Home >
NetTest > Loss Test Kits
NetTest GN-6025 Loss Test Kits
Loss Test Kits are handheld tools packaged together in a convenient transit
case designed for specific fiber optic applications.
NetTest offers a variety of Loss Test Kits to perform attenuation and
power throughput measurements for point-to-point fiber optic links. The
Loss Test Kits are designed for optimized testing in a variety of applications
ranging from multimode LAN to long-haul single-mode networks. Further
diversity enhances the ability to make measurements in one direction or
bi-directional network applications, fiber microscopes for connector inspection
and fiber optic cleaning.
Kits feature fast and easy-to-use handheld Power Meters, Light Sources
or Loss Test Sets. They provide a rugged design, built to withstand the
difficult testing environments of fiber optic cable installation.
Benefits
- Rugged and easy to use
- Packaged to operate in specific fiber applications
- Accurate attenuation measurements in minimum time
Specifications
| |
GN-6025/M50
|
GN-6025/A50
|
GN-6025C/A50
|
GN-6025/A60
|
GN-6025C/A60
|
| Calibrated Wavelengths |
850, 1300, 1310, 1550, 1625 nm |
850, 1300, 1310, 1550, 1625 nm |
850, 1300, 1310, 1550, 1625 nm |
850, 1300, 1310, 1550, 1625 nm |
850, 1300, 1310, 1550, 1625 nm |
| Range |
+3 to -66 dBm |
+3 to -66 dBm |
+20 to -56 dBm |
+3 to -66 dBm |
+20 to -56 dBm |
| Accuracy1,2 |
±0.2 dBm |
±0.2 dBm |
±0.2 dBm |
±0.2 dBm |
±0.2 dBm |
| Linearity1 |
±0.1 dB @ 0 to -65 dBm |
±0.1 dB @ 0 to -65 dBm |
±0.1 dB @ 0 to -50 dBm |
±0.1 dB @ 0 to -65 dBm |
±0.1 dB @ 0 to -50 dBm |
| Resolution |
0.01 dB/0.1 dBselectable |
0.01 dB/0.1 dBselectable |
0.01 dB/0.1 dBselectable |
0.01 dB/0.1 dBselectable |
0.01 dB/0.1 dBselectable |
| Center Wavelength |
850/1300 nm ± 20 nm |
1310/1550 nm ± 30 nm |
1310/1550 nm ± 30 nm |
1550/1625 nm ± 30 nm |
1550/1625 nm ± 30 nm |
| Stability (8 hours)2 |
±0.05 dB |
±0.05 dB |
±0.05 dB |
±0.05 dB |
±0.05 dB |
1 Typical specs at 23¡ C
2 Typical 1310 nm specs at 23¡ C with -20 dBm power input |
Model
|
GN-6025/S50 ORL Loss Test Set
|
| Calibrated Wavelengths |
850, 1300, 1310, 1550, 1625 nm |
| Range |
3 to -66 dBm |
| Accuracy1,2 |
±0.2 dBm |
| Center Wavelength |
1310 nm ±20 nm
1550 nm ±20 nm |
| Output Power |
-8 dBm (SMF 28) |
| Linearity1 |
±0.1 dB @ 0 to -65 dBm |
| Resolution |
0.01 dB/0.1 dB selectable |
| ORL Accuracy |
± 0.5 dB @ 0-50 dB
± 1.0 dB @ 50-60 dB |
| ORL Stability |
± 0.2 dB @ 0-50 dB
± 0.5 dB @ 50-60 dB |
1 Typical specs at 23¡ C
2 Typical 1310 nm specs at 23¡ C with -20 dBm power input
3 With 10 minute warm-up |
|  |
|