Home >
Tektronix > Logic Analyzer Probes
Tektronix Logic Analyzer Probes
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
P6810![]() |
P6860![]() |
P6880![]() |
P6417![]() |
P6418![]() |
P6434![]() |
|
| Logic Analyzer Used | TLA7AAx Logic Analyzer Modules TLA7ABx Logic Analyzer Modules |
TLA6xx Logic Analyzers TLA7Lx/7Mx Logic Analyzer Modules TLA7Nx/7Px/7Qx Logic Analyzer Modules |
||||
| Recommended Use | Recommended for most general-purpose uses that require maximum flexibility for single-ended or differential requirements | Recommended for applications requiring many channels to be quickly connected in a small footprint | Recommended for applications requiring many differential channels to be quickly connected in a small footprint | Recommended for most general-purpose uses that require maximum flexibility | Recommended for most general-purpose uses | Recommended for applications requiring many channels to be quickly connected in a small footprint |
| Attachment to Target System | Probe leadsets adapt to industry standard interfaces; leads spread over a wide area | Connectorless "compression" contact (Adapter for Mictor connector available) | Connectorless "compression" contact (Adapter for Mictor connector available) | Probe leadsets adapt to industry standard interfaces; leads spread over a wide area | Probe leadsets adapt to industry standard interfaces | AMP Mictor 34 channel connector (Adapter to use P6434 with P6860/80 high-density compression land footprint available) |
| Probe Type | General purpose, 34 channel active probe | High density, 34 channel active probe | High density, 34 channel active differential probe | General purpose, 17 channel passive probe |
General purpose, 17 channel passive probe |
High density, 34 channel passive probe AMP Mictor connector required |
| Pin Spacing Supported | 0.100 in. and 2 mm | N/A | N/A | 0.100 in. | 0.100 in. | N/A |
| Logic Signals Supported | Differential Clock Differential Data |
Differential Clock Single-ended Data |
Differential Clock Differential Data |
Single-ended Clock and Data (Differential signal adapters available) | Single-ended Clock and Data (Differential signal adapters available) | Single-ended Clock and Data |
| Simultaneous State/ Timing to: |
800 MHz/ 8 GHz |
800 MHz/ 8 GHz |
800 MHz/ 8 GHz |
200 MHz/ 2 GHz |
200 MHz/ 2 GHz |
200 MHz/ 2 GHz |
| Simultaneous State/Timing/ Analog to: |
800 MHz/ 8 GHz/ 2 GHz |
800 MHz/ 8 GHz/ 2 GHz |
800 MHz/ 8 GHz/ 2 GHz |
N/A | N/A | N/A |
| Minimum Signal Amplitude Minimum Single-ended |
300 mVp-p | 300 mVp-p | 300 mVp-p | 500 mVp-p | 500 mVp-p | 500 mVp-p |
| Minimum Differential |
Vmax - Vmin>150 mV | Vmax - Vmin>150 mV | Vmax - Vmin>150 mV | N/A | N/A | N/A |
| Probe Load AC/DC |
1.2 pF/20 kOhm to Ground | 0.7 pF/20 kOhm to Ground | 0.7 pF/20 kOhm to Ground | 2 pF/20 kOhm to 2.2 V (Low-voltage adapters that work with low-voltage signals are available) | 2 pF/20 kOhm to 2.2 V (Low-voltage adapters that work with low-voltage signals are available) | 2 pF/20 kOhm to 2.2 V |
| Notes | Works with a wide-range of industry-standard accessories for flexible attachment to your target system | No connector required - only land pads required to be laid out on target system PCB for 17 and/or 34 channels. Please refer to P6860/6880 probe design guide | No connector required - only land pads required to be laid out on target system PCB for 17 and/or 34 channels. Please refer to P6860/6880 probe design guide | Works with a wide-range of industry-standard accessories for flexible attachment to your target system | Works with a wide-range of industry-standard accessories for flexible attachment to your target system | Requires AMP Mictor connector to be installed on target system PCB for every 34 channels. Please refer to P6434 probe manual |
|
|||||
|
|||||