TEK 1730 Waveform Monitor (NTSC)
Features
- Performance and Economy
- Full Frame Line Select
- Simultaneous Channel A and B Display
- Dual Filter Display
- One-button Front Panel Recall
- RGB/YRGB Display Capability
- 1730 Series Displays D-2 Servo Waveforms
- Parallax-free Internal Graticules
- Differential Phase and Gain Measurement
- Stereo Audio Phase Measurement
- Vector Center Dot Clamping
- Remote Control Capability
- Available in NTSC and PAL Standards as Well as Dual Standard
- White Phosphor Available
- SCH Monitoring Available with 1720 SCH Series Vectorscopes
- Composite Serial and Parallel Monitoring Is Available with 1730 D
Series
Applications
The Tektronix 1730 Series Waveform Monitors and 1720 Series Vectorscopes
provide comprehensive television signal monitoring for both NTSC and PAL
applications. These versatile instruments are light weight, half-rack
width and have bright CRTs for video signal monitoring. Both instruments
exceed normal monitoring capabilities, and their unique features make
them even more powerful when operated in tandem. Each monitor has its
own advanced feature set and the proven 1700 Series family performance
to provide more monitor for the money. These monitors do the job faster,
better and easier at an economical price.
The 1720 Series and 1730 Series families cover a wide variety
of video testing needs. For typical composite monitoring in the NTSC and
PAL realm, the 1720 Series and 1730 Series more than handle the job. If
there is a need for Dual Standard testing (PAL and NTSC), the 1735 Waveform
Monitor and 1725 Vectorscope can be used. For SCH capability, the
1720 SCH Series of vectorscopes are an economical solution. Digital testing
of both Composite Parallel and Composite Serial can be accomplished with
the 1730 D Series of Digital Waveform Monitors. Whatever the individual
video testing application, the 1720 and 1730 Series family provide an
easy to use, economical solution.
Complete Line Select
The 1730 Series Waveform Monitor has full frame line select,
with alphanumeric readout, that can be tracked by the 1720 Series Vectorscope
when in Auxiliary mode. Any one or two lines of the entire frame can be
selected and displayed or the same line(s) in both fields can be viewed
at one time. An intensified zone in the two-field sweep and on the picture
monitor output signal indicates the location of the line selection. In
addition, any successive 15 lines can be overlaid for camera and VTR
adjustments.
Simultaneous Channel A and B Display
These instruments have microprocessor front panel control.
They are operator-friendly and provide outstanding features in half-rack
waveform monitors or vectorscopes. Both the 1730 Series Waveform Monitor
and the 1720 Series Vectorscope have dual channel display capability,
allowing both input channels to be displayed on the CRT simultaneously.
Dual Filter Display
The 1730 (NTSC) and the 1731 (PAL) Waveform Monitor include
dual filter display, which provides low pass and flat information in the
same display. The 2-Field and 2-Line Display Modes have the Low Pass Filter
applied to the left half of the trace. In the 1-Line Mode, the two signals
are overlaid. These filter modes can also be used independently. Both
versions of the 1730 Series have chroma filters centered around the subcarrier
frequency.
One-button Front Panel Recall
Once the front panel has been set up in a frequently used
mode, the configuration can be stored for later one-button recall. In
addition, when the 1720 is used in tandem with the 1730, it will respond
to this Store/Recall operation. Up to four operator-selected front panel
configurations can be stored from the front panel. Four other front panel
configurations are factory-programmed settings and are accessible from
the Remote Control interface.
Differential Phase and Gain Measurements
The 1720 Series Vectorscope graticule has scales for
measuring Differential Phase and Gain. The Differential Phase scale has
markings at 2° intervals. The Differential Gain scale has markings
at 5% intervals. For even greater precision, the 1720 and 1730 Series
can be coupled for differential phase measurements using the field or
line sweep on the 1730 Series Waveform Monitor. The Waveform Monitor Chroma
filter can be used for differential gain measurements.
Stereo Audio Phase Measurements
Balanced inputs for the X Y mode are available on the 1720
Series Vectorscope through a separate input connector. This mode
is particularly useful for evaluation of stereo audio with a special X
Y graticule scale for both amplitude and phase measurements. X Y measurements
can be displayed individually or in combination with a vector display.
This input can also be used for other applications where X Y monitoring
is useful.
Polar Display of Relative and Absolute SCH Phase (1720 SCH Series Only)
The absolute and relative SCH polar displays makes the 1720
SCH series ideal for the editing suite. In the two dot absolute SCH mode,
the 1720 SCH series accurately display the subcarrier to horizontal phase
relationship of the input signal. In the one dot relative mode, the SCH
relationship is measured against an external reference signal. This makes
matched frame editing sequences easy to verify.
RGB-YRGB
The Waveform Monitor can display RGB or YRGB. The RGB/YRGB
staircase input is through a rear panel connector.
Vector Center Dot Clamping
The 1720 Series Vectorscopes employ center dot clamping
in Vector mode for easy detection of residual sub-carrier on the
signal. In addition, with no signal present, the center dot automatically
dims prolonging the CRT life.
Parallax-free Internal Graticules
Both instruments utilize post-accelerated, mesh-type CRTs
equipped with internal graticules to provide parallax-free displays. Variable,
evenly-illuminated scales, along with molded bezels, make waveform photography
a snap.
