Tektronix 11801C Digital Sampling Oscilloscope
Features
- DC To 50 Ghz Bandwidth
- 7 Ps Rise Time
- Eight Channels, Expandable to 136 (with SM-11 multi-channel units)
- High Resolution and Measurement Repeatability
- 10 Femtosecond Sampling Interval (0.01 ps)
- Modular Architecture
- Dual Timebase Allows Multiple Windows
- FFT
- Predefined Telecom Masks
- True Dual-Step Differential TDR
- Fully Automatic Jitter and Noise Measurements
- Automatic Statistical Measurements, Histograms and Mask Testing
- Automatic Pulse Measurements with Statistics
- Comprehensive Waveform Processing
- Complete Programmability for ATE Applications
- Color Display with Color Grading
Applications
- Semiconductor Test
- TDR Characterization
- High Speed Digital
- Data Communication
The 11801C Digital Sampling Oscilloscope
The 11801C Digital Sampling Oscilloscope offers the widest
range of on-board measurement and waveform processing capabilities of
any multi-Gigahertz scope. With excellent measurement repeatability, exceptional
vertical resolution and fast display update rate, the 11801C is a powerful
measurement tool for semiconductor testing, TDR characterization of circuit
boards, IC packages and cables, and high speed digital data communications.
Modularity Meets Your Needs Now and in the Future
The modular microprocessor-based architecture of the 11801C
not only allows you to select the right configuration for your application,
but also allows expandability to meet your future measurement needs. The
11801C accepts up to 4 dual-channel sampling heads and can be expanded
through the SM-11 Multi-Channel Units to 136 channels. There are currently
nine sampling heads to choose from:
SD-14 3 GHz high impedance (100 kilohm/0.475 pF) dual-channel
probe sampler
SD-20 20 GHz single-channel loop-through head
SD-22 12.5 GHz dual-channel low noise head
SD-24 20 GHz dual-channel TDR/sampling head
SD-26 20 GHz dual-channel sampling head
SD-32 50 GHz, single-channel sampling head
SD-42 6.4 GHz O/E converter (55 ps optical pulse response
FWHM)
SD-44 15 GHz O/E converter
SD-51 20 GHz trigger head
Specifications
Vertical Systems
Rise Time/Bandwidth - Determined
by the sampling head used.*1
Vertical Resolution - 8 bits full
screen (78 µV LSB at 2 mV/div deflection factor).
Amplifier Gain Accuracy - ±1%
of all settings.
Deflection Factors - 2 to 255 mV/div
in
1 mV/div increments.
Offset Range - ±2 V.
Horizontal System
Main and Window Time Base - 1 ps/div
to 5 ms/div, settable in 1-2-5 sequence or in 1 ps increments.
Time Interval Accuracy - 8 ps
+ 0.01% x (interval) + 0.001% x (position), guaranteed;
4 ps + 0.004% x (interval) + 0.0004% x (position), typical, where
interval >/=1 ns;
2.5 ps + 0.0004% x (position), typical, where interval = 100 ps;
1 ps + 0.0004% x (position), typical, where intervals <10 ps.
Notes: 1) For intervals <100 ps,
the above holds for time/div </=20 ps/div.
2) For other intervals not listed above, linearity interpolate the cardinal
points.
Record Length - 512, 1024, 2048,
4096, and 5120 samples.
Windows - Any number of window records
may be placed on any number of main records, up to a maximum of 8 displayed
traces. All window records have the same duration, but may be independently
positioned on any main record. Windows may be set to automatically track
a moving edge on the main record.
Maximum Sampling Rate - 200 ks/s.
Trigger System*2
Trigger Bandwidth - Direct 4 GHz
typical, Prescaled 12.5 GHz typical.
Trigger Sensitivity - Direct DC
to 4 GHz: 50 mV typical.
Prescaled 2 to 10 GHz: 500 mV,
10 to 12.5 GHz: 800 mV typical.
Delay Jitter - 1.1 ps +4 ppm
of a position typical. 2.0 ps +5 ppm of position
maximum (RMS).
Metastability: Raw <0.005 ppm
at 2.488 GHz with 200mV input trigger voltage, typical.
Enhanced is theoretically zero.
Internal Clock - 100 kHz (drives
TDR, Internal Clock Output, and Calibrator).
Trigger Level Range - ±1.0 V
(±10 V with 10X trigger attenuator activated).
Trigger Input Range - ±1.5 V
(±1.5 V, 5 V
RMS maximum with 10X).
Trigger Holdoff - 5 µs
to 2.5 s.
Measurement System
Waveform Processing Functions -
Add, subtract, multiply, divide, absolute, average, differentiate, envelope,
exponent, integrate, natural log, log, signum, square root, smoothing,
and filter.
