Compact
and Portable
At 6.6 lbs (3 kg), this compact scope is easy
to carry and fits very easily onto crowded workbenches.
High-Speed
Sampling Rate and Long Memory
Operates at 500 MS/s sampling rate with 100 MHz analog
bandwidth. Each channel has a long 100 kpoints acquisition
memory.
High
Accuracy
Vertical accuracy is within 2% and horizontal accuracy
is 50 ppm (0.005%).
Cursor
Measurements
Two cursors (two vertical or two horizontal) let you
measure voltage difference (delta V), time difference
(delta t), frequency (1/delta t), and V at t for a
specific waveform.
Auto
Copy
Display or waveform data can be output automatically
to a specified device (built-in printer, ATA card,
or floppy disk).
Simple
to Use, yet Powerful
Features a variety of automatic measurements,
triggers, floppy, internal printer, and interfaces
to external devices.
Easy-to-Use
Menu Selection
Just turn the function knob to select a menu item,
then press to activate it.
Help
Menu
Explains the various menu functions. Useful for beginners
or for advanced users needing to know what a particular
function does.
Event
Trigger
Wide range of triggers, including event triggers (count/burst/extra/missing)
and TV triggers (NTSC/PAL/SECAM).
Hardware
Five-Digit Frequency Counter
Input signal frequency can be shown in five digits.
No more guessing about signal aliasing.
13
Automatic Measurements
All the basic automatic functions required for common
measurements are provided, assuring quick, accurate
results and improving working efficiency.
25
GS/s Equivalent Sampling
Using the equivalent sampling method, the time resolution
is increased up to 40 ps (equivalent to 25 GS/s).
Pre-trigger information is available.
|
|
Acquisition
System (Common to CH1, CH2)
Sensitivity:
2 mV/div 10 V/div (1-2-5 steps) (0.8 mV/div zoomed)
Bandwidth:
DC 100 MHz (frequency cutoff is 10 Hz for AC coupling)
Max single-shot sampling rate: 500 MS/s
Equivalent sampling mode: 25 GS/s
Peak detect: 500 MS/s
Resolution: 8-bit
Acquistion Memory: Short 5 kpts/ch; long 100 kpts/ch
Storage Modes: Normal, equivalent sampling, peak detect,
average, roll
Triggering
System
Modes: Auto, Normal Single
Sources: CH1, CH2, EXT
Types: Edge, Event, TV
Event trigger: Count, Burst, Missing, Extra
Timebase
System
Time/div range: 5 ns 50 s/div (1-2-5 steps)
Roll Mode: 500 MS 1000 s/div
Display
Functions
Display: 5.7" (145 mm) backlit LCD display
X-Y display: X = CH1, Y = CH2
Help function: Available on screen in reverse video
Waveform
Storage
Save and Recall
Media: ATA card, floppy disk (3.5")
Data type: Setup, waveform
Record format: Binary and ASCII formats are available
for waveform data.
Comment: Text comments can be appended to waveform files.
Auto copy: Waveforms can be automatically copied to
a storage device after each trigger.
Math
and Measurement Functions
Cursors: delta V, delta t, 1/delta t, V at t
Parameters: Tr, Tf, Vrms, Vmean, etc. (total 13 items)
Arithmetic functions: +, -, x
Frequency counter: Five display digits, 1 Hz 100 MHz
frequency range
Other
Features
Auto setup: Automatically setup V, H range and trigger
for repetitive signal
Interface: RS-232C
Data output: Centronics
Built-in printer: Line thermal printer, roll print available
Floppy, ATA card: Output format TIFF, BMP
Centronics formats: DPU-414, ESC-P09, ESC-P24, PC-PR201,
TIFF, BMP
Power
Supply
Voltage range: AC 100 240 V
Power consumption: 90 VA max (with built-in printer
operation)
Dimensions
and Weight
Dimensions (width, height, length): 8.4"
x 6.7" x 6.5" (214 mm x 170 mm x 166 mm)
Weight: Approx. 6.6 lbs (3.0 kg) excluding accessories
|