| AC Amps * |
Range: 3.00A to 10.00A
Accuracy: ± (1.5% of reading plus 3 counts) Not specified
below 3A
Crest Factor: £3
AC Response: 50 Hz to 500 Hz
|
| DC Amps * |
Range: 0.001A to 10.00A (20A overload for 30 seconds)
Accuracy:± (1.0% of reading plus 3 counts)
|
| AC Volts |
Range: 300 mV to 600.0V rms
Accuracy: ± (1.0% of reading plus 3 counts)
AC Response: 50 Hz to 500 Hz
|
| DC Volts |
Range: 1 mV to 600.0V
Accuracy: ± (0.7% of reading plus 2 counts) |
| Ohms |
Range: 0.1W to 40.00 MW
Best Accuracy: ± (0.9% of reading plus 1 count)
|
| Capacitance |
Range: 1 nF to 9999 µF
Best Accuracy: ± (1.9% of reading plus 2 counts) |
| Continuity |
Beeper guaranteed on < 20W, guaranteed
off > 250W; detects opens or shorts of 250 µs or longer |
| Frequency |
Range: Voltage Input - 5 Hz to 50 kHz
Current Input - 50 Hz to 5 kHz (111 and 112 only)
Accuracy: ± (0.1% of reading plus 2 counts)
|
| Note |
The 110 Series is not recommended
for use with AC current clamps. 170 and 180 series DMMs are recommended
for use with AC clamp accessories. |