Agilent HP 89441A Vector Signal Analyzer with W-CDMA Capability, DC to 2.65 GHz

The Agilent 89441A covers baseband through RF frequencies of dc to 2.65 GHz in scalar and vector analysis modes. The scalar RF instrument mode allows full-frequency coverage in spans to 2648 MHz.

Vector RF mode offers exceptional speed and additional signal processing for enhanced time-domain characterization and demodulation. Vector spans as wide as 7 MHz can be selected anywhere in the 2.65 GHz frequency range. A vector baseband mode is also available to provide all of the features and functionality of the 89410A. In vector RF mode, both phase and amplitude characteristics are captured in the time-series data. This information can be processed for narrow resolution spectrum analysis, AM/FM/PM demodulation, time selective analysis, vector modulation analysis (optional), and many other types of measurements.

Features:

  • dc to 2.65 GHz frequency range
  • Scalar and vector analysis modes
  • Full frequency coverage in spans to 2648 MHz
  • Exceptional speed and additional signal processing in RF mode for enhanced time-domain characteristics and demodulation
  • Vector RF mode captures phase and amplitude characteristics in time-series data
  • Optional digital radio and digital video demodulation

Specifications:


Agilent HP 89400 Vector Signal Analyzer Family
Summary Specifications

The following specifications apply to the HP 89410A and 89441A.
Specifications unique to either model are listed separately


Baseband Frequency Range:

dc to 10 MHz

Baseband Frequency Span:

1 Hz to 10 MHz

Baseband Absolute Accuracy (full scale):

±0.5 dB

Baseband Channels:

1 std; 2 opt.

Baseband Source:

dc to 10 MHz

Source Types:

Arb, sine, random noise, chirp

Analog Demodulation:

AM, FM, PM

Digital Demodulation (opt):
(all formats continuous or bursted)

BPSK, QPSK, OQPSK, DQPSK, pi/4 DQPSK, 2FSK, 4FSK, 8PSK, 3pi/8 8PSK, (G)MSK, 16QAM, 32QAM, 64 QAM, 256QAM, 8VSB, 16 VSB, OFDM

Demod. Measurements & Displays (opt):

Polar (vector), constellation, I/Q eye, trellis, EVM, EVM spectrum, mag/phase error, I/Q error, error summary, symbol table

Adaptive Equalization (opt):

Adj. length, with display of derived filter and channel characteristics.

Display Update Rate:

Up to 60/second

Real-time Bandwidth:

10 MHz time capture, 78 kHz continuous

Time Capture Memory:

64 ksamples (1 Msamples opt.)

Marker Functions:

Peak track, frequency counter, band power, peak/avg. power ratio, peak & avg. power

Power Measurement:

Spectrum (with gating & band power markers) Signal envelope, C/N, C/No, PDF, CCDF




Agilent HP 89441A Summary Specifications
(in addition to family specifications above)

RF Frequency Range:

2 MHz to 2650 MHz

RF Frequency Span, Scalar:

1 Hz to 2650 MHz

RF Frequency Span, Vector:

1 Hz to 7 MHz (8 MHz opt.)

Phase Noise:

-116 dBc/Hz (10 kHz offset, Fin=1 GHz) -124 dBc/Hz typ.

Input Range:

-50 dBm to +25 dBm

Input Impedance:

50 Ohms

RF Absolute Accuracy (full scale):

±2.0 dB (±0.5 dB typ.)

RF Source (opt):

2 MHz to 2650 MHz



Ordering Information:

Agilent HP 89441A Vector Signal Analyzer with W-CDMA Capability

Agilent 89441A DC to 2.65 GHz Vector Signal Analyzer
      Opt 100 CDMA Analysis Bundle (Opt AY9, AYA, B73, and B79)
      Opt 1BH Limit the maximum real-time bandwidth to 25.6 kHz
      Opt 1BP Standards compliant calibration certificate and test data
      Opt 1C2 Instrument BASIC
      Opt 1D7 50 to 75 Ohm minimum loss pad
      Opt 1F0 External PC-style U.S. ASCII keyboard
      Opt AX3 Front Handle Kit
      Opt AX4 Rack Flange Kit
      Opt AX5 Front Handle Kit and Rack Flange Kit
      Opt AY4 Delete the standard High Precision Frequency Reference oscillator
      Opt AY7 Add a full second 10 MHz input channel
      Opt AY8 Add an Internal RF Source
      Opt AY9 Extend time capture memory to 1 MSample
      Opt AYA Add Vector Modulation Analysis and adaptive equalization
      Opt AYB Add Waterfall and Spectrogram
      Opt AYH Vector Modulation Analysis of 16,32,64 and 256QAM digital video signal formats
      Opt AYJ Add adaptive EQ to modulation analysis
      Opt B73 W-CDMA code domain power for experimental system
      Opt B79 Code domain power & modulation analysis
      Opt B7A Enhanced data rates for GSM evol
      Opt UFG Adds 4Mb RAM and LAN interface
      Opt UG7 Remote displays using X11 Windows and FTP
      Opt UK6 Commercial Calibration with Test Data

 

 



 
 