California Instruments 2750L-BTS Ballast Test System, 3000VA
The L Series consist of a range of AC Power Source products with output
power levels from 833 VA to 30 kVA. Using high frequency PWM technology,
these units provide precision AC power in single, dual (split) or three
phase configurations.
All L Series units use dual voltage ranges and programmable current limits
to protect the unit under test. Standard voltage ranges of 135 and 270
Volt rms are typical but optional output range options offer voltage ranges
up to 400 V rms. The complete solid state, high switching speed PWM architecture
of the L Series ensures low noise and low distortion output over a wide
range of power levels.
Controller Capabilities
The L Series uses a modular plug-in controller approach (except for -HGA
controller type) that enables several controllers with different feature
levels to be selected. For simple manual operation, the -M controller
provides rotary knobs for setting voltage and frequency. Both front panel
and computer control is available using one of the -P, -PT or -HGA controller
options. Units equipped with -P, -PT or -HGA controller options also offer
built in measurement functions. The following controller options are available
for the L Series.
| Controller type |
Frequency range* |
Special features
|
| -M |
45 Hz - 5000 Hz or
45 Hz - 2000 Hz |
Manual controls
|
| -P |
45 Hz - 5000 Hz |
± 0.05 % FS RMS load regulation
Transient generation
|
| -PT |
45 Hz - 550 Hz |
Fast settling time, average
response load regulation.
Transient generation
|
-HGA
(external 3.5 inch height chassis,
not a plug in)
Note: Not available for all L Series
models. Contact sales department
for configuration details. |
45 Hz - 66 Hz |
Arbitrary waveform
generation and harmonic
analysis
|
All programmable controllers offer output measurement functions for voltage,
rms current, power, power factor, phase (three phase systems) and frequency.
Three phase models can be used in single phase mode by adding the -MODE
option which allows automatic switching between single and three phase
modes from both the front panel and the IEEE-488 bus.
Programmable controllers also include a standard IEEE-488 remote control
interface and a Windows Graphical User Interface (GUI) for PC control.
The -HGA controller offers both IEEE-488 and RS232C and is supplied with
a Windows GUI program as well. This saves the end user from having
to develop his own program and makes routine tasks like running product
test sequences simple.
Features
á Single phase, three phase and split phase configurations
á Mode option allows switching between single and three phase output
á Output frequency range up to 5000 Hz.
á Full output VA with 0 to 1 power factor
á High peak current capability with up to 9:1 crest factor
á Panel height between 5.25" and 31.5" based on power level
á Efficiency 75% typical or better. Generates less heat and consumes less
power
á Abbreviated Plain English (APE) programming language support and free
Windows application software
á Optional MIL-STD704 and RTCA-DO160C test firmware
Applications
The extended output frequency range of 17 Hz to 5000 Hz (-P Controller
only with certain models) makes the L Series suitable for both commercial
and avionics applications. Dual voltage ranges provide maximum output
current at any programmed voltage up to 400 Volt. (-EHV option, some options
are mutually exclusive) The built in measurement functions often eliminate
the need for additional test equipment. Due to the many configuration
possibilities of the L Series family of products, California Instruments
is able to supply systems that specifically meet your application requirements.
The L Series offers many options and configuration choices, some of which
affect output ranges. Contact factory for configuration information.
Remote Control
All L Series AC sources shipped with a programmable controller (-P, -PT
or -HGA) include a Windows Graphical User Interface (GUI) program.
The GUI supports all functions and capabilities of the L Series controller
used. The following tasks can easily be performed through this graphical
user interface using either the IEEE-488 or RS232C (HGA controller only)
interface:
á Control all output parameters such as voltage, current limit, phase
and frequency.
á Compile lists of transient programs on disk for quick recall and execution
á Measure and record key output parameters such as volt rms, current,
peak current, real power, and power factor.
á Run RTCA/DO160C (requires option -160) or MIL-STD 704D tests (requires
option -704)
á Define custom waveforms by specifying their harmonic content (HGA only)
á Define custom waveforms by free-hand drawing with the mouse (HGA only)
á Analyze harmonic content of both voltage and current (HGA only)
á Monitor remote control commands over the bus using the built in command
viewer window to quickly learn how to program the L Series yourself.
Of course, drivers for popular programming environments such as LabView
are available as well for custom software development. If needed,
the front panel can be locked out to prevent operator intervention during
test runs.
Specifications
| Specification |
Standard Programmable
Type -P |
Transient Programmable
Type -PT |
Manual Control
Type -M
|
Voltage
Ranges |
Standard 0 - 135 V or 0 - 270 V.
All voltages are L-N.
Programmable range change included.
Program different amplitudes each phase. |
Standard 0 - 135 V or 0 - 270 V.
All voltages are L-N.
Programmable range change included.
Program different amplitudes each phase. |
Variable POT control from 0 to FS.