Measurement Set - Max, min, mid,
p-p, mean, RMS, amplitude, extinction ratio, overshoot, undershoot, noise*3,
rise, fall, spectral magnitude, spectral frequency, THD, SNR, frequency,
period, prop delay, cross, width, phase, duty cycle, jitter*3,
area +, area -, and energy. Measurements are constantly updated;
mean and standard deviation available on all measurements.
Measurement Parameters - (Proximal,
mesial, distal, and start/stop levels): May be set to absolute levels.
Cursors - Paired or split dots,
vertical bars, and horizontal bars.
TDR System (SD-24 Only)
Combined TDR/Acquisition Reflected
Risetime - 35 ps or less.
TDR Step Amplitude - Adjustable
to ±250 mV (polarity of either step may be inverted).
Time Coincidence Between TDR Steps
- Adjustable to less than 1 ps.
Source Resistance - 50 ±0.5 Ohm.
Typical Aberrations (at ±250 mV
Amplitude) - 10 ns to 20 ps before step: ±3% or less;
less than 300 ps after step: +10%, -5% or less;
300 ps to 5 ns after step: ±3% or less; elsewhere: ±1%
or less.
CRT and Display Features
CRT - 9 in. diagonal, magnetic deflection,
vertical raster scan orientation. Color.
Colors - Eight-color default color
set included; or, colors are user-selectable from palette of 262,144 colors.
Video Resolution - 552 horizontal
by 704 vertical displayed pixels.
Power Requirements
Line-Voltage Ranges - 90 to 132 V
RMS, 180 to 250 V RMS.
Line Frequency - 48 to 440 Hz.
Maximum Power Consumption - 214
W.
Environmental and Safety
Temperature - Operating: 0°C
to +50°C; non-operating: -40°C to +75°C.
Humidity - Operating and nonoperating:
up to 95% relative humidity, up to 50°C. Per Mil-T-28800E, Type III,
Class 5.
Altitude, Vibration, Shock
non-operating, Bench Handling - Meets MIL-T-28800E, Type III, Class 5.
Electromagnetic Compatibility (with
sampling heads or optional blank panels installed in all sampling head
compartments) - Meets the requirements of: MIL-STD-461B; FCC Part 15,
sub-part J, Class A; VDE 0871/6.78 Class B.
Safety - Listed UL 1244, CSA Bulletin
556B September 1973.
Physical Characteristics
|
|
|
Cabinet
|
|
Rackmount
|
|
|
|
Dimensions
|
mm
|
in.
|
mm
|
in.
|
|
11801C
|
Width
|
448
|
17.6
|
483
|
19.0
|
|
|
Height
|
238
|
9.4
|
222
|
8.8
|
|
|
Depth
|
599
|
23.6
|
550
|
21.6
|
|
SM-11
|
Width
|
448
|
17.6
|
483
|
19.0
|
|
|
Height
|
238
|
9.4
|
222
|
8.8
|
|
|
Depth
|
558
|
22.0
|
550
|
21.6
|
|
|
Weights
|
kg
|
lb.
|
kg
|
lb.
|
|
11801C
|
Net
|
22.3
|
49.0
|
23.2
|
51.0
|
|
|
Shipping
|
25.9
|
57.0
|
26.8
|
59.0
|
|
SM-11
|
Net
|
20.0
|
44.0
|
20.9
|
46.0
|
|
|
Shipping
|
23.6
|
52.0
|
24.5
|
54.0
|
Ordering Information
11801C
Digital Sampling Oscilloscope
Includes: User Manual (070-9971-00);
Programmer Manual (070-9970-00);
Service Manual (070-9972-00);
12-inch SMA-SMA cable,
2 ea. 8-1/2-inch SMA-SMA cable,
1 wrist strap.
Opt 1M - Multi-Channel Conversion: Modifies
11801C to permit operation with up to four SM-11 Multi-Channel Units.
Opt 1R - Rackmount.
Includes: Hardware, tooling, and instructions
for converting bench model to rackmount configuration. Available with
11801C.
DL-11
Delay Line
Includes: Delay Line Instruction Sheet
- Order 070-7051-01.
International Power Plug Options
Option A1-A5 - Available.
Additional Accessories
Sampling Head Extender Cable, 1 meter - 012-1220-00.
Sampling Head Extender Cable, 2 meter - 012-1221-00.
DL-11 Service Manual - 070-7050-01.
Blank Panel for Empty Sampling Head Compartments
- 200-3395-00.
ECL Terminator - 015-0558-00.
SMA Accessory Kit - 020-1693-00.
Recommended Probes
P6150 - 9 GHz Passive Pr
|