Agilent HP 8665B High-Performance Signal Generator, 100 kHz to 6 GHz
The Agilent 8665B signal generator is suited for basic receiver testing
up to 6 GHz. With Option 004 (low-noise enhancement), it can be used for
out-of-channel receiver testing or as a clock source where having the
lowest phase jitter is important. Radar testing can be done by adding
Option 008 (pulse modulation) . Pulse width and delay can be internally
adjusted between 50 ns and 999 ns, eliminating the need for an external
pulse generator. Standard FM rates of up to 2 MHz and deviations to 20
MHz are suitable for many applications such as high-speed digital communications.
The internal modulation source generates sine, square, triangle or sawtooth
waveforms. For applications demanding the lowest RF leakage, Option 010
provides increased RF shielding.
Features:
- <-140 dBc/Hz typical SSB phase noise at 20 kHz offset at 1 GHz
with Option 004
- <-100 dBc nonharmonic spurious to 2 GHz reduces error when testing
spurious immunity of receivers
- AM, FM, and optional pulse modulation
- 0.01 Hz frequency resolution
- On-site repair and calibration
Specifications:
Range: 100 kHz to 6 GHz
Resolution: 0.01 Hz
Accuracy: Timebase stability x fc
Switching Speed: <50 ms, typical <100 ms
(Opt 004)
Sweep
Digital Sweep: Digitally stepped sweep over entire
frequency range. Linear/log selection.
0.5 to 1000 s sweeps.
Markers/Z-Axis Output: 3 markers available/Z-axis output
nominally
+5 V/X-axis output nominally 0 to 10 V.
Phase Continuous Sweep: 40 MHz of span available at maximum
carrier frequency. 20 ms to 10 s sweep times.
Spectral Purity Specifications
SSB Phase Noise @ 1 GHz (20 kHz offset):
-117 dBc/Hz; -134 dBc/Hz (Opt 004)
Nonharmonics (>10 kHz offset):
-100 dBc, 187.5 to 2060 MHz
<-90 dBc, 2060 to 6000 MHz, 0.1 to 187.5 MHz
Harmonics: <-30 dBc, output <=+10 dBm
Subharmonics: <-75 dBc, 0.1 to 1500 MHz
<-40 dBc, 1500 to 3000 MHz
<-50 dBc, 3000 to 6000MHz
Residual FM @ 1 GHz: 0.3 to 3 kHz post det. BW:
<7.5 Hz rms; <1.2 Hz rms (Opt 004)
Output Specifications
Range: +13 to -139.9 dBm
+9 dBm (Opt 008)
Resolution: 0.1 dB
Absolute Accuracy: ±1 dB, output >=-119.9
dBm,1 to 1000 MHz
±1.5 dB, output >=-119.9 dBm, 1000 to 3000 MHz
±2 dB, output >=-119.9 dBm, >3000, <1MHz
Reverse Power Protection:
0.1 to 2060 MHz; 1 W, >6000 MHz
Modulation Specifications
Amplitude Modulation
Depth (@: >=+7 dBm): 0 to 100%
Resolution: 0.1%
Bandwidth (3 dB) <=+7 dBm: dc to >10 kHz, >10 MHz
Accuracy (1 kHz rate): ±(6% of setting + 1%) up to 90% depth
Distortion (30% depth, 1 kHz rate):
<4%
Frequency Modulation
Maximum Peak Deviation: 20 MHz, 3000 to 6000 MHz
(Deviation halves per lower octave):
10 MHz, 1500 to 3000 MHz
Resolution: 2.5% of setting
Bandwidth (3 dB): dc to 800 kHz
Carrier Accuracy in FM: ±0.6% of setting
Indicator Accuracy: ±9%, <20 kHz rates
Distortion: <1%, 20 Hz to 20 kHz rates
Pulse Modulation Option 008
On/Off Ratio: >80 dB
Rise/Fall Time, 10 to 90%: <8 ns
Repetition Rate: dc to 10 MHz
Internal Width/Delay: Variable, 50 ns to 1s
Internal Modulation Source
Waveforms and Rates: Sine; white Gaussian noise
(0.1 Hz to 400 kHz);
Triangle, sawtooth, square
(0.1 Hz to 50 kHz)
Frequency Accuracy: Same as timebase
Output Level (into 66 ohms): 1 V pk
Output Resolutions: 2 mV pk
Remote Programming Specifications
Interface: HP-IB (IEEE 488.2-1987)
Control Language: HP-SL; all functions
controlled except power
IEEE-488 Functions: SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0,
DC1, DT0, C0, E2
General Specifications
Power Requirements: ±10% of 100 V, 120 V,
220 V, or 240 V; 48 to 440 Hz; 500 VA
Operational Temperature: 0 °C to 55 °C
Leakage: Conducted and radiated interference meets MIL-STD-461B
REQ2 and FTZ 1046
Calibration Interval: Recommended 3 years (MTBC)
Weight: 35 kg
Size: 177 mm H x 426 mm W x 624 mm D
(7 in x 16.8 in x 24.6 in)
Option 010 adds 35 mm (1.4 in) to D
Ordering Information:
Agilent HP 8665B High-Performance Signal Generator, 100
kHz to 6 GHz
| Agilent 8665B |
High-Performance Signal Generator, 100 kHz to 6 GHz |
| Opt 001 |
High-Stability Timebase |
| Opt 003 |
Rear-Panel Input/Output |
| Opt 004 |
Low-Noise Option |
| Opt 008 |
Pulse Modulation |
| Opt 010 |
Reduced RF leakage configuration |
| Opt 0Q8 |
Factory delivered service training |
| Opt 907 |
Front-Handle Kit |
| Opt 908 |
Rack Flange Kit |
| Opt 909 |
Front handle and rack flange kit |
| Opt 910 |
Extra Manuals |
| Opt 915 |
Add service manual |
|