Home >
Fluke > 190C Series
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Oscilloscope Mode | |
| Vertical Deflection |
Bandwidth:
Rise time:
Bandwidth limiter: User selectable 10 kHz or 20 MHz Number of inputs: 2 plus external trigger. All isolated
from each other and ground. Input coupling: AC, DC with ground level indicator Input sensitivity: 5 mV/div to 100 V/div Input voltage: See general specifications for maximum rating Vertical resolution: 8 bit Accuracy: ±(1.5% of reading + 0.04 x range/div) Input impedance: 1 MW ± 1% // 15 pF ± 2 pF |
| Horizontal |
Maximum real-time sample rate: Number of digitizers: 2 Time base range:
Maximum record length: 1,200 points per input Accuracy: ± (0.01% of reading + 1 pixel) Glitch capture: 50 nsec (5 µsec/div to 1 min/div) Faster
time bases have higher sample rates than |
| Display and acquisition |
Display modes: Input A, input B, dual, average, persistence,
reference, invert, replay Waveform Mathematics: A+B, A-B, A*B all with user selectable scaling of the result ; A versus B (XY-mode) Acquisition modes: Normal, auto, single shot, ScopeRecord™,
roll, glitch capture |
| Trigger and delay |
Source: Input A, input B, external trigger input. All input
references isolated from each other and ground. Modes: Automatic Connect-and-View™, free run, single shot,
edge, delay, video, video line, selectable pulse width Connect-and-View™: Advanced automatic triggering that recognizes
signal patterns, automatically sets up and continuously adjusts
triggering, time base and amplitude. Automatically displays stable
waveforms of complex and dynamic signals like motor drive and control
signals. Video triggering: NTSC, PAL, PAL+, SECAM. Includes field
1 and 2 and line select. Pulse width triggering: Pulse width qualified by time. Allows
for triggering Time delay: 12 divisions pre-trigger view to 1,000 divisions
trigger delay |
| Automatic capture of 100 screens |
The instrument ALWAYS memorizes last 100 screens (no user interaction
or setup required). When an anomaly occurs on screen, there’s 10
seconds to press HOLD and review it. If one sets up the instrument
for triggering on glitches or intermittent anomalies the unit operates
in “baby-sit” mode and will capture 100 events. Replay: Manual or continuous replay. Displays the captured
100 screens as a “live” animation. The contents can also be viewed
by manually scrolling backwards and forwards “screen by screen”. Replay storage: Up to 2 sets of 100 screens can be saved
for later recall and analysis. |
| Automatic scope measurements | VDC, VAC rms, VAC+DC, Vpeak max,
Vpeak min, Vpeak to peak, frequency (Hz), rise time with markers,
fall time with markers positive pulse width, negative pulse width,
positive duty cycle, negative duty cycle, amp AC, amp DC, amp AC+DC,
power factor, watts, VA, VA reactive, phase, temperature °C, temperature
°F, dBV, dBm into 50 W and 600 W |
| Cursor Measurements |
Source: Input A or B Dual horizontal lines: Voltage at cursor 1 and 2, voltage
between cursors Dual vertical lines: Time between cursors, voltage between
markers. Automatic rise time with markers at 10% and 90%, fall time
with markers at 10% and 90% Single vertical line: Min-Max and Average voltage at cursor
position |
| Zoom | Up to 8x horizontal zoom |
| Meter Mode | |
| General | Via 4 mm banana inputs. Fully isolated
from scope inputs and scope ground. The specified accuracy is valid
over the temperature range 18 °C to 28 °C (15 °F to 82 °F). Add 10
% of specified accuracy for each degree °C below 18 °C or above 28
°C (15 °F to 82 °F). |
| Maximum resolution | 5,000 counts |
| Voltmeter ranges | 500 mV, 5 V, 50 V, 500 V, 1,000
V |
| Accuracy |
VDC: ± (0.5 % + 5 counts) 15 Hz to 60 Hz: ± (1 % + 10 counts) 60 Hz to 1 kHz: ± (2.5 % + 15 counts) VAC+DC true rms DC to 60 Hz: ± (1 % + 10 counts) 60 Hz to 1 kHz: ± (2.5 % + 15 counts) |
| Ohms |
Ranges: 500 W, 5 kW, 50 kW, 500 kW, 5 MW, 30 MW Accuracy: ± (0.6 % + 5 counts) |
| Other meter functions |
