Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
MetricTest Equipment Logo   Advanced
1.800.417.4370
 
Overview
NRVS
More Rohde & Schwarz Products
Rohde & Schwarz on Sale
Other Brands
Home > Rohde & Schwarz > NRVS

Rohde & Schwarz NRVS Power Meter

Characteristics

Measurement Functions - Average power, pulse power, peak envelope power.
AM Reflection, DC voltage (depending on sensor).

Frequency and Level Range - DC to 40 GHz, 100 pW to 30 W.

Probes and Sensors - All NRV sensors and URV5 probes.

Display - LCD for digits, units, menu-guided operation and analog display.

Display of Results - Single-channel (with optional display of correction frequency) or dual channel.

Absolute Readout - W, dBm, V, dBµV.

Relative Readout NRVS, URV55 -
dB, %W or %V relative to a stored reference value.

Analog Display - Automatic or with selectable scale.

Digital Display and Resolution - Max. 4 1/2 digits, resolution selectable (0.1/0.01/0.001 dB).

Display Filtering - Averaging over 1 to 512 readings to reduce display noise; manual or automatic setting depending on measurement range and resolution.

Display Noise - See sensors from page xxx/xxx.

Measurement Rate - See table below.

Accuracy of URV55 (without sensor) -

18 to 28°C: ±0.02 dB ± 1 digit.

10 to 40°C: ±0.04 dB ± 1 digit.

0 to 50°C: ±0.06 dB ± 1 digit.

Accuracy of Power Readout in W (NRVS/D without sensor) -
0.4% + 1 digit (18 to 28°C).
0.9% + 1 digit (10 to 40°C).
1.4% + 1 digit (0 to 50°C).

Zero Adjustment - Manual or via IEC/IEEE bus, duration approx. 4 s.

Frequency Response Correction - Sensor-specific calibration data taken into account; numerical entry of test frequency (keyboard or via IEC/IEEE bus) or by frequency-proportional DC voltage.

Attenuation Compensation - External attenuation or gain taken into account; data entry via keyboard or IEC/IEEE bus, range ±200 dB.

Entry of Reference Value - Measured value on keystroke or numerical entry via keypad or IEC/IEEE bus.

Reference Impedance - For conversion between voltage and power, automatic readout of reference impedance from sensor data memory or numerical entry via keyboard or IEC/IEEE bus (for RF probe).

Remote Control - IEC 625 (IEEE 488), control of all instrument functions.

Interface Functions - SH1, AH1, T6, L4, SR1, RL1, DC1, DT1, PP0.

DC Frequency Input -

URV55, NRVS: Standard.

NRVD: Option NVRD-B2.

Connector: BNC.

Input Voltage Range: ±12 V, linear with selectable scale.

DC Output -

URV55, NRVS: Standard.

NRVD: Option NRVD-B2.

Connector: BNC, Rout = 1 kiloohm.
EMF proportional to analog display.

Left-/Right-hand Full-scale Value - Corresponding to 0/+3 V.

Accuracy - ±5 mV.

Channels - 1, 2.

Input/Output Option NRVD-B2

2 simultaneous DC voltage outputs, DC frequency input, trigger input (TTL, active low), ready output (TTL, active high).

Sensor Check Source

URV55, NRVS - Option NRVS-B1.

NRVD - Standard.

Output Power - 1 mW ±0.7%.

Frequency - 50 MHz.

VSWR - 1.05, <1.03.

RF Connector - N female.

General Data

Power Supply - 115 V + 15/-22% (-15%).
47 to 63  (440) Hz;, 230 V + 15/-22%, 47 to 63 Hz, 13 VA.

Measurement Time in Seconds (From Trigger to Output of First Byte), Depending Upon Filter Setting


Filter Number

Resolution

0 1 2 3 4 5 6 7 8 9 10 11 12
NRV-Z1 to -Z15 0.045 0.05 0.06 0.08 0.15 0.27 0.49 0.95 1.85 3.6 7.2 14.5 28.5
NRV-Z31 (mod. 02) 1.04 1.04 1.05 1.07 1.13 1.24 1.44 1.84 2.7 4.3 7.5 14.0 27.0
NRV-Z1 to -Z33 (mod. 03, 04) 0.135 0.14 0.15 0.17 0.23 0.34 0.54 0.94 1.77 3.4 6.6 13.0 26.0
NVR-Z32 (mod. 05) 0.435 0.44 0.45 0.47 0.53 0.64 0.84 1.24 2.07 3.7 6.9 14.0 27.0
NRV-Z51 to -Z55 0.115 0.12 0.13 0.15 0.21 0.32 0.52 0.92 1.75 3.4 6.6 13.0 26.0
URV 5-Z2, -Z4, -Z7 0.065 0.07 0.08 0.01 0.02 0.38 0.72 1.45 2.80 5.5 11.0 22.0 44.0

Physical Characteristics

Dimensions

mm

in.

Height 147 5.8
Width 219 8.6
Depth 350 13.8

Weight

kg

lbs.

Net 4.5 9.9
 
 
  Company    |   Contact Us   |   Site Map 1.800.417.4370
 
 
 
 