Agilent HP 8924C CDMS Mobile Station Test Set
The Agilent Technologies 8924C CDMA mobile station test set provides
the key set of measurements to manufacture high quality dual-mode
CDMA mobile telephones in a single box. Acting as a calibrated,
high-performance CDMA base station, the 8924C verifies not only
the parametric performance, but also the functional aspects of phone
performance. The 8924C is optimized to provide high accuracy measurements
with the speed required for efficient manufacturing. These characteristics
result in superior performing CDMA mobiles that cost less to manufacture.
In addition to its CDMA functionality, the 8924C includes full AMPS,
NAMPS, and TACS analog phone test capability. With the 8924C, you
save space and cost by making both analog cellular and CDMA digital
cellular measurements with the same box.
Features:
- High accuracy and speed for manufacturing test
- Analog and IS-95 CDMA digital phone test capability
- Both functional and parametric phone testing
- CDMA base station simulator
Specifications:
Signal Generator (Analog Mode)
RF Frequency Range: 250 kHz to 1000 MHz
Output RF In/Out Connector Level Range: -137
to -9 dBm into 50 ohms Level Accuracy: +/- 1.2 dB (level
>/= -127 dBm) Reverse Power: 6 watts continuous Duplex
Out Connector Level Range: -127 to +7 dBm into 50 ohms
Level Accuracy: +/- 1.0 dB Reverse Power: 200 mW maximum
RF Analyzer (Analog Mode)
Frequency Measurement Range: 400 kHz to 1000 MHz RF Power
Measurement (RF In/Out connector only.) Frequency Range:
30 MHz to 1000 MHz Measurement Range: 0.1 mW to 6 W continuous
Accuracy: +/- 5% of reading +/- 0.01 mW from 15 degrees C
to 35 degrees C
AF Analyzer (Analog Mode)
Frequency Measurement Measurement Range: 20 Hz to
400 kHz Accuracy: +/- 0.02% + resolution + reference oscillator
accuracy AC Voltage Measurement Measurement Range:
0 to 30 Vrms Accuracy: (20 Hz to 15 kHz, >/= 1mV):+/- 3%
of reading SINAD Measurement Fundamental Frequency Range:
300 Hz to 10 kHz +/- 5% Accuracy: +/- 1 dB for frequencies
from 300 to 1500 Hz
CDMA Call Processing Functionality (CDMA Mode)
Service Option Modes: Service Option 001, Service Option
002, and echo mode (voice loopback from test set) Call Control:
BS call originate, BS call disconnect, MS call originate, MS call
disconnect Call Status Indicators: Transmitting, Page Sent,
Access Probe Received, Connected, Softer Handoff, Harder Handoff
Handoff Capabilities: Hard handoff and softer handoff Paging
Channel User Settable Parameters: Slotted or non-slotted operation,
half or full data rate, and SLOT-CYCLE-INDEX
CDMA Signal Generator (CDMA Mode)
CDMA Channels: Additive White Gaussian Noise Sector
A includes the following channels: Pilot Channel, Sync Channel,
Paging Channel, Traffic Channel, and OCNS Channel Sector B includes
the following channels: Pilot Channel, Traffic Channel, and
OCNS Channel Frequency Range: 501 MHz to 1000 MHz Composite
Signal Output Level Range: RF In/Out: -127 dBm/1.23 MHz
to -20 dBm/1.23 MHz Duplex Out: -127 dBm/1.23 MHz to -4 dBm/1.23
MHz
CDMA Analyzer (CDMA Mode)
CDMA Average Power Measurement Input Frequency Range:
30 MHz to 1000 MHz Measurement Range: -10 dBm to +40 dBm,
RF In/Out only CDMA Channel Power Measurement Measurement
Range: -50 to +10 dBm/1.23 MHz CDMA Modulation Measurement
Input Frequency Range: 4 MHz to 1000 MHz CDMA Frame Error
RateMeasurement Method: Data loopback per Service Option
002 supporting confidence limits Data Rates: full, half,
quarter, and eighth
Ordering Information:
Agilent HP 8924C CDMA Mobile Station Test Set
| Agilent 8924C |
CDMA Mobile Station Test Set |
| Opt 001 |
Adds E8290A PoST Software (PC based) |
| Opt 011 |
ETACS CCITT Internal Filter |
| Opt 0B1 |
Assembly Level Repair Manual |
| Opt 0BW |
Service documentation, assembly level |
| Opt 0Q8 |
Factory delivered service training |
| Opt 8ZE |
Refurbished equipment |
|