Fluke 2645A NetDAQ Data Acquisition Unit

NetDAQ Data Acquisition Units give you a powerful combination of hardware and software that's ideal for small-to-medium scale process monitoring and test systems. They answer the escalating need for measurement, recording, and analysis tools that enable you to improve quality, maximize process efficiency and meet regulatory requirements. Building blocks of 20 channels can be expanded into integrated systems of up to 400 channels. Choose between two models for speed up to 1000 rps and accuracy up to 0.01%. All NetDAQs utilize Fluke's patented Universal Input Module which accepts any combination of analog input types for each of its 20 channels - without the need for external signal conditioning. Simply pre-wire the Universal Input Module to directly measure temperature, dc volts, ac volts, resistance, 4-20 mA, and frequency. (For more information refer to the Universal Input Module in this section.)

Distributed NetDAQ systems plug right into your existing networks to send data directly to a PC. This saves the cost of setting a new network and allows multiple users to simultaneously view data in real time. A NetDAQ unit can also be used as a portable dedicated system connected to a notebook computer for maintenance, product validation, research, and troubleshooting applications.

Features at a Glance:

  • Data Acquisition, Up to 1,000 Readings Per Second
  • 20 Analog Input Channels Expandable Up to 400 Channels
  • Extensive Optional Plotting and Trending Capabilities
  • Optional Wall, Cabinet, or Rack Mounting
  • May Be Connected to Ethernet Networks
  • Replaces Chart Recorders
Specifications

2640 NetDAQ

DC Volts

Range: 90 mV to 150/300V
Resolution: 0.3 µV to 1 mV
Accuracy (3-Sigma): 0.01 %*

AC Volts

Range: 300 mV to 30V
Resolution: 10 µV to 10 mV
Accuracy (3-Sigma): 0.3%*

Resistance

Range: 300W to 3MW
Resolution: 1mW to 10W
Accuracy (3-Sigma): 0.015 %*

Frequency

Range: 15 Hz to 1MHz
Resolution: 0.01 Hz to 100 Hz
Accuracy (3-Sigma): 0.05 % *

RTD (Pt 100)

Range: -200 to 600¼C
Resolution: 0.003¼C
Accuracy: 0.06¼C *

J Type Thermocouple

Range: -100 to 760¼C
Resolution: 0.02¼C**
Accuracy (3-Sigma): 0.35¼C *

K type Thermocouple

Range: -100 to 1372¼C
Resolution: 0.02¼C**
Accuracy (3-Sigma): 0.4¼C*

T Type Termocouple

Range: -100 to 400¼C
Resolution: 0.02¼C**
Accuracy: 0.3¼C *

Other Thermocouple Types

R, S, B, C, E, N

Total instrument accuracy for 90 days following calibration and ambient temperature range of 18 to 28 Degrees C. Includes A/D errors, linearization conformity, initial calibration error, isothermality errors, reference junction conformity and power line voltage effects within the range from 107V ac to 264V ac.
**Resolution is 0.02¡C or 0.04¡F over the useful range of base metal thermocouples (J, K, T, E, N) and 1¡C or 2¡F resolution for types R, S, B, and C with slow scan.

2645 NetDAQ

DC Volts

Range: 90 mV to 50V
Resolution: 3 µV to 10 mV
Accuracy: 0.01 %*

AC Volts

Range: 30V to 50mV
Resolution: 10 µV to 1 mV
Accuracy: 0.3%*

Resistance

Range: 300W to 3MW
Resolution: 10mW to 100W
Accuracy: 0.02 %*

Frequency

Range: 15 Hz to 1MHz
Resolution: 0.01 Hz to 100 Hz
Accuracy: 0.05%*

RTD (Pt 100)

Range: -200 to 600¼C
Resolution: 0.03¼C
Accuracy: 0.16¼C*

J Type Thermocouple

Range: -100 to 760¼C
Resolution: 0.2¼C**
Accuracy: 0.7¼C*

K Type Thermocouple

Range: -100 to 1372¼C
Resolution: 0.2¼C**
Accuracy: 0.8¼C*

T Type Thermocouple

Range: -100 to 400¼C
Resolution: 0.2¼C**
Accuracy: 0.7¼C*

Other Thermocouple types

R, S, B, C, E, N

*Total instrument accuracy for 90 days following calibration and ambient temperature range of 18 to 28 Degrees C. Includes A/D errors, linearization conformity, initial calibration error, isothermality errors, reference junction conformity and power line voltage effects within the range from 107V ac to 264V ac.
**Resolution is 0.2¡C or 0.4¡F over the useful range of base metal thermocouples (J, K, T, E, N) and 1¡C or 2¡F resolution for types R, S, B, and C with slow scan.

General Specifications

Channel Capacity

Analog inputs: 20
Computed channels: 10
Digital I/O & Alarm Outputs: 8 total
Totalizer: 1

Computed Channels

10 computed channels can be created by processing analog input channels and other computed channels with the following methods: Addition, subtraction, multiplication, division, log, natural log, exponent, square root, absolute value, integer function, average (average of a group of channels), difference (difference between any two channels), difference (between a channel and a group of averaged channels)

Scan Speed

2640A: Slow: 6 channels/second nominal; Medium: 41 (50 Hz), 48 (60 Hz) channels/second nominal; Fast: 100 channels/second nominal
2645A: Slow: 45 (50 Hz), 54 (60 Hz) channels/second nominal; Medium: 200 channels/second nominal; Fast: 1000 channels/second nominal

Analog to Digital Converter

2640A: Multi-slope type, linear to 18 bits.
2645A: Multi-slope type, linear to 16 bits

Common Mode Rejection (slow rate)

2640A: AC: >=120 dB (50/60 Hz, +/-0.1% max 1 kW source imbalance); DC: >=120 dB.
2645A: AC: >=100 dB (50/60 Hz, +/-0.1% max 1 kW source imbalance); DC: >=100 dB.

Normal Mode Rejection (slow rate)

50 dB @ 50/60 Hz, +/-0.1%

Common Mode and Normal Mode Voltage Maximum

2640A: 300 V dc or V ac rms (channels 1,11); 150 V dc or V ac rms (all other channels).
2645A: 50 V dc or 30 V ac rms (all channels)

Power

107 to 264 V ac, 50 or 60 Hz (<15W), or 9 to 16 V dc (<6W)

Temperature, Humidity (non-condensing)

-20¼C to 60¼C. Storage: -40¼C to 75¼C, 5% to 95% RH

Electromagnetic Interference (EMI)

Passes FCC EMI Class B Equipment, Vfg. 243, European Norms EN50081-1 and EN50082-1, (CE.)

Weight

3.7 kg (8.2 lbs.)



 


 
 