TEK P5100 Passive High Voltage Probe
Features
The P5100 is a low-input capacitance High Voltage (2.5 kV) Probe
designed for higher frequency applications. The probe can be compensated
to match plug-ins and oscilloscopes with nominal input capacitances of
7-30 pF. A variety of screw-on accessories provide easy connection to
the device under test. For additional information on P5100, request Data
Sheet 56W-10262-1.
P5102 IsolatedChannelTM Applications
In many applications, it is important to be able to isolate the measurement
from earth ground and also to isolate the common voltage between channels.
With the P5102 and the THS 700 Series handheld digital storage oscilloscopes
you have not only the isolation for the measurement from earth ground,
but you also have full isolation between the two channels.
The P5102 was designed to give you this isolated channel performance
for up to 1000 V AC RMS on the 100 MHz probe. A variety of screw-on accessories
provides easy connection to the device under test.
For heavy-duty high-performance measurements of voltages over 2.5 kV,
the P6015A is the industry standard. You can measure DC voltages up to
20 kV and pulses up to 40 kV. The 75 MHz bandwidth enables you to
capture fast, high-voltage signals.
The P6015A uses an environmentally safe silicone compound for a dielectric
and never needs refilling. Other features include: a 7-49 pF compensation
range, small compensation boxes which fit on adjacent amplifier inputs
and a readout option for use with Tektronix digital scopes. With the readout
option, displayed voltage amplitude values will be the actual signal value
rather than understated by a factor of 1,000. Using the readout version
with other than Tektronix digital scopes may result in an erroneous readout
display. For additional information on the P6015A, request P6015A Data
Sheet 51W-8217-1.
- DC to 250 MHz
- 2500 V DC + Peak AC
- 100X with Readout
- UL 3111-1 Listed
- EC 1010 Certified
- 7-30 pF Compensation Range
- 100 MHz
- 10X
- For THS 700 Series
- IEC 1010 Certified
- UL 3111-1 Listed
Specifications
| Probe |
Nominal
Length |
Attenuation |
Bandwidth |
Risetime |
Loading |
Max
Input V |
in
pF DC or RMS |
Readout |
| P6015A |
10 ft. |
1000X |
75 MHz |
4.0 ns |
100 megaohm/3 pF |
20 kV |
7 to 49 |
No |
| P6015A Opt.
1R |
10
ft. |
1000X |
75 MHz |
4.0 ns |
100 megaohm/3
pF |
20 kV |
7 to 49 |
Yes |
| P6015A Opt. 25 |
25 ft. |
1000X |
25 MHz |
14 ns |
100 megaohm/4 pF |
20 kV |
7 to 49 |
No |
| P6015A Opt.
2R |
25
ft. |
1000X |
25 MHz |
14 ns |
100 megaohm/4
pF |
20 kV |
7 to 49 |
Yes |
| P5100 |
10 ft. |
100x |
250 MHz |
1.75 ns |
10 megaohm/2.75 pF |
2.5 kV |
7 to 30 |
Yes |
| P5102 |
2
m |
10X |
100 MHz |
3.5 ns |
5 megaohm/11.2
pF |
1,000 VRMS |
24 to
28 |
No |
|