Fluke 54-2 Dual Input Thermometer
Features
- Large backlit dual display shows any combination of T1, T2 (52 and
54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG
- Relative time clock on MIN, MAX, and AVG provides a time reference
for major events
- Electronic Offset function allows compensation of thermocouple errors
to maximize overall accuracy
- Measures J, K, T, and E-types of thermocouples
- Readout in ¼C, ¼F, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the
calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any
metal object (with the rare earth magnet) or secure around a pipe (with
hook-and-loop straps) for hands-free operation.
- Data Logging up to 500 points of data with user adjustable recording
interval
- Additional thermocouple types R, S, and N (for a total of 7 different
types)
- Real time clock captures the exact time of day when events occur
- Recall function allows logged data to be easily reviewed on the meter
display
- IR communication port allows data to be exported to optional FlukeViewª
Temperature PC software for further analysis and graphing
Specifications
| Measurement accuracy |
Above -100 ¡C (-148 ¡F):
J, K, T, E, and N-type: ±[0.05% + 0.3¡C (0.5¡F)]*
R and S-type: ±[0.05% + 0.4¡C (0.7¡F)]*
Below -100 ¡C (-148 ¡F):
J, K, E, and N-types: ±[0.20% + 0.3¡C (0.5¡F)]*
T-type: ±[0.50% + 0.3¡C (0.5¡F)] |
| Display resolution |
0.1¡C / ¡F / K < 1000¡
1¡C / ¡F / K þ 1000¡ |
| Measurement range |
J-type: -210¡C to 1200¡C (-346¡F
to 2192¡F)
K-type: -200¡C to 1372¡C (-328¡F to 2501¡F)
T-type: -250¡C to 400¡C (-418¡F to 752¡F)
E-type: -150¡C to 1000¡C (-238¡F to 1832¡F)
N-type: -200¡C to 1300¡C (-328¡F to 2372¡F)*
R and S-type: 0¡C to 1767¡C (32¡F to 3212¡F)* |
| Temperature scale |
ITS-90 |
| Applicable standards |
NIST-175 |
| Environmental |
Operating temperature:
-10¡C to 50¡C (14¡F to 122¡F)
Storage temperature:
-40¡C to 60¡C (-40¡F to 140¡F)
Humidity:
0% to 90%; 0¡C to 35¡C (32¡F to 95¡F)
0% to 70%; 0¡C to 50¡C (32¡F to 122¡F) |
| General |
Unit weight: 400g (14 oz)
Dimensions: 17.3 cm L x 8.6 cm W x 3.8 cm D (6.8 in L x 3.4 in W x
1.5 in D)
Battery: 3 AA batteries; typical 1000-hour life
Certification: CE, CSA, T†V (pending)
Safety: CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 |
|
|
|