Continuity: Beeper on < 30 W (± 10 W) Diode test: Up to 2.8 V Amps: Amp DC, Amp AC, Amp AC+DC using an Temperature (°C, °F): With optional accessories. Input impedance: 1 MW ± 1% // 10 pF ± 2 pF Advanced meter functions: Auto/manual ranging, relative
measurements (Zero reference), TrendPlot recording |
| Recorder Mode | |
| ScopeRecord-roll mode |
Dual input waveform storage mode. Source and display: Input A, Input B, Dual Memory depth: 27,000 points per input. Each point consist of Min-Max pair.Min-Max values: Min-Max values are measured at high sample rate ensuring capture and display of glitches Sample Recording Settings:Set Time base range = 5 ms/div to 1 min/div:
Recording modes: Single sweep, continuous roll, start on
external trigger Horizontal scale: Time from start, time of day Zoom: Up to 1000 x zoom Memory: Up to 2 dual input ScopeRecordings can be saved
for later recall and analysis |
| TrendPlot™ Recording |
Dual input electronic paperless chart recorder. Plots, displays
and stores meter and scope measurements. Source and display: Input A, Input B and DMM input Memory depth: 18,000 points record. Per record point a minimum,
maximum and average value, and a time and date stamp are stored. Ranges: 5 s/div to 30 min/div in normal view mode. 5 min/div
to 48 hour/div in view-all mode (overview of total record) Recorded timespan: Up to 22 days with a resolution of 100
sec. Recording mode: Continuous roll Measurement speed: 5 measurements per second maximum Zoom: Up to 64 x zoom Memory: Up to 2 TrendPlot recordings can be saved for later
recall and analysis |
| Cursor measurements - All Recorder Modes |
Source: Input A, B or DMM input Dual vertical lines: Min-Max or Average voltage. Time between
cursors. Single vertical line: Min-Max or Average voltage. Absolute
date and time or time from start. |
| General Specifications | |
| Case |
Design: Rugged, shock proof with integrated Drip and dust proof: IP51 according to IEC529 Shock and vibration: Shock 30 g, Vibration 3 g |
| Display |
Bright LCD with CCFL backlight, 50/80 Cd/m2 without/with power
adapter. Size: 115 x 86 mm (4.5 x 3.4 inches) Resolution: 320 x 240 pixels Contrast and brightness: User adjustable, |
| Memory Save and Recall |
Scope memories: 10 memory locations that each can contain
two waveforms plus corresponding setup. Plus 5 extra memory locations
after web refistration. Recorder memories: 2 memory locations that each can contain 100 captured dual input scope screens, or a dual input ScopeRecord (27,900 Min-Max pairs per input), or a dual reading Trendplot (18,000 Min-Max pairs and avg. |
| Real-time Clock |
Time and date stamp for ScopeRecord, 100 captured screens and Trendplots. |
| Power |
Line power: Country specific line voltage adapter/battery
charger included Battery power: Rechargeable NiMH (installed) Battery operating time: 4 hours Battery charging time: 4 hours Battery power saving functions: Auto power down with adjustable
power down time. On screen battery power indicator |
| Mechanical data |
Size: 256 x 169 x 64 mm (10.1 x 6.6 x 2.5 inches) Weight: 1.95 kg (4.3 lbs) |
| Safety | Compliance: EN61010-1 (1993)
Pollution degree 2, UL 3111-1 (1994), CAN/CSA C22.2 No.1010.1 (1992), ANSI/ISA S82.01 (1994) |
| Input voltage ratings |
Maximum probe voltage: 1,000 V CAT II, 600 V CAT III Floating voltage: 1,000 V CAT II, 600 V CAT III Independently isolated: 1,000 V CAT II, 600 V CAT III Maximum voltage on BNC input directly Maximum voltage on meter input: 1,000 V CAT II, 600 V CAT
III |
| Environmental |
Operating temperature: 0 °C to +50 °C Storage temperature: -20 °C to +60 °C Humidity Maximum operating altitude: 3,000 m (10,000 feet) Maximum storage altitude: 12 km (40,000 feet) Electro-Magnetic Compatibility: EN 61326-1 for emission
and immunity |
| Optically isolated PC/Printer interface |
To printer: Supports HP Laserjet®,Deskjet®,Epson FX/LQ® and postscript printers via optional PAC 91 To PC: Transfer instrument settings, screen images and waveform data, compatible with FlukeView®software for Windows® via optional PM9080. |
| Warranty | 3 years |
|
|||||
|
|||||