Agilent HP E4400A Analog RF Signal Generator, 250 kHz to 1000 MHz

The new Agilent ESG-1000A (HP E4400A) analog RF signal generator offers excellent in-channel performance with superior quality and reliability -- at an affordable price. The first in a new generation of signal generators, it provides excellent frequency and level control, and wide modulation capabilities. It is ideally suited to meet the demanding requirements of today's receiver test, component test and local oscillator applications. The innovative design of the new Agilent ESG-1000A (HP E4400A) provides a flexible architecture that can be tailored to meet the changing demands of evolving markets. Lower initial cost, high reliability and a two-year calibration cycle, all strive to minimize the cost of ownership. The Agilent ESG-1000A (HP E4400A) RF signal generator is designed for long-term dependability, which maximizes production throughput and uptime.


Features

  • 250 kHz up to 1 GHz
  • Flexible architecture, upgrade paths for options, and digital
  • Electronic attenuator for reliability & repeatability
  • Superior level accuracy
  • Wideband FM and Phase Modulation
  • Step sweep (frequency, power and list)
  • Built-in function generator

Specifications

Frequency Range Agilent ESG-1000A: 250 kHz to 1000 MHz
Resolution: 0.01 Hz
Switching Speed Modulation On: <45 ms, typical Modulation Off: <35 ms, typical
Accuracy: Same as timebase

Sweep Modes

Operating modes Step: frequency & power, and arbitrary list
Dwell Time: 2 ms to 60 sec
Number of Points: 2 to 401

Internal Reference Oscillator

Stability ----------------------------------------------------------------------
Standard (typical)
High Stability (Opt 1E5)
Aging Rate <±2 ppm/yr <±0.1 ppm/yr or <± 0.0005 ppm/day after 45 days
Temperature <±1 ppm <±0.05 ppm, typical (0 ° to 55 °C)
Line Voltage <±0.1 ppm <±0.002 ppm, typical (+5%, -10%) (+5%, -10%) ----------------------------------------------------------------------
Timebase Reference Output Frequency: 10 MHz Amplitude: >0.35 Vrms into 50 ohm load
External Reference Input Frequency: 1, 2, 5, 10 MHz ± typ. 10 ppm Option 1E5: 1 ppm, typical Amplitude: >0.15 Vrms Input Impedance: 50 ohm

Output

Range 250 kHz to 1000 MHz: +13 to -136 dBm
Resolution 0.02 dB
Level Accuracy1 (at 23 ±5°C) +7 to -127 dBm <-127 dBm 250 kHz to 1 GHz: ±0.5 dB ±1.5 dB
Attenuator Hold Level Range: >17 dB
Switching Speed: <25 ms typical With Power Search Mode: <210 ms typical
Reverse Power Protection: 250 kHz to 1000 MHz: 50 Watts Max dc Voltage: 50 V
SWR (typical) 250 kHz to 1000 MHz: <1.4:1
Output Impedance: 50 ohms 1Accuracy degrades by 0.02 dB/°C over full temperature range and by 0.3 dB above + 7 dBm.

Frequency Bands
----------------------------------------------------------------------
Band
Frequency Range
N# 1 250 kHz to <=249.999 MHz 1 2 >249.999 to <=500 MHz 0.5 3 >500MHz to <=1 GHz 1 ----------------------------------------------------------------------

Spectral Purity

SSB Phase Noise (typical,at 20 kHz offset) at 500 MHz: <-120 dBc/Hz at 1000 MHz: <-116 dBc/Hz
Residual FM (CW mode, 0.3-3 kHz BW,CCITT, rms): Phase Noise Mode l: <N x 2 Hz Phase Noise Mode 2: <N x 4 Hz
Harmonics <=+4 dBm output level: <-30 dBc
Nonharmonics (>3 kHz offset, <+7 dBm output level) 250 kHz to 1000 MHz: <-65 dBc
Subharmonics <=1000 MHz: None

Frequency Modulation

Maximum Deviation: N x 10 MHz
Resolution: 0.1% of deviation or 1 Hz, whichever is greater
Deviation Accuracy(1 kHz rate, dev. <N x 100 kHz): <±(3.5% of FM deviation + 20 Hz)
Modulation Frequency Response(deviation = 100 kHz) ---------------------------------------------------------------------
Path
Rates
1 dB Bandwidth
3 dB Bandwidth, typical
FM1 dc/20 Hz to 100 kHz dc/5 Hz to 10 MHz
FM2 dc/20 Hz to 100 kHz dc/5 Hz to 1 MHz ---------------------------------------------------------------------
Distortion (1 kHz rate, THD, dev. = N x 100 kHz): <1%