Optional (-RPV) 0 to FS based on 0 - 10 VDC input.
Switchable range change included.
|
Voltage
Accuracy |
TRMS Sense:
±0.135 V from 5 V to 135 V
±0.54 V from 135 V to 270 V
All at 25¡C ±1¡C
(based on TRMS reading). |
±0.7% FS from 5% FS to FS
Constant line, load and temperature at 25¡C ±1¡C. |
Variable control.
(Analog meter indication)
|
Load
Regulation |
TRMS sense: ±0.05% FS,
no load to full load. |
-0.5% FS: 45 Hz - 100 Hz
-2.0% FS: 100 Hz - 550 Hz |
±0.05%: 45 Hz to 5 kHz
|
Line
Regulation |
±0.02% FS for ±10% line change |
±2% of full output for a ±10% line change |
±0.02% of full output for a ±10% line change
|
Stability
(Amplitude) |
±0.015% FS over 24 hours at constant line,
load and temperature. |
±0.25% FS over 24 hours at constant line,
load and temperature. |
±0.015% FS over 24 hours at constant line,
load and temperature.
|
| Default Voltage |
0.0/5.0 volts (field selectable) |
0 volts |
N/A
|
Frequency
Range* |
2750L-1P, 4500L-1P & all multi-box systems:
45 Hz to 2 kHz
-3P & 751L/1501L/20010L: 45 Hz to 5 kHz
6000L-1P, 12000L-1P: 45 Hz to 440 Hz |
All models except 6000L and 12000L: 45 to
550 Hz
6000L, 12000L: 45 to 440 Hz |
2750L-1M, 4500-1M & all multi-box systems:
45 Hz to 2 kHz
-3M & 751L/1501L/20010L: 45 Hz to 5 kHz
6000L, 12000L: 45 Hz to 440 Hz
|
Frequency
Resolution |
0.01 Hz: 45 Hz to 99.99 Hz
0.1 Hz: 100 Hz to 999.9 Hz
1 Hz: 1000 Hz to 5000 Hz |
0.01 Hz: 45 Hz to 99.99 Hz
0.1 Hz: 100 Hz to 550 Hz |
3 digit resolution
|
Frequency
Accuracy |
±0.001% of programmed value |
±0.001% of programmed value |
±0.005% of set value
|
Default
Frequency
(Initial Value) |
Any (within range) |
Any (within range) |
Setting
|
| Ext. Sync Input |
TTL level |
TTL level |
N/A
|
External
Amplitude
Modulation |
N/A |
0 to 5 V RMS signal generates 0 to 11% amplitude
modulation of output voltage.
45 Hz to 5 kHz signal |
0 to 5 V RMS signal generates 0 to 11% amplitude
modulation of output voltage.
|
Phase Angle
Programming |
Phases B and/or C relative to Phase A: 0 to
±360.0¡ in 0.1¡ increments |
Phases B and/or C relative to Phase A: 0 to
±360.0¡ in 0.1¡ increments |
N/A
|
Phase
Accuracy |
±2¡ |
±2¡ |
±3¡
|
Distortion
(45 Hz - 550 Hz) |
N/A |
0 to 20% THD with sine waveform and 1% resolution |
N/A
|
| Settling Time |
16 mSec no-load,from 5V to 2% of final value;
16 mSec, full-load,to 15% of final value. |
0.5 mSec |
N/A
|
| Current Limit |
Adjustable trip Adjustable trip
Adjustable hold-off |
Adjustable fold back with recovery
|
| Remote On/Off |
Contact closure turn off |
Contact closure trip off |
Contact closure turn off
|
| Model |
Total Power
35¡ C 1 |
Output
(Phase) 2 |
Total Current Rating on 135 V RNG |
3 pH
A rms/pH |
Size/Weight 6
|
| A rms |
A peak 3 |
A peak 4
|
| 751L |
833 VA |
1 |
6.1 |
55.6 |
6015 |
n/a |
A
|
| 1501L |
1,667 VA |
1 |
12.3 |
55.6 |
6030 |
n/a |
A
|
| 1503L |
1,667 VA |
3 |
12.3 |
27.8 |
30 |
4.1 |
A
|
| 2001L |
2,000 VA |
1 |
14.8 |
55.6 |
60 |
n/a |
A
|
| 2750L |
3,000 VA |
1/3 |
22.2 |
83.3 |
90 |
7.4 |
B
|
| 4500L |
5,000 VA |
1/3 |
37 |
83.3 |
90 |
12.3 |
B
|
| 6000L |
6,000 VA |
1/3 |
44.4 |
157.4 |
170 |
14.8 |
B
|
| 9000L |
10,000 VA |
1/3 |
74 |
166.6 |
180 |
24.7 |
C
|
| 12000L |
12,000 VA |
1/3 |
90 |
314.8 |
340 |
30 |
C
|
| 13500L |
15,000 VA 5 |
1/3 |
111.2 |
250.0 |
270 |
37 |
D
|
| 18000L |
18,000 VA 5 |
1/3 |
133.2 |
472.0 |
510 |
44.4 |
D
|
Notes
| (1) |
Derate power by 10% for operation at 50¡ C ambient
or when using with -UP option.