Remote Control
Internal front panel presets, RGB/YRGB enable, along with
front panel recall/setup can be accessed through the waveform monitor
remote connector.
Available in NTSC, PAL and Dual Standard
Both the 1730 Series and the 1720 Series are available in
either NTSC or PAL versions. The 1721 Vectorscope and the 1731 Waveform
Monitor are the PAL versions. The 1730D monitors digital and analog NTSC
signals. The 1735 Waveform Monitor and 1725 Vectorscope provide PAL/NTSC
Dual Standard Monitoring. PAL-M and PAL-N instruments are available as
a modified product.
Specifications
1730 Series Waveform Monitors Characteristics Signal Input (Video and
External Reference)
Return Loss - >40 dB, 50 kHz
to 6 MHz, power on or off.
Maximum Input - ±5 V
DC + peak AC.
Loop-through Isolation - >80 dB
at FSC.
Channel Isolation - >50 dB
at FSC.
Impedance - >15 kilohm.
Vertical Deflection
Deflection Factor - Within 1% of
1 V.
Gain Range - Input signals between
0.8 V and 2 V can be adjusted to a 1 V display; (160 mV
and 400 mV for X5 gain).
Position Range - 1 V signal
can be positioned so that peak white and sync tip can be placed at blanking
level regardless of gain range.
Frequency Response
Flat - 50 kHz to 6 MHz
within 2% (X1), within 5% (X5).
Low Pass - 40 dB attenuation
at FSC; Low pass response within 1% of flat response (1735:
30 dB).
Chroma - Nominal bandwidth 1 MHz;
2X FSC attenuation >20 dB; Chroma response within 1%
of flat response.
Transient Response
Preshoot - <
1%.
Overshoot - <
2%.
Ringing - <
2%.
Tilt - <
1%.
Pulse-to-bar Ratio - 0.99:1 to 1.01:1.
Differential Gain - <
1%.
DC Restoration
Clamp Time - Back porch.
Frequency Response - Attenuation
of 60 Hz on input signal:
Slow mode: <
20%.
Fast mode: >90%.
Blanking Level Shift - A 10% to
90% APL change will cause <
1% of blanking level shift. Presence or absence of color burst will cause
<
1% of blanking shift.
PIX Monitor Output
Frequency Response - 50 kHz
to 6 MHz within 3%.
Differential Gain - <
1%.
Differential Phase - <
1%.
DC Level on Output - <
0.5 V into 75 Ohm load.
Intensification (Brightup) - 180 mV
DC offset on select lines.
Output Impedance - 75 Ohm nominal.
Return Loss - >30 dB, 50 kHz
to 6 MHz.
Input to Output (PIX MON) Gain Ratio
Luminance - 1:1 ±5% at 15 kHz.
Calibrator
Frequency - 100 kHz ±
0.1 kHz.
Timing Accuracy - 10 µs,
±0.01 µs.
Amplitude - 1 V, ±1%.
Horizontal Deflection System
Sweep - Sweep will occur with or
without input signal.
1-Line Repetition Rate - Equal to
applied line rate, magnification equals 0.2 ms/div.
2-Line Repetition Rate - Equal to
half applied line rate, magnification equals 1 ms/div.
2-Field Repetition Rate - Equal
to applied frame rate, magnification equals approximately X25.
Timing Accuracy -
1 ms/div.: Within 2%.
0.2 ms/div.: Within 3%.
Linearity - Within 2%.
Differential Linearity - Within
2%.
Sweep Magnification Registration
- Magnification occurs about the center of the screen.
Position Range - Any portion of
a synchronized video sweep can be positioned on screen in all sweep modes.
Synchronization
Internal - Composite video or black
burst with sync ±6 dB of nominal.
External - Sync amplitude of 143 mV
to 4 V.
Remote Sync - 2.0 to 5.0 V
square wave or 4.0 V comp sync (sync polarity can be internally inverted).
RGB/YRGB -
Repetition rate: Field rate and line rate with magnification of X25 and
X10, respectively.
Sweep length:
3-Step (RGB): 3.4 to 4.1 divs.
4-Step (YRGB): 2.5 to 3.1 divs.
Ordering Information
TEK 1730 Waveform Monitor (NTSC)
When ordering, please use exact nomenclature given here. The standard
instruments are shipped without a case or handle. If your application
is for bench or portable use, please order the appropriate enclosure
from the optional accessories list. The 1720, 1720 SCH, 1721, 1721 SCH,
1725, 1730, 1731 and 1735 are UL-recognized components and meet the
requirements for listing when used in the appropriate enclosure.
1730
Waveform Monitor (for NTSC System Applications).
All Include: Instruction Manual, Power
Cable Assembly, Spare Fuse, Auxiliary Control Cable 012-1422-01 (1720
Series only).
Opt. 74 - Substitute P4 (white) phosphor
on CRT.
Optional Accessories
1700F00 - Cabinets Plain (painted silver
grey).
1700F02 - Portable (including handle, feet
and front cover, painted silver grey).
1700F05 - Side-by-side Rack Adapter.
1700F06 - Blank Half-rack Width Panel.
Viewing Hood - Order 016-0475-00.
Snap-on Front Cover - Order 200-3897-01.
|