Agilent HP E1440A VXI21 MHz Synthesized Function/Sweep Generator

The Agilent E1440A function/sweep generator is a C-size, 2-slot, message-based VXI module. It provides low-distortion sinewaves and a variety of waveforms for applications requiring high frequency stability and resolution (11 digits). A programmable relative phase output synchronized to a companion module is also available. Two or more E1440A modules can be used for generating multi-phase related signals.

With this module, you can use the modulation source as an arbitrary function generator via GPIB to provide user-defined waveforms, or use the save-recall memory that includes nonvolative memory locations for simple and rapid access to frequently used test setups. Additionally, you can produce five different waveforms including: sine, square, triangle, negative, and positive ramps.

Features:

  • Five different waveforms
  • Multi-interval sweep and multimarker mode
  • Amplitude and phase modulation
  • 1 µHz - 60 MHz TTL clock
  • High-voltage output option, Isolated (floating) outputs
  • Two or more HP E1440A modules for generating phase-related signals

Specifications:

Waveforms

sine, square, triangle, negative and positive Ramps, dc, TTL clock

Frequency Range
Sine: 1 µHz - 21 MHz Square: 1 µHz - 11 MHz Triangle: 1 µHz - 11 kHz Ramps: 1 µHz - 11 kHz TTL clock: 1 µHz - 60 MHz Resolution: 11 digits Accuracy: ±5 ppm of selected value, 20 to 30°C, at time of calibration with standard frequency reference Stability: ±5 ppm/year, 20 to 30 °C Modulation: AM, PM

Main Signal Output (Typical)
Impedance: 50 Ohm ±1 Ohm Maximum voltage: 42 V pk (AC+DC) (chassis ground to circuit ground, 0 - 10 kHz) Maximum voltage: ±10 V (floating ground to signal output) Connector: BNC

Amplitude
(50 ohm all waveforms except TTL clock, without DC offset) Range: 1 mV to 10 Vp-p in 8 amplitude ranges, 1-3-10 sequence, amplitude can also be set up in Vrms and dBm Resolution: 4 digits (0.03% of full range) Amplitude Accuracy: ±2% FS

Sinewave Spectral Purity
Phase noise: -55 dB for a 30 kHz band centered on a 20 MHz carrier (excluding ±1 Hz about the carrier) Spurious: -60 dBc or -85 dBm, whichever is greater Sinewave harmonic distortion: Frequency Range Harmonic Level 0.1 Hz - 199 kHz -60 dBc 200 kHz - 1.99 MHz -40 dBc 2 MHz - 14.9 MHz -30 dBc 15 MHz - 20 MHz -25 dBc

Squarewave Characteristics (Typical)
Rise/fall time: <=20 ns (10% to 90% of p-p output voltage) Overshoot: 5% of p-p amplitude at full output Triangle/ramp linearity: ±0.05% of full p-p output voltage for each range (10% - 90%, 10 kHz)

DC Offset Range (50 ohm)
DC only: 0 to ±5 V DC + AC: max. ±4.5 V Resolution: 4 digits

Phase Offset
(related to other Agilent E1440A or equivalent) Range: ±719.9° Resolution: 0.1° Increment accuracy: ±0.5° Stability: ±1° of phase / °C

Sinewave Amplitude Modulation (Typical)
Modulation depth: 0 - 98% Modulation frequency range: DC to 350 kHz (1 µHz - 21 MHz carrier frequency) Envelope distortion: -30 dB for modulation to 80% at 1 kHz (0 Vdc Offset) Sensitivity: ±5 V peak for maximum modulation

Phase Modulation (Typical)
Sinewave range: ±900°, ±5 V input Sinewave linearity: ±0.5%, best fit straight line up to ±720° of modulation range Squarewave range: ±450° Triangle range: ±45° Positive and negative ramps range: ±90° Modulation frequency range: DC to 5 kHz

