TEK TCP202 DC Coupled Current Probe
Features
- Easy Current Measurements
- Probe Connects Directly to TDS Scope through TEKPROBE®
Interface
- Split Core Construction for Easy Circuit Connection
- DC to 50 MHz Bandwidth
- 15 Amps DC + Peak AC Current
- 50 Amps Peak Pulse Current
- 500 x 10-6 Amp*Sec Product
- Safety Certified
Applications
- Motor Drives
- Switching Power Supplies
- Disk Drive
- Electronic Ballasts
- Inverters
- Avionics
TCP202 DC Coupled Current Probe
When combined with a Tektronix TDS oscilloscope, the TCP202
enables users to make direct readout DC and AC current measurements, resulting
in accurate displayed and recorded measurements.
The TCP202 is a general-purpose probe for displaying and
measuring current in electronic circuits. It's ideal for power supply
and motor drive design, and for device testing.
Specifications
Bandwidth - DC to 50 MHz.
Max DC + Peak AC Current - 15 A.
Max Peak Pulse Current - 50 A.
Minimum Sensitivity - 10 mA/div.
DC Accuracy - ±1% (with probe
calibrator).
±3% (without probe calibrator).
Max Bare Wire Voltage - 300 V
(Cat I).
Typical Characteristics
Insertion Impedance - 0.002 Ohm
at 1 kHz.
0.1 Ohm at 5 MHz.
Propagation Delay - 17 ns.
Max Conductor Diameter - 3.8 mm
(0.15 in.).
Electrostatic Immunity - (per IEC
801-2) > 8 kV.
Amp*Sec Product - 500 x 10-6
Amp*Sec.
Rise Time - < 7.0 ns.
Physical Characteristics
Weight - 0.19 kg (0.44 lbs.).
Cable Length - 2.2 m (7.2 ft.).
Power Requirements
TCP202 is powered by the TDS oscilloscope
via the TEKPROBE interface.
Safety
UL 3111-1, CSA1010.1, EN61010-1,
IEC61010-1, EN61010-2-032, IEC61010-2-032.
Recommended Oscilloscopes
TDS 520B; TDS 520C; TDS 520D;
TDS 540B; TDS 540C; TDS 540D; TDS 580C; TDS 580D;
TDS 654C, TDS 680C, TDS 684C, TDS 694C, TDS 724A;
TDS 724C; TDS 724D; TDS 744A (S/N B040100 or higher);
TDS 754A; TDS 754C; TDS 754D; TDS 784A (S/N B040100
or higher); TDS 784C; TDS 784D; TDS 794D.
TDS 744A and TDS 784A with S/N B030XXX or lower can be
upgraded to the latest version using the TDS 7U01 Upgrade Kit.
For TCP202 operation with other TDS 400, TDS 500, TDS 600,
and TDS 700 series oscilloscopes; the scale factor will be correct,
but measurement will be indicated as V instead of A.
Increase the Accuracy of Your Current Measurements
The accuracy of the TCP202 AC/DC
current probe is normally 3%. However, the accuracy may be improved to
1% when the probe is calibrated on the TDS oscilloscope using the optional
Calibrator P/N 015-0672-50. This improved accuracy is available on the
above Recommended Oscilloscopes list.
Specs
Ordering Information
TCP202 DC Coupled Current Probe
Includes: Instruction manual (070-9542-00),
reference manual (070-9543-02).
Recommended Accessories
Probe Calibrator - (015-0672-50) Use with
TDS 510A, TDS 520B, TDS 520C, TDS 520D, TDS 540B,
TDS 540C, TDS 540D, TDS 580D, TDS 654C, TDS 680C,
TDS 684C, TDS 694C, TDS 724A, TDS 724C, TDS 724D,
TDS 754A, TDS 754C, TDS 754D, TDS 784A, TDS 784C,
TDS 784D, TDS 794D for improved accuracy.
TDS 7U01 Upgrade Kit - For TDS 744A and TDS
784A. Please check with your local Tektronix Service Center.
Related Products
1103 - TEKPROBE® Power Supply (for use
with non-TEKPROBE BNC scopes).
ADA400A - Differential Preamplifier.
P5205 - High Voltage Differential Probe.
|