Rohde & Schwarz NRVS Power MeterCharacteristicsMeasurement Functions - Average power,
pulse power, peak envelope power. Frequency and Level Range - DC to 40 GHz, 100 pW to 30 W. Probes and Sensors - All NRV sensors and URV5 probes. Display - LCD for digits, units, menu-guided operation and analog display. Display of Results - Single-channel (with optional display of correction frequency) or dual channel. Absolute Readout - W, dBm, V, dBµV. Relative Readout NRVS, URV55 - Analog Display - Automatic or with selectable scale. Digital Display and Resolution - Max. 4 1/2 digits, resolution selectable (0.1/0.01/0.001 dB). Display Filtering - Averaging over 1 to 512 readings to reduce display noise; manual or automatic setting depending on measurement range and resolution. Display Noise - See sensors from page xxx/xxx. Measurement Rate - See table below. Accuracy of URV55 (without sensor) - 18 to 28°C: ±0.02 dB ± 1 digit. 10 to 40°C: ±0.04 dB ± 1 digit. 0 to 50°C: ±0.06 dB ± 1 digit. Accuracy of Power Readout in W (NRVS/D without
sensor) - Zero Adjustment - Manual or via IEC/IEEE bus, duration approx. 4 s. Frequency Response Correction - Sensor-specific calibration data taken into account; numerical entry of test frequency (keyboard or via IEC/IEEE bus) or by frequency-proportional DC voltage. Attenuation Compensation - External attenuation or gain taken into account; data entry via keyboard or IEC/IEEE bus, range ±200 dB. Entry of Reference Value - Measured value on keystroke or numerical entry via keypad or IEC/IEEE bus. Reference Impedance - For conversion between voltage and power, automatic readout of reference impedance from sensor data memory or numerical entry via keyboard or IEC/IEEE bus (for RF probe). Remote Control - IEC 625 (IEEE 488), control of all instrument functions. Interface Functions - SH1, AH1, T6, L4, SR1, RL1, DC1, DT1, PP0. DC Frequency Input - URV55, NRVS: Standard. NRVD: Option NVRD-B2. Connector: BNC. Input Voltage Range: ±12 V, linear with selectable scale. DC Output - URV55, NRVS: Standard. NRVD: Option NRVD-B2. Connector: BNC, Rout = 1 kiloohm.
Left-/Right-hand Full-scale Value - Corresponding to 0/+3 V. Accuracy - ±5 mV. Channels - 1, 2. Input/Output Option NRVD-B22 simultaneous DC voltage outputs, DC frequency input, trigger input (TTL, active low), ready output (TTL, active high). Sensor Check SourceURV55, NRVS - Option NRVS-B1. NRVD - Standard. Output Power - 1 mW ±0.7%. Frequency - 50 MHz. VSWR - 1.05, <1.03. RF Connector - N female. General Data
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Filter Number |
|||||||||||||
Resolution |
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| NRV-Z1 to -Z15 | 0.045 | 0.05 | 0.06 | 0.08 | 0.15 | 0.27 | 0.49 | 0.95 | 1.85 | 3.6 | 7.2 | 14.5 | 28.5 |
| NRV-Z31 (mod. 02) | 1.04 | 1.04 | 1.05 | 1.07 | 1.13 | 1.24 | 1.44 | 1.84 | 2.7 | 4.3 | 7.5 | 14.0 | 27.0 |
| NRV-Z1 to -Z33 (mod. 03, 04) | 0.135 | 0.14 | 0.15 | 0.17 | 0.23 | 0.34 | 0.54 | 0.94 | 1.77 | 3.4 | 6.6 | 13.0 | 26.0 |
| NVR-Z32 (mod. 05) | 0.435 | 0.44 | 0.45 | 0.47 | 0.53 | 0.64 | 0.84 | 1.24 | 2.07 | 3.7 | 6.9 | 14.0 | 27.0 |
| NRV-Z51 to -Z55 | 0.115 | 0.12 | 0.13 | 0.15 | 0.21 | 0.32 | 0.52 | 0.92 | 1.75 | 3.4 | 6.6 | 13.0 | 26.0 |
| URV 5-Z2, -Z4, -Z7 | 0.065 | 0.07 | 0.08 | 0.01 | 0.02 | 0.38 | 0.72 | 1.45 | 2.80 | 5.5 | 11.0 | 22.0 | 44.0 |
Dimensions |
mm |
in. |
| Height | 147 | 5.8 |
| Width | 219 | 8.6 |
| Depth | 350 | 13.8 |
Weight |
kg |
lbs. |
| Net | 4.5 | 9.9 |
|
|||||
|
|||||