Agilent 8903E

The Agilent Technologies 8903E distortion analyzer provides unparalled versatility and performance for audio measurements from 20 Hz to 100 kHz.The 8903E combines the functionality of a high performance distortion analyzer, frequency counter, ac voltmeter, dc voltmeter and SINAD meter into one compact package. (The 8903E has no source.) For ease of use, most measurements on the 8903E are made with only one or two keystrokes.

Features:
  • Measures distortion, SINAD

  • Measures true-rms ac volts, dc volts, frequency

  • rms, average, and quasi-peak detection


Specifications:


Distortion
Fundamental Frequency Range: 20 Hz to 100 kHz
Display Range: 0.001% to 100% (-99.99 to 0 dB)
Accuracy: +/- 1 dB, 20 Hz to 20 kHz; +/- 2 dB, 20 Hz to 100 kHz
Input Voltage Range: 50 mV to 300 V
Residual Distortion and Noise:(the higher of)
80 kHz BW: -80 db (0.01%) or 15 uV, 20 Hz to 20 kHz
500 kHz BW: -70 dB (0.032%) or 45 uV, 20 Hz to 50 kHz -65 db (0.056%) or 45 uv, 50 to 100 kHz
Supplemental Charateristics:
3 dB Measurement Bandwidth: 10 Hz to 500 kHz
Detection: True rms calibrated average
SINAD
Fundamental Frequency Range: 20 Hz to 100 kHz
Display Range: 0 to 99.99 dB
Residual Distortion and Noise: Same as listed under distortion
Accuracy: +/-1 dB, 20 Hz to 20 kHz; +/-2 dB, 20 Hz to 100 kHz
Input Voltage Range: 50 mV to 300 V
Supplemental Characteristics:
Detection: True rms or rms-calibrated average
Frequency Measurement
Measurement Range: 20 Hz to 150 kHz (20 Hz to 100 kHz in distortion and SINAD modes)
Resolution: 5 digits (0.01 Hz for input frequencies < 100 Hz)
Accuracy: +/- (0.004% + 1 digit)
Sensitivity: 50 mV in distortion and SINAD modes
Analyzer Input
Input Type: Balanced (full differential)
Input Impedence: 100 k ohms +/- 1% shunted by <300 pF, each side to ground. (In dc-level mode the input resistance is 101 k ohms +/-1%)
Max Input:(maximum peak input voltage, any combination of ac/dc) 42 V peak, low side to ground 425 V peak, differentially or between either input to ground
CMRR: > 60 dB, 20 Hz to 1 kHz, V(in) < 2V; > 45 dB, 20 Hz to 1 kHz; > 30 dB, 20 Hz to 20 kHz


Ordering Information:

Agilent HP 8903E 20 Hz to 100 kHz Distortion Analyzer

Agilent 8903E Distortion Analyzer
      Opt 001 Input/Output Connectors on Rear Panel Only
      Opt 010 Left Position 400 Hz High-Pass Filter
      Opt 011 Left Position CCITT Weighting Filter
      Opt 012 Left Position CCIR Weighting Filter
      Opt 013 Left Position C-Message Weighting Filter
      Opt 014 Left Position CCIR/ARM Weighting Filter
      Opt 015 Left Position "A" Weighting Filter
      Opt 050 Right Position 400 Hz High-Pass Filter
      Opt 051 Right Position CCITT Weighting Filter
      Opt 052 Right Position CCIR Weighting Filter
      Opt 053 Right Position C-Message Weighting Filter
      Opt 054 Right Position CCIR/ARM Weighting Filter
      Opt 055 Right Position "A" Weighting Filter
      Opt 8ZE Refurbished equipment
      Opt 907 Front handle Kit (5061-9689)
      Opt 908 Rack Flange Kit (5061-9677)
      Opt 909 Rack Flange Kit (5061-9683) with
      Opt yes
      Opt 910 Additional Operation and Calibration Manuals(08903-90053)and Two Service Manuals (08903-90065)
      Opt 915 Adds Service Manual (08903-90065)

 



 
 