Fluke > 123 Industrial ScopeMeter
Fluke 123 Industrial ScopeMeter
Make A Full Sequence of Measurements Without Ever Having To Adjust
The Tool
Scope users know how frustrating triggering can be. The wrong trigger
settings show unexpected, unrecognized, and sometimes wrong results. The
Fluke 123 Industrial ScopeMeter recognizes signal patterns and automatically
sets up correct triggering, to always provide a stable display of even
the most complicated signals - including motor drives and control signals.
Fast Fault Finding with Connect-and-Viewª
"Connect-and-View" hands-off operation provides rock stable, reliable
and repeatable displays of signals without touching a button. All signal
detail is revealed including spikes and noise. Even complex signals are
triggered automatically and flawlessly. The Fluke 123 features unique
"single test lead does all measurements" providing intuitive ease of use.
You can use one and the same set of test leads for waveform display, multiple
meter readings, capacitance and resistance measurements, and continuity
checking. There's no need to swap leads.
Troubleshooting scenario: An automatic wave soldering machine shows
occasional "hiccups". Printed circuit boards don't move along. What's
wrong? Follow this quick sequence of tests to find the problem.
1. Check the line power. The Fluke 123 adjusts automatically. Display
AC volts. Look at the waveform. It shows distortion (harmonics) and noise.
Move the test leads to the power supply. There's no need to readjust the
Fluke 123.
2. Check the DC power to the control unit. The DC voltage level is correct.
The ripple appears okay and no spikes are visible, so the power supply
and filters check out.
3. Move on to the control signal from the digital board. There's no
need to touch a button. The Fluke 123 sets tself up automatically.
You can perform all of these checks while holding the test leads. No
adjustments to the ScopeMeter are necessary. The display is always correct
and stable. Connect-and-Viewª allows for quick and reliable checks of
many test points in a quick sequence with a minimum of errors.
Battery power provides isolation from ground and delivers optimum mobility
with no line cords or ground wire to get in the way of getting good measurements.
The Fluke 123 Industrial ScopeMeter streamlines troubleshooting tasks
making you and your team more efficient.
|
|
| Vertical |
Bandwidth:
20 MHz at inputs
With STL120 1:1 leads: 12.5 MHz
With PM 8918 10:1 probes(optional): 20 MHz
Coupling: AC, DC
Sensitivity: 5 mV/div to 500 V/div
Vertical resolution: 8 bit
Accuracy: ± (2% of reading +0.05 x range/div) |
| Horizontal |
Range: 20 ns/div
to 60 s/div
Acquisition modes: Normal, Single, Roll, Envelope,
Smooth
Max. sample rate:
1.25 GS/s for repetitive signals
25 MS/s for single shot
Record length: 512 samples per channel
Accuracy: ± (0.1% of reading +0.04 x time/div)
Glitch capture: 40 ns or longer |
| Trigger |
Source: A or B.
External via optional ITP120
Modes:
Auto, Triggered, Single
NTSC, PAL, PAL+, SECAM
Pre-trigger: Up to 10 divisions of pre-trigger view
|
| Measurements |
VDC, VAC, VAC+DC, Vpeak, Vpeak-peak,
Frequency, Duty Cycle, Pulse Width and Phase. Measurements can be
scaled to Amps |
| Memory |
2 screens, 10 user setups |
|
|
| DC Voltage VDC |
Ranges: 500 mV,
5V, 50V, 500V, 1250V
Accuracy: ± (0.5% + 5 counts) |
| True RMS Voltage VAC and VAC+DC
|
Ranges: 500 mV,
5V, 50V, 500V, 1250V
Accuracy: ± (1% + 10 counts) |
| Additional Measurements and Functions
|
Ohms, Continuity, Diode Test, Amps,
¼C or ¼F, Capacitance, dBV, dBm, Crest Factor, Touch Hold and ZeroSet.
(Amps, ¼C or ¼F with optional probes)
Graphs meter readings of the MIN and MAX values from 120 seconds to
16 days. |
| TrendPlot |
Automatic vertical scaling and time
compression. Displays the actual and MIN, MAX or AVG reading. |
|
|
| To printer |
supports HP LaserJet®,
DeskJet®, Epson FX/LQ and Postscript |
| To PC |
dump and load settings and data,
compatible with FlukeView® Software SW90W/012E
for Windows |
| Warranty |
3 years parts and labor |
|
|
| Display |
Cold cathode fluorescent backlit
LCD. Contrast and brightness user adjustable. Wide viewing angle.
Size: 72x72 mm (2.8x2.8 inch) |
| Power |
Line voltage adapter/battery
charger included:
Installed battery: Rechargeable NiCd pack
Operating time: Up to 5 hours
Charging time: 4 hours |
| Environmental |
Temperature: 0¼C
to 50¼C
Environmental MIL-T-28800E, Type III, Class 3, Style B:
Electro-Magnetic Compatibility
Emission: EN50081-1(1992): EN55022 and EN60555-2
Immunity: EN50082-2(1992): IEC1000-4-2, -3, -5
Enclosure protection: IP51, IEC529 (dust, drip proof)
|
| Mechanical Data |
Size: 50x115x232
mm (2x4.5x9.1 inches)
Weight: 1.2 kg (2.5 lb.) |
| Safety |
Designed for measurements
on 600V Overvoltage Category III Installations, Pollution Degree 2,
per:
ANSI/ISA S82.01-1994
EN61010.1 (1993) (IEC1010-1)
CAN/CSA-C22.2 No. 1010.1-92
UL3111-1
Surge protection: 6 kV on input A and B
Floating measurements: 600 Vrms from any terminal
to ground |
|  |
|