The GN 6025/S50 ORL meter is a handheld Loss Test Set
for measuring power, attenuation and Optical Return Loss (ORL).
The GN 6025/S50 ORL Loss Test Sets are fast and easy-to-use handheld
instruments designed for attenuation, power throughput and Optical Return
Loss (ORL) measurements on point-to-point fiber optic links. They feature
a rugged design, built to withstand the difficult testing environments
of fiber optic cable installation and maintenance. Calibrated at five
wavelengths (850, 1300, 1310, 1550, and 1625 nm), these instruments are
ideal for testing in all singlemode and multimode fiber applications.
Test time is dramatically reduced and documentation errors eliminated
when units are operating in the auto-wavelength switching mode. The auto
wavelength switching mode synchronizes the light source with a GN-6025
series Power Meter or Loss Test Set and automatically switching between
two wavelengths. The user is able to store two loss readings and increment
to the next fiber with only one button push for the easiest and fastest
results available.
Benefits
- ORL capability provides for advanced fiber reflectance characterization
- Combined light source and power meter permit loop-back and dual fiber
testing
- Rugged design ensures years of use in the most challenging environments
- Multi-wavelength calibrations provide for L-band characterization
- LP View Windows¨-based PC software enables efficient documentation
and accurate reporting
Specifications
Model
|
GN-6025/S50 ORL Loss Test Set
|
| Calibrated Wavelengths |
850, 1300, 1310, 1550, 1625 nm |
| Range |
+3 to -66 dBm |
| Accuracy1,2 |
±0.2 dBm |
| Center Wavelength |
1310 nm ±20 nm
1550 nm ±20 nm |
| Output Power |
-8 dBm (SMF 28) |
| Linearity1 |
±0.1 dB @ 0 to -65 dBm |
| Resolution |
0.01 dB/0.1 dB selectable |
| ORL Accuracy |
± 0.5 dB @ 0-50 dB
± 1.0 dB @ 50-60 dB |
| ORL Stability |
± 0.2 dB @ 0-50 dB
± 0.5 dB @ 50-60 dB |
1 Typical specs at 23ˇ C
2 Typical 1310 nm specs at 23ˇ C with -20 dBm power input