Agilent HP 8920B RF Communications Test Set

The Agilent Technologies 8920B is a full-function test set based upon the Agilent 8920A design but with increased measurement speed, accuracy, and larger user memory (928 kbytes standard). The 8920B uses PCMCIA memory cards for data storage and radio test programs. The 8920B has the functionality, speed, and accuracy for testing land mobile radios, cellular telephones, and other communications systems while improving throughput and quality in manufacturing.


Features:

  • More than 20 complete instruments
  • Frequency range 250 kHz to 1000 MHz
  • Accuracy of stand-alone instruments
  • Flash ROM updates from front panel
  • Optional spectrum analyzer, tracking generator and adjacent channel power meter
  • Built-in IBASIC computer with PCMCIA format memory cards
  • Call processing subsystem for simplified cellular test and troubleshooting


Specifications:

Signal Generator Specifications :

Frequency Range: 250 kHz to 1 GHz
Output Level Accuracy RF In/Out Connector: +/- 1.2 dB (level greater than or equal to -127 dBm)
Output Level Accuracy Duplex Out Connector: +/- 1.0 dB (-127 to +7 dBm)
Output Level Range: -137 to -19 dBm into 50 ohms (std, other options available)
Reverse Power: 60 watts continuous, 100 watts for 10 seconds/minute
Harmonics: <- 30 dBc
Non Harmonic Spurious: <- 60 dBc (at > 5 kHz from carrier)
TDMA Signal Generator Specifications
(Agilent Technologies 8920B Option 500 or 800)
Frequency Range 824 MHz to 894 MHz
Output Level Range: RF In/Out: -22 dBm to -127 dBm Duplex Out: +4 dBm to -127 dBm
Residual Error Vector Magnitude: <3.0%
Residual Phase Error: <2.6 degrees
Residual Magnitude Error: <2.6%
IQ Origin Offset: <-30dBc within 15 degrees C of last calibration
Frequency Error: +/-4 Hz plus reference error
Audio Source Specifications

Frequency Range: dc to 25 kHz
Frequency Accuracy: 0.025% of setting
Output Range: 0.1 mV to 4 Vrms
Output Accuracy: +/- 2% of setting plus resolution
RF Analyzer Specifications

Frequency Measurement Range: 400 kHz to 1 GHz
Level Measurement Range RF In/Out:(std, other options available) 1 mW to 60W continuous 100W for 10 seconds/minute
Level Measurement Range ANT IN: -36 dBm to +20 dBm in auto-tune mode
Frequency Measurement Accuracy: +/- 1 Hz plus timebase accuracy
Power Measurement Accuracy: +/- 5% of reading +/- 0.01 mW for temperature range of 25 +/- 10 degrees C
TDMA Analyzer Specifications
(8920B Option 500 or 800)
Frequency Range: 824 MHz to 894 MHz
Input Level Range:
RF In/Out: 1 mW to 60 W (0 to +47.8 dBm)
Antenna In: -36 dBm to +16 dBm
Input Frequency Setting Error: 1 kHz
Frequency Error Accuracy: +/- 2.5 Hz plus reference accuracy
Residual Error Vector Magnitude: <1.3%
Error Vector Magnitude Measurement Accuracy: +/- 0.4% + 2% of reading
Residual Phase Error: <1.0 degree
Residual Magnitude Error: <0.9%
I/Q Origin Offset Accuracy: +/-0.5 dB for values to -40 dBc
AF Analyzer Specifications

Frequency Measurement Range: 20 Hz to 400 kHz
Frequency Measurement Accuracy: +/- 0.02% plus resolution plus reference accuracy
AC Voltage Measurement Range: 0 to 30 Vrms
AC Voltage Measurement Accuracy: +/- 3% of reading (20 Hz to 15 kHz, inputs >/= 1 mV)
DC Voltage Measurement Range: 100 mV to 42 V
DC Voltage Measurement Accuracy: +/- 1.0% of reading plus DC offset
Variable Frequency Notch Filter:
Frequency Range: 300 Hz to 10 kHz
Spectrum Analyzer Specifications (Option 102)

Frequency Range: 400 kHz to 1 GHz
Frequency Span/Resolution Bandwidth (coupled) Span Bandwidth <50 kHz 300 Hz <200 kHz 1 kHz <1.5 MHz 3 kHz <18 MHz 30 kHz >/= 18 MHz 300 kHz Plus full span capability
Display: Log 1,2,and 10 dB/div
Display Range: 80 dB
Reference Level Range: +50 to -50 dBm

 


Ordering Information:

Agilent HP 8920B RF Communications Test Set

HP 8920B-004,RF Communication Test Set

HP 8920B-004-011-012,RF Communication Test Set

HP 8920B-004-013-014-031,RF Communication Test Set

HP 8920B-1-4-13-14-102,RF Communication Test Set

      Opt 001 High Stability Time Base
      Opt 004 Tone/Digital Signaling
      Opt 006 10W to 50uw Power Measurement Range
      Opt 007 Low Level RF Power Measurements
      Opt 010 400 Hz High Pass Filter
      Opt 011 CCITT Weighting Filter
      Opt 012 4 kHz Bandpass Filter
      Opt 013 C-Message Weighting Filter
      Opt 014 6 KHz Bandpass Filter
      Opt 016 High power input option--100 Watts
      Opt 020 Radio Interface Card
      Opt 031 Delete Handle and Cover
      Opt 051 Dual-mode Real Panel Connectors
      Opt 055 Mechanical Attenuator Input Option
      Opt 0BK Manuals on both paper and CD-ROM
      Opt 0BP Operator training video tape (VHS/NTSC)
      Opt 0BQ Operator training video tape (VHS/PAL)
      Opt 0BU Additional instrument BASIC manuals
      Opt 0BZ Operator training video tape (VHS/SECAM)
      Opt 102 Spectrum Analyzer with Tracking Generator and ACP
      Opt 1CM Rackmount kit
      Opt 500 Agilent 83201B Opt 003 TDMA Cellular Adapter
      Opt 800 Agilent 83206A TDMA Cellular Adapter
      Opt 801 Adds 83206A & 83236B for IS-136 Tests
      Opt 891 Adds E8291A AMPS/TDMA PoST SW (PC)
      Opt AXK Rackmount kit, 19" x 12"

 

 



 
 