Fluke 2640A NetDAQ Data Acquisition Unit
NetDAQ Data Acquisition Units give you a powerful combination
of hardware and software that's ideal for small-to-medium scale process
monitoring and test systems. They answer the escalating need for measurement,
recording, and analysis tools that enable you to improve quality, maximize
process efficiency and meet regulatory requirements. Building blocks of
20 channels can be expanded into integrated systems of up to 400 channels.
Choose between two models for speed up to 1000 rps and accuracy up to
0.01%. All NetDAQs utilize Fluke's patented Universal Input Module which
accepts any combination of analog input types for each of its 20 channels
- without the need for external signal conditioning. Simply pre-wire the
Universal Input Module to directly measure temperature, dc volts, ac volts,
resistance, 4-20 mA, and frequency. (For more information refer to the
Universal Input Module in this section.)
Distributed NetDAQ systems plug right into your existing
networks to send data directly to a PC. This saves the cost of setting
a new network and allows multiple users to simultaneously view data in
real time. A NetDAQ unit can also be used as a portable dedicated system
connected to a notebook computer for maintenance, product validation,
research, and troubleshooting applications.
Features at a Glance:
- Data Acquisition, Up to 1,000 Readings Per Second
- 20 Analog Input Channels Expandable Up to 400 Channels
- Extensive Optional Plotting and Trending Capabilities
- Optional Wall, Cabinet, or Rack Mounting
- May Be Connected to Ethernet Networks
- Replaces Chart Recorders
Specifications
|
2640 NetDAQ
|
|
DC Volts
|
Range: 90 mV to 150/300V
Resolution: 0.3 µV to 1 mV
Accuracy (3-Sigma): 0.01 %*
|
|
AC Volts
|
Range: 300 mV to 30V
Resolution: 10 µV to 10 mV
Accuracy (3-Sigma): 0.3%*
|
|
Resistance
|
Range: 300W to 3MW
Resolution: 1mW to 10W
Accuracy (3-Sigma): 0.015 %*
|
|
Frequency
|
Range: 15 Hz to 1MHz
Resolution: 0.01 Hz to 100 Hz
Accuracy (3-Sigma): 0.05 % *
|
|
RTD (Pt 100)
|
Range: -200 to 600¼C
Resolution: 0.003¼C
Accuracy: 0.06¼C *
|
|
J Type Thermocouple
|
Range: -100 to 760¼C
Resolution: 0.02¼C**
Accuracy (3-Sigma): 0.35¼C *
|
|
K type Thermocouple
|
Range: -100 to 1372¼C
Resolution: 0.02¼C**
Accuracy (3-Sigma): 0.4¼C*
|
|
T Type Termocouple
|
Range: -100 to 400¼C
Resolution: 0.02¼C**
Accuracy: 0.3¼C *
|
|
Other Thermocouple Types
|
R, S, B, C, E, N
|
Total instrument accuracy for 90 days following calibration and ambient
temperature range of 18 to 28 Degrees C. Includes A/D errors, linearization
conformity, initial calibration error, isothermality errors, reference
junction conformity and power line voltage effects within the range
from 107V ac to 264V ac.
**Resolution is 0.02¡C or 0.04¡F over the useful range of
base metal thermocouples (J, K, T, E, N) and 1¡C or 2¡F resolution for
types R, S, B, and C with slow scan.
|
2645 NetDAQ
|
|
DC Volts
|
Range: 90 mV to 50V
Resolution: 3 µV to 10 mV
Accuracy: 0.01 %*
|
|
AC Volts
|
Range: 30V to 50mV
Resolution: 10 µV to 1 mV
Accuracy: 0.3%*
|
|
Resistance
|
Range: 300W to 3MW
Resolution: 10mW to 100W
Accuracy: 0.02 %*
|
|
Frequency
|
Range: 15 Hz to 1MHz
Resolution: 0.01 Hz to 100 Hz
Accuracy: 0.05%*
|
|
RTD (Pt 100)
|
Range: -200 to 600¼C
Resolution: 0.03¼C
Accuracy: 0.16¼C*
|
|
J Type Thermocouple
|
Range: -100 to 760¼C
Resolution: 0.2¼C**
Accuracy: 0.7¼C*
|
|
K Type Thermocouple
|
Range: -100 to 1372¼C
Resolution: 0.2¼C**
Accuracy: 0.8¼C*
|
|
T Type Thermocouple
|
Range: -100 to 400¼C
Resolution: 0.2¼C**
Accuracy: 0.7¼C*
|
|
Other Thermocouple types
|
R, S, B, C, E, N
|
*Total instrument accuracy for 90 days following
calibration and ambient temperature range of 18 to 28 Degrees C. Includes
A/D errors, linearization conformity, initial calibration error, isothermality
errors, reference junction conformity and power line voltage effects
within the range from 107V ac to 264V ac.
**Resolution is 0.2¡C or 0.4¡F over the useful range of base
metal thermocouples (J, K, T, E, N) and 1¡C or 2¡F resolution for types
R, S, B, and C with slow scan.
|
General Specifications
|
|
Channel Capacity
|
Analog inputs: 20
Computed channels: 10
Digital I/O & Alarm Outputs: 8 total
Totalizer: 1
|
|
Computed Channels
|
10 computed channels can be created by processing
analog input channels and other computed channels with the following
methods: Addition, subtraction, multiplication, division, log,
natural log, exponent, square root, absolute value, integer function,
average (average of a group of channels), difference (difference
between any two channels), difference (between a channel and a
group of averaged channels)
|
|
Scan Speed
|
2640A: Slow: 6 channels/second nominal; Medium:
41 (50 Hz), 48 (60 Hz) channels/second nominal; Fast: 100 channels/second
nominal
2645A: Slow: 45 (50 Hz), 54 (60 Hz) channels/second nominal; Medium:
200 channels/second nominal; Fast: 1000 channels/second nominal
|
|
Analog to Digital Converter
|
2640A: Multi-slope type, linear to 18 bits.
2645A: Multi-slope type, linear to 16 bits
|
|
Common Mode Rejection (slow rate)
|
2640A: AC: >=120 dB (50/60 Hz, +/-0.1% max 1 kW
source imbalance); DC: >=120 dB.
2645A: AC: >=100 dB (50/60 Hz, +/-0.1% max 1 kW source imbalance);
DC: >=100 dB.
|
|
Normal Mode Rejection (slow rate)
|
50 dB @ 50/60 Hz, +/-0.1%
|
|
Common Mode and Normal Mode Voltage Maximum
|
2640A: 300 V dc or V ac rms (channels 1,11); 150
V dc or V ac rms (all other channels).
2645A: 50 V dc or 30 V ac rms (all channels)
|
|
Power
|
107 to 264 V ac, 50 or 60 Hz (<15W), or 9 to 16
V dc (<6W)
|
|
Temperature, Humidity (non-condensing)
|
-20¼C to 60¼C. Storage: -40¼C to 75¼C, 5% to 95%
RH
|
|
Electromagnetic Interference (EMI)
|
Passes FCC EMI Class B Equipment, Vfg. 243, European
Norms EN50081-1 and EN50082-1, (CE.)
|
|
Weight
|
3.7 kg (8.2 lbs.)
|
|
|