Phase Modulation

Maximum Deviation: N x 90 radians
Resolution: 0.1% of set deviation
Deviation Accuracy (1 kHz rate): <±(5% of deviation +0.01 radians)
Modulation Frequency Response ----------------------------------------------------------------------
PM Mode
Maximum
Rates (3 dB BW)
Deviation
PM1
PM2
Normal BW N x 90 rad dc to 100 kHz dc to 100 kHz
High BW N x 2 pi rad dc to 1.5 MHz (typ) dc to 1 MHz (typ) N x pi/2 rad dc to 4 MHz (typ) dc to 0.9 MHz (typ) ----------------------------------------------------------------------
Distortion (1 kHz rate, THD, dev <N x 90 rad): <1%

Amplitude Modulation fc>500 kHz

Range(envelope peak <=max specified power): 0 to 100%
Resolution: 0.1%
Rates (3 dB Bandwidth): dc/10 Hz to 10 kHz
Distortion(1 kHz rate, THD) 30% AM: <1.5% 90% AM: <4%
Accuracy(1 kHz rate): <±(5% of setting + 1%)

Pulse Modulation

On/Off Ratio <=1 GHz: >80 dB
Rise/Fall Times: 150 ns, typical
Minimum Width (typical) ALC On: 2 µs ALC Off: 0.4 µs
Pulse Repetition Frequency (typical) ALC On: 10 Hz to 250 kHz ALC Off: DC to 1.0 MHz
Level Accuracy (relative to CW): ± 0.5 dB, typical
Internal Pulse Generator (Squarewave only) Squarewave Rates: 0.1 Hz to 50 kHz Pulse Period: 16 µs to 30 seconds Width: 8 µs to 30 seconds Resolution: 4 µs

Internal Modulation Source
Provides FM, PM,and AM Modulation Signals and LF Out
Waveforms: sine, square, ramp, triangle, pulse, noise
Rate Range: Sine: 0.1 Hz to 50 kHz Square, Ramp, Triangle: 0.1 Hz to 10 kHz
Resolution: 0.1 Hz Pulse: 4 µs
Frequency Accuracy: 0.005%
Swept Sine Mode(Frequency, Phase Continuous):
Operating Modes: Triggered or Continuous Sweeps
Frequency Range: 0.1 Hz to 50 kHz
Sweep Time: 1 ms to 65 seconds
Resolution: 1 ms
Dual Sinewave Mode
Frequency Range: 0.1 Hz to 50 kHz
Amplitude Ratio: 0 to 100%
Amplitude Resolution: 0.1%

LF Out (Internal Modulation Source)

Amplitude: 0 to 3 Vpeak into 50 ohms
Output Impedance: <1 ohm

External Modulation Inputs

Modulation Types: Ext1: FM, PM, AM, and Burst Envelope Ext2: FM, PM, AM, and Pulse
Simultaneous Modulation All modulation types may be simultaneously enabled, except: FM with PM, AM with Burst. AM, FM, and PM can sum simultaneous inputs from any two sources (INT,EXT1, and EXT2.) Any given source (INT, EXT1, or EXT2) may only be routed to one activated modulation type.

Remote Programming

Interface: HP-IB (IEEE-488.2-1987) with Listen and Talk, RS-232
Control Languages: SCPI version 1992.0, also compatible with Agilent 8656B & 8657A/B/D/J mnemonics
Functions Controlled: All front panel functions except power switch and knobs
IEEE-488 Functions: SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT0, C0, E2

General


Power Requirements: 90 to 254 V; 50,60, or 400 Hz; 200 W maximum
Operating Temperature Range: 0 to 55° C
Leakage: Conducted and radiated interference meets MIL-STD-461B RE02 Part 2 and CISPR 11
Storage Registers: Up to 100 storage registers, up to 10 sequences available
Weight:  <12.7 kg (28 lb) net, <21 kg (46 lb.) shipping
Dimensions: 133 mm H x 426 mm W x432 mm D (5.25 in H x 16.8inW x 17 in D)


Specs

Ordering Information

Agilent HP E4400A Analog RF Signal Generator, 250 kHz to 1000 MHz

      Opt E4400A HP ESG-1000A Analog Signal Generator, 250 kHz to 1000 MHz
      Opt 1CM Rackmount Kit, P/N 5063-9214
      Opt 1CN Front Handle Kit, P/N 5063-9227
      Opt 1CP Rackmount Kit with Handles, P/N 5063-9221
      Opt 1E5 Add High Stability Timebase
      Opt 1EM Move Connectors to Rear Panel
      Opt OB0 Delete the Standard Manual Set
      Opt OB1 Extra Manual Set
      Opt OBV Add Service Manual (Component Level)
      Opt OBW Add Service Manual (Assembly Level Repair)
      Opt OBX Add Service Manual (Assembly and Component Level)

 



 
 