TEK AD007 GPIB-LAN Adapter
Features
- Control Tektronix Oscilloscopes and Other Instruments via a LAN-Based
(Ethernet) TCP/IP Network PC
- Interface Up to 14 GPIB Devices to Each AD007
- Talk to Several GPIB Instruments/Systems from Several Networked PCs
- Print to Networked Printers
- Ethernet Twisted Pair (10BaseT) Adapter
- Operates on All Windows 95/98 and NT 4.0 Operating Systems
- Compatible with WaveStar for Oscilloscopes Applications Software and
Custom, Proprietary Programs (C, C++, or Microsoft Visual Basic)
- Compact Size
- Web Page-Based Configuration and Statistics
Applications
- Digital Design
- Research and Development
- Manufacturing Test
- Service and Support
- Education
Instrument to Local Area Network (LAN) Connectivity
Control your Tektronix TDS Series oscilloscope from any networked PC.
Check on its status, or capture waveforms any time you want from your
office, another site, or from anywhere using WaveStarTM application
software or your own software. Or command your TDS Series oscilloscope
to print to a networked printer.
The Tektronix GPIB-LAN Adapter takes advantage of the fact that many
of today's computers are connected together through an Ethernet 10BaseT
LAN.
Print to Networked Printers
Using any web browser, select the networked printer to which your TDS
Series oscilloscope will print and route your hardcopy output to your
high quality monochrome or color networked printer.
Windows 95/98 Or NT 4.0 Compatibility
You don't need to understand or program Ethernet protocols. Both communications
and Virtual Instrument Software Architecture (VISA) software for
Windows 95/98 or NT 4.0 is included free with the GPIB-LAN Adapter. Now,
you can also perform waveform capture from your TDS Series oscilloscopes
across the LAN by using Tektronix WaveStar for Oscilloscopes application
software. Or write a program using C, C++, or Microsoft Visual Basic
to capture data or control your instrument. As long as the program is
written using the standard VISA interface, the GPIB-LAN Adapter's
software will turn your PC into a GPIB Talker, Listener, Controller.
Network Details
The AD007 implements a full range of adapter functions and Ethernet-based
TCP/IP protocols. It operates with all of the popular network protocols
such as BOOTP, DHCP, DNS, LPD, HTTP, and FTP.
Configuration and Statistics
Use a web browser to configure features; examine GPIB commands, Ethernet
traffic statistics, and GPIB traffic statistics; and initiate diagnostic
GPIB commands.
Ease of Installation
Simply connect your AD007 to your LAN with the cable provided, connect
the GPIB interface to your instruments, and power up the unit. It automatically
requests an IP address from the network's Boot Server, or this can be
manually entered using the adapter’s internal web page. Upon power-up,
the unit also performs hardware diagnostics/self-test. Status indicators
on the unit give evidence of successful completion of this testing, connection
to the LAN, and both LAN and GPIB traffic.
Any number of AD007 Adapters may be used to connect any combination of
GPIB devices to the network. (NOTE: Limit of 14 devices per GPIB cluster.)
SpecificationsSystem Requirements
Computer Type - IBM PC-compatible with Windows
95/98 or NT 4.0 Operating System. Consult Microsoft documentation for
recommended configuration.
Hard Disk - 5 Mbytes or greater.
RAM - Consult Microsoft documentation for recommended
minimum configuration.
CD-ROM - Required.
NOTE: For printing only a web browser is required.
Network Compatibility
Ethernet Port - 10BaseT, RJ-45 connector.
Protocols - BOOTP, DHCP, LPD, DNS, HTTP, FTP.
Networked Printer -
Compatibility: Must be compatible with the GPIB instrument's hardcopy
output format.
Print Protocol: Must support LPD Network Print protocol.
IEEE 488 (GPIB) Compatibility
Connection - No cable required for most applications.
Compatibility - Fully IEEE488.2 compatible.
NOTE: Not suitable for connection to the public telecommunications (telephone)
network.
Other
Transmission Rate - Up to 10 Mbps on Ethernet;
dependent on slowest GPIB device on the bus.
Front-Panel Indicators - Power, LAN-Link, LAN,
GPIB.
Environmental
Temperature -
Operating: 0 to +45°C.
Non-operating: –20 to +70°C.
Humidity - 30 to 45°C, 90 to 95%, relative
humidity.
Altitude -
Operating: Up to 2,000 m (6,500 ft.).
Non-operating: Up to 10,000 m (33,000 ft.).
Vibration - 3 axis, 60 minutes total, 20 minutes/axis
(10 minutes operating, 10 minutes non-operating).
Shock - Half sine, 500 g, 3 axis, 3 drops each
axis.
EMC Compliance
Meets the intent of EMC Directive 89/336/EEC.
Complies with FCC Part 15, Class A limits.
Safety Compliance (Power Supply)
EN60950 (CE Mark).
UL1950.
CAN/CSA 22.2 No. 950.
DENTORI (T-MARK).
Power
Source Power -
Voltage Ranges: 100 to 240 VAC ±10%.
Line Frequency: 50 to 60 Hz.
Power Consumption - Regulated 5 VDC at 300 mA,
typical.
Physical Characteristics
| Dimensions |
mm |
in. |
| Height |
35.6 |
1.4 |
| Width |
76.2 |
3 |
| Depth |
120.2 |
4.7 |
| Weight |
kg |
lb. |
| Net |
0.15 |
0.34 |
Ordering Information
AD007
GPIB-LAN Adapter.
Includes: Adapter, Regulated Power Supply, CD-ROM