|
| (2) |
1¿/3¿ systems are factory configured unless
"MODE" option is specified.
|
| (3) |
Repetitive peak current capability
|
| (4) |
Peak in-rush drive capability (non-repetitive,
less than 20 ms)
|
| (5) |
Similar products available to 72,000 VA from
the FCS Series. Contact factory for more information.
|
| (6) |
See Dimensions, weight and environmental Table
below for specifications.
|
Input
| Voltage |
Input range must be specified when ordering
|
| 751L, 1501L, 1503L, 2001L |
103 - 127 VAC, L-N, Single phase or
207 - 251 VAC, L-N, Single phase
|
2750L, 4500L, 6000L, 9000L,
12000L 13500L, 18000L |
187 - 252 VAC, L-L, Three phase
(or 187 - 252 VAC, 1 Phase for 2750L only)
|
| 2750L, 4500L, 9000L, 13500L |
342 - 456 VAC, L-L, Three phase with -UP option
|
| Line Frequency |
47 - 440 Hz
|
| Hold up time |
> 10 msec
|
Standard Measurements, -P and -PT controllers
| Parameter |
Range |
Accuracy* (±) |
Resolution*
|
| AC Measurements
|
| Frequency |
16.00 - 99.99 Hz |
± 0.02 Hz |
0.01 Hz
|
| 100.0 - 500.0 Hz |
± 0.2 Hz |
0.1 Hz
|
| 500.0 - 999.9 Hz |
± 0.5 Hz |
0.1 Hz
|
| 1000 - 5000 Hz |
± 10 Hz |
1 Hz
|
| Phase |
0.0-360.0 |
± 2¡ |
0.1¡
|
| RMS Voltage |
0 -400 V |
1 V |
0.1 V
|
| RMS Current |
0 - 40 A |
0.1 A |
0.01 A
|
| 0 - 400 A |
1 A |
0.1 A
|
| Real Power |
0 - 2 kW |
10 W |
1 W
|
| >0 - 20 kW |
100 W |
10 W
|
| Apparent Power |
0 - 2 kVA |
10 VA |
1 VA
|
| 0 - 20 kVA |
100 VA |
10 VA
|
| Power Factor |
0.000 - 1.000 |
|
0.001
|
System
| Waveforms
|
| Waveform Types |
Sine
Square (optional on -P and -PT)
Clipped Sine, 0 - 20 % THD
User defined (-HGA controller only)
|
| User defined waveform storage -HGA |
18 user defined arbitrary waveforms of 4096
points.
|
| Transient Programming
|
| Transient Types
|
| Voltage: |
drop, step, sag, surge, sweep
|
| Frequency: |
step, sag, surge, sweep
|
| Voltage and Frequency: |
step, sweep
|
| Transient register Parameters: |
Voltage, Frequency, Time, Slew rate, , Phase
angle
|
| Transient storage |
-P and -PT : up to 16 transient registers
-HGA: up to 32 transient steps per list
|
| Time resolution |
1 msec
|
| Time range |
-P and -PT : 1 msec - 9999 sec
-HGA : 1 msec - 300 sec
|
Connectors
| Line input |
Input terminal block
|
| Output |
Output terminal block
|
| Interfaces |
-P and -PT : 24 pin IEEE-488
-HGA : 24 pin IEEE-488 and 9 pin RS232C
|
| Remote sense |
Remote voltage sense terminal block
|
| Miscellaneous |
System interface
Clock and Lock BNC (2) (for rack enclosed system use only)
|
Dimensions, weight, environmental
|
A |
B |
C |
D
|
| Height |
5.25" / 133 mm |
10.5" / 267 mm |
21" / 533 mm |
31.5" 800 mm
|
| Width |
19" / 483 mm |
19" / 483 mm |
19" / 483 mm |
19" / 483 mm
|
| Depth |
23" / 584 mm |
23" / 584 mm |
23" / 584 mm |
23" / 584 mm
|
| Weight (net) |
85 lbs / 39 Kg |
180 lbs / 82 Kg |
360 lbs / 164 Kg |
540 / 250 Kg
|
| Vibration and Shock |
designed to meet NSTA project 1A
transportation levels
|
| Cooling |
Forced air cooling, side air intake,
rear exhaust.
|
| Operating humidity |
0 to 95 % RH, non condensing
|
| Operating Altitude |
0 - 6000 feet
|
| Operating Temperature |
0 to 50 ¡ Celsius
|
| Storage Temperature |
-40 to + 85 ¡ Celsius
|
|
|