 20 ms to 100 s, ± 2%, 20 µs to 20 ms
Sweep trigger free run, single, line, video, external
Stability
Noise sidebands £ -95 dBc/Hz + 20 log N at > 30 kHz offset from CW signal
Comb generator 100 MHz fundamental freq; ± 0.007% freq accuracy
AMPLITUDE
Amplitude range -114 to +30 dBm
Maximum safe input level +30 dBm (1 watt, 7.1 Vrms), 0 Vdc
Gain compression £ 0.5 dB (total power at input mixer = -10 dBm)
Displayed average noise level £ 114 to < -92 dBm
Spurious responses
Second harmonic distortion < -70 dBc for -40 dBm tone at input mixer, 10 MHz to 2.9 GHz; < -100 dBc for -10 dBm tone power at input mixer or below displayed av noise lev), > 2.75 GHz
Third-order intermodulation distortion > 10 MHz < -70 dBc for two -30 dBm tones at input mixer and > 50 kHz separation
Other input-related spurious < -70 dBc for applied freq £ 18 GHz; < -60 dBc for applied freq £ 22 GHz
Display range
Log scale 0 to -70 dB from ref lev is calibrated; 1 to 20 dB/div in 1 dB steps;  divisions displayed
Linear scale 8 divisions
Scale units dBm, dBmB, dBmicroV, volts, watts
Reference level
Range -114 to +30 dBm
Resolution 0.01 dB for log scale; 0.12% of ref lev for linear
Accuracy (ref to -20 dBm ref level) ± (0.05 dB + input atten acc @ 50 MHz), 0 dBm to -59.9 dBm, ± (1.25 dB + input atten acc @ 50 MHz), -60 to -114 dBm
Frequency response (ref to 300 MHz CAL OUT, preselector peaked)
Absolute ± 2.0 to ± 3.0 dB
Relative flatness ± 1.5 to ± 2.0 dB
Calibrator output
Frequency 300 MHz ± 30 kHz
Amplitude -20 dBm ± 0.4 dB
Input attenuator
Range 0 to 70 dB in 10 dB steps
Accuracy at 50 MHz, ref to 10 dB atten + 0.5 dB, 0 to 60 dB; + 1.2 dB, 70 dB
Resolution bandwidth 1 kHz to 3 MHz, ± 20%
Switching uncertianty ± 0.4 dB, 3 kHz to 3 MHz RBW; ± 0.5 dB, 1 kHz
Video bandwidth range 30 Hz to 1 MHz
Log to linear switching + 0.25 dB at reference level
Display scale fidelity ± 0.2 dB/ 2 dB, 0 to -70 from ref lev, incremental; ± 0.75 dB, 0 to -60 dB from ref lev and ± 1.0 dB, 0 to -70 dB from ref lev, maximum cumulative

 

Ordering Information:

Agilent HP 8593A Spectrum Analyzer kHz to 22 GHz

HP 41800A Active Probes
HP 85024A High Frequency Probes

 001  - 75-ohm Input Impedeance
 004  - Precision Frequency Reference
 009  - LO OUTPUT, REAR PANEL
 010  - Tracking generator 50 Ohms
 011 - Tracking Generator 75 ohms
 021 - HP-IB Interface
 023 -  RS-232 Interface
 026  - 26.5GHz Frequency Extension.
 040 - Front Protective Cover with St
 042 - Soft Carrying Case
 0D2 - Refurbished Demo Equipment
 101 - Fast Time Domain Sweep
 102 - AM/FM Demod & TV Synch Trigger
 103 - QUASI-PEAK DETECTION
 105 - TIME GATED SPECTRUM ANALYSIS.
 110 - Demodulator Card for Measuring
 1BH - General export license version
 301 - TV Sync Trigger AM/FM Demod-Fa
 711 - 50/75 ohm Matching Pad/DC Bloc
 908 - Rack Mount Kit Without Front H
 909  - Rack Mount Kit With Front Hand
 910  - EXTRA USERS MANUAL SET.
 915  - SERVICE MANUAL SET.
 R01 -  Media Retention
 R02 -  AM/FM Demod. and TV Sync Retro
 R04  - Precision Frequency Retrofit K
 R05 - Return 8592a to SAD for Credit
 R15  - TIME GATED SPECTRUM ANALYSIS R
 R21  - GPIB Interface Retrofit Kit.
 R23  - RS-232 Interface Retrofit Kit.

 



 
 