Home >
Fluke Networks > 990
Fluke Networks 990DSL CopperPro Loop Tester
- Replaces up to twelve traditional test sets
- Troubleshoots and qualifies lines for POTS, ADSL and other special
services
- Time Domain Reflectometer (TDR) feature allows precision fault location
- Fast, accurate and easy to use
- Compact, rugged and weather resistant
Product Capabilities
CopperPro is a handheld, multifunction OSP test set.
In its basic configuration, CopperPro offers a broad range of Plain Old
Telephone Services (POTS) troubleshooting, fault location and line qualification
capabilities. Its Wideband/TDR option adds high frequency transmission
testing and qualification functions for services like ADSL, HDSL and HDSL2,
ISDN, T1, E1 and DDS. And the TDR feature of the option adds precise fault
location and analysis. The Wideband/TDR option can be added at time of
purchase or later at an authorized service center.
General Specifications
|
| Physical |
Size: 9.8"H x 5.3"W x 3.2"D (24.9cm x 13.5cm x 8.1cm)
Weight: 4 lbs (1.81 kg)
Display: 320 x 240 pixel graphic LCD with backlight and adjustable
contrast
LED Indicator: Charging status indicator (side connector panel)
Communication Port: RS-232 PC/Printer port (DB-9)
|
| Power |
AC Operation: External AC adapter/charger
Battery Type (installed): Internal removable NiMH rechargeable
battery pack
Battery Life: A fully charged battery provides approximately 16
hours of normal use
Battery Recharge Time (in tester): 2 to 3 hours for a fully discharged
battery pack
|
| Environmental |
Operating Temperature: -4Á to 140Á F (-20Á to 60Á C)
Storage Temperature: -40Á to 158Á F (-40Á to 70Á C)
Humidity Tolerance (operation without condensation): 95%
Rain Resistance: IEC60529 IP02, International protection water
dripping
Vibration: Random, 2 g, 5 Hz to 500 Hz
Shock: 1 Meter Drop Test
Altitude: 4500 m (15,000 ft)
|
| Regulator Compliance |
Safety: CSA C22.2 No.1010.1
CE: EN 61326 Emissions and Immunity CLASS A; EN 61010-1 + 2nd ammendment
|
Basic CopperPro
|
| AC Voltage |
0 to 250V (1% ± 0.5V accuracy)
|
| DC Voltage (RIN=100 kohms or 10 Mohms) |
Range: 0 to 150V (1% ± 0.5V accuracy); 150 to 300V (2% accuracy)
|
| DC Loop Current (430 ohms) |
0 to 100 mA (2% ± 0.3 mA accuracy)
|
Resistance
(shorts & grounds) |
0 to 100 ohms (0.1% ± 0.10 ohm accuracy)
100 ohms to 1000 kohms (0.2% ± 0.10 ohm accuracy)
4 kohms to 100 Mohms (3% accuracy)
|
| Leakage Stress |
2 kohms to 100 Mohms (3% accuracy)
|
| Opens |
0 to 3000 ft (1% ± 5 ft accuracy)
3 to 50 kft (3% accuracy)
50 to 80 kft (5% accuracy)
|
| Splits |
Range: 0 to 50 kft (Accuracy: 10% of Cable Length)
|
| RFL (RTS = Res. to Strap) |
Fault Resistance (Rf): 0 to 30 Mohms
Loop Resistance: 0 to 4000 ohms
Resistance to Fault (@ Rf = 100 kohms): 0 to 100 ohms (0.1% RTS