Frequency Sweep
Sweep sequence modes: single, continuous Sweep function modes: Multi-Interval: (up to 50 different intervals can be sequenced and repeated in any order in a sequence that can contain up to 100 intervals) Linear or logarithmic sweep: (can be set for each interval) Sweep time: Linear: 0.01 s to 105 s Logarithmic: 0.1 s to 105 s Minimum sweep width: Linear: 0 Hz Logarithmic: 1 decade Maximum sweep width: full frequency range Minimum sweep rate: Linear: 0.2 Hz/s Phase continuity: sweep is phase continuous over the full frequency range of the main output for all sweep modes Multimarker: Linear sweep only: up to nine markers can be set in this one dedicated interval Sweep time: 0.01 s to 105 s Sweep width: from 0 Hz to full frequency range

Auxiliary Outputs(Typical)
SYNC-OUT TTL: Signal: Phase synchronous squarewave with same frequency as the main signal output, or 1 µHz to 60 MHz TTL clock (main signal output switched off) Output impedance: 50 ohm Connector: BNC and TTL trigger bus X-Drive 0 to 10 V: Signal: 0 - 100 s sweeps only (proportional ramp to the entire sweep time) Output impedance: 650 ohm Output level: 0 to + 10 V (into open circuit) Connector: BNC Pen lift: Signal: TTL-compatible voltage levels capable of sinking current from a positive source. Current 200 mA, voltage 45 V Connector: BNC Marker TTL: Signal: High-to-low transitions at selected marker frequencies. TTL- and CMOS-compatible output levels Pulsewidth in multimarker mode: 1 ms Connector: BNC and TTL trigger bus Fan out: 4 REF out 10 MHz Signal: 10 MHz squarewave for phase-locking additional instruments to the Agilent E1440A. Output impedance: 50 ohm Output levels (into 50 ohm): high level >2 V, low level <0.2 V AC-coupled output levels: 10 dBm Connector: BNC

Auxiliary Inputs (Typical)
External REF in 1/10 MHz: (For phase-locking the Agilent E1440A to an external frequency reference) Signal: from 0 dBm to 20 dBm into 50 ohm (reference signal must be a subharmonic of 10 MHz from 1 MHz to 10 MHz) Connector: BNC or VXI-system clock AM: Input impedance: 10 kOhm Connector: BNC Max. external voltage: ±15 V PM: Input impedance: >40 kOhm Connector: BNC Max. external voltage: ±15 V

Option 001 High-Voltage Output
Frequency range: 1 µHz to 1 MHz Amplitude: Range: 4 mV to 40 V p-p in eight ranges, 4-12-40 sequence into 500 ohm, <500 pF load; ranges are four times the standard instrument ranges, without DC offset Accuracy: ±2% of full output for each range at 2 kHz Flatness: ±10% relative to programmed amplitude Sinewave harmonic distortion: Frequency Range Harmonic Level 10 Hz - 199 KHz - 60 dBc 200 kHz - 1 MHz - 40 dBc Output impedance: <3 ohm at DC, <10 ohm at 1 MHz (load impedance 500 ohm, 500 pF, max. output current 40 mA peak) DC offset range: four times the specified range of the standard instrument

VXI Characteristics
VXI device type: Message-based Data transfer bus: A16/24, D16 Master, A16/D16 Slave Size: C Slots: 1 Connectors: P1/2 Shared memory: n/a VXI busses: TTL Trigger Bus (T) C-size compatibility: Yes

Command module firmware: n/a Command module firmware rev: n/a I-SCPI Win 3.1: n/a I-SCPI Series 700: n/a C-SCPI LynxOS: n/a C-SCPI Series 700: n/a HP VEE Drivers: n/a VXIplug&play Win Framework: Yes VXIplug&play Win95/NT Framework: Yes VXIplug&play HP-UX

Ordering Information:

Agilent HP E1440A VXI 21 MHz Synthesized Function/Sweep Generator

Agilent E1440A VXI 21 MHz Synthesized Function/Sweep Generator
      Opt 001 High voltage output
      Opt 0B1 Add manual set
      Opt 0B2 Operation manual
      Opt 0B3 Service manual

 

 



 
 