| AC Amps |
Range: 3 mA to 10.00A (20A overload for 30 seconds)
Accuracy: ± (1.5% of reading plus 3 counts)
Crest Factor: £3
AC Response: 45 Hz to 1 kHz
|
| DC Amps |
Range: 0.01mA to 10.00A (20A overload for 30 seconds)
Accuracy:± (1.0% of reading plus 3 counts)
|
| AC Volts |
Range: 30 mV to 1000V
Accuracy: 45 Hz to 500 Hz 1% of rdg + 3 counts, 500 Hz to
1 kHz 2% of rdg + 3 counts
AC Response: 45 Hz to 1 kHz
|
| DC Volts |
Range: 0.1 mV to 1000V
Accuracy:
175:
± (0.15% of reading plus 2 counts)
177
and 179: ± (0.09% of reading plus 2 counts)
|
| Ohms |
Range: 0.1W to 50.00 MW
Best Accuracy: ± (0.9% of reading plus 1 count)
|
| Capacitance |
Range: 1 nF to 9999 µF
Best Accuracy: ± (1.2% of reading plus 2 counts) |
| Continuity |
Beeper guaranteed on <25W, guaranteed
off >250W; detects opens or shorts of 250 µs or longer |
| Hz |
Range:
Voltage
Input: 2 Hz to 100 kHz
Current
Input: 2 Hz to 30 kHz
Accuracy: ± (0.1% of reading plus 1 count)
|
| Temp (179 Only) |
Range: -40ÅC to +400ÅC, -40ÅF to +752ÅF
Accuracy:1% + 1.0 ÅC, 1% + 1.8 ÅF
|