± 0.10 ohm); 100 ohms to 4 kohm (0.3% RTS ± 0.10 ohm)
|
| Load Coils |
0 to 6 (± 1 accuracy)
|
| Tracing Tone |
Frequency: 577.5 Hz (0.1% accuracy)
Range: 10 Vp-p > 3.5 (10% accuracy)
|
| VF Noise |
Impedance: 600 ohms, Bridged (1% accuracy)
Filters: C, CN, 3k, 15k, Psophometric
Metallic Noise: 0 to 10 dBrn (± 2 dB accuracy); 10 to 100 dBrn
(± 1 dB accuracy)
Power Influence: 40 to 120 dBrn (± 2 dB accuracy)
|
| VF Loss |
Signal Level: -40 to 10 dBm (± 0.5 dBm accuracy)
Frequency: 100 Hz to 20 kHz (0.1% ± 2 Hz accuracy)
|
| VF Longitudinal Balance (0 to 70 dB ± 2 dB) |
Disturbing Frequency: 200 to 2500 Hz (0.1% accuracy)
Impedance: 600 ohms (1% accuracy)
Filters: C, Psophometric
|
| Send VF Tone |
Frequency: 100 Hz to 20 kHz (0.1% accuracy)
Amplitude (settable) Range: -20 to 3 dBm
Amplitude Accuracy: ± 0.5 dB (1 dB increments)
Impedance: 600 ohms, 900 ohms (1% accuracy)
|
CopperPro Wideband Option
|
| WB Noise/Level |
Impedance Range: 100 ohms, 135 ohms, Bridged (1% accuracy)
Filters: E, F, G, None
Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)
Amplitude: -50 to 3 dBm (± 1 dB @ 135 ohms); -90 to -50 dBm (±
3 dB @ 135 ohms)
|
| WB Loss |
Impedance: 135 ohms (1% accuracy)
Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)
Magnitude: 0 to 50 dB (± 1 dB accuracy); 50 to 70 dB (± 2 dB accuracy)
|
| WB Longitudinal Balance (0 to 70 dB; ± 2 dB) |
Disturbing Frequency: 10 to 1200 kHz (0.1% accuracy)
Impedance: 100 ohms, 135 ohms (1% accuracy)
Filters: E, F, G, None
|
| Send WB Tone |
Frequency: 10 kHz to 1200 kHz (0.1% ± 508 Hz accuracy)
Amplitude (fixed): 0.0 dBm (± 0.5 dB accuracy)
Impedance: 100 ohms, 135 ohms (1% accuracy)
|
| WB Impulse Noise |
Impedance Range: 100 ohms, 135 ohms, Bridged (1% accuracy)
Filters: E, F, G, None
Test Time: 1 to 1440 Minutes (1% accuracy)
Impulse Counter: 0 to 9999
Counter Threshold: -40 to 0 dBm (± 1 dB accuracy)
|
| ADSL Auto-Test |
Impedance: 100 ohms
Noise Filters: E, F, G, None
ADSL Standard: ANSI, Full, G, Lite
|
| Data Rate Prediction |
Resolution: 32 kb/s
Downstream Rate Range: 0 to 8192 kb/s
Downstream Rate Accuracy: ± 96 kb/s (3 units of resolution)
Upstream Rate Range: 0 to 1024 kb/s
Upstream Rate Accuracy: ± 64 kb/s (2 units of resolution)
|
CopperPro TDR Option
|
| Impedance |
135 ohms (1% accuracy)
|
| Pulse-width |
20, 100, 500, 1000, 2500, 5000 ns (10% ± 5 ns accuracy)
|
| Vop Selection |
0.300 to 0.999
|
| Range (Vop=0.64) |
30,000 ft (9144m)
|
| Range Selection (Auto.) |
10 ft to 48 kft (3 to 14630m)
|
| Horizontal Resolution |
0.5 to 156 ft (0.1524 to 47.5m)
|
| Distance to Reflect. |
Range: 0 to 30,000 ft (0 to 9144m)
Accuracy: 1% ± Vop Uncertainty
|
| Vertical Gain |
Range: 80 dB
Accuracy: 2 dB
|
| Power Filter |
5 kHz Highpass
|
| Averaging Filter |
4x Waveform Avg.
|
| Input Protection |
± 400 V pk
|
|  |
|