Tektronix TDS210 * TDS220 * TDS224 Digital Storage Oscilloscopes

Characteristics

Signal Acquisition System

Bandwidth -
TDS210: 60 MHz.
TDS220: 100 MHz.
TDS224: 100 MHz.

Sample Rate -
1 GS/s on each channel.

Channels -
TDS210 and TDS220: 2 identical channels plus external trigger.
TDS224: 4 identical channels.

Sensitivity (with calibrated fine adjustment) -
2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode).

Vertical Zoom -
Vertically expand or compress a live or stopped waveform.

Calibrated Position Range

Volts/Div Setting

Offset Range

2 mV to 200 mV/div ±2 V
>200 mV to 5 V/div ±50 V

DC Gain Accuracy - ±3%. (±4% at 2 mV/div and 5 mV/div).

Vertical Resolution -
8-Bits (256 levels over 10.24 vertical divisions).

Automatic Measurements

Period, Frequency, Cycle RMS, Mean, Peak to Peak.

Acquisition Modes

Sample, Average, Peak Detect - High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 µs/div and 5 s/div.

Time Base System (Main and Window)

Horizontal Zoom - Horizontally expand or compress a live or stopped waveform.

Time/Division Range - 5 ns to 5 s/div.

Record Length - 2500 sample points per channel.

Horizontal Accuracy - ±0.01%.

Nonvolatile Storage

Waveform Display - Two 2500 point reference waveforms.

Waveform Storage - Two 2500 point reference waveforms (TDS210, TDS220), four 2500 point reference waveforms (TDS224).

Setups - 5 front panel setups.

Triggering System (Main Only)

Trigger Type - Edge (Rising or Falling), Video, Set to 50%.

Video Trigger Type - Triggers on Fields or Lines from composite video; triggers on broadcast standard NTSC, PAL or SECAM video.

Trigger Modes - Auto, Normal, Single Sweep.

Trigger Source -
TDS210 and TDS220: CH1, CH2, Ext, Ext/5 and AC Line.
TDS224: CH1, CH2, CH3, Ch3 and AC Line.

Trigger View - Displays trigger signal while trigger view button depressed.

Cursors

Types - Voltage, Time.

Measurements - [DELTA]T, 1/[DELTA]T, [DELTA]V.

Waveform Processing

Arithmetic Operators - Add, Subtract.

Sources - CH1±CH2, CH3±Ch3 (TDS224).

Autoset - Single button automatic setup on selected input signal for vertical, horizontal and trigger systems.

Display System

Robust, backlit LCD with adjustable multilevel contrast.

Interpolation - Sin(x)/x.

Display Modes - Vectors, dots.

Persistence - Off, 1 sec, 2 sec, 5 sec, Infinite.

Format - YT and XY.

Hardcopy Capability (Requires Modules)

Printer/File Formats - Thinkjet, Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412.

Hardcopy Layout - Landscape or Portrait.

TDS2CM Communications Extension Module

Centronics-type Parallel Port

RS-232 Programmability - Full talk/listen modes. Control of all modes, settings and measurements. Baud Rate up to 19,200. 9-Pin, DTE.

GPIB Programmability - Full talk/listen modes. Control of all modes, settings and measurements (IEEE Std 488-1987).
Includes WaveStarTM Software for Oscilloscopes 30 day product demo.

TDS2MM Measurement Extension Module

FFT - Windows: Hanning, Flat Top, Rectangular.
Sample points: 2048.

Automatic Measurements - Rise/Fall Time, Positive/Negative Pulse Width.

Interface - Centronics, RS-232, GPIB.

Environmental and Safety

Temperature -
Operating: 0°C to +50°C.
Nonoperating: -20°C to +60°C.

Humidity -
Up to 90% RH at or below +40°C;
Up to 60% RH from 41°C to 50°C (Operating and Nonoperating).

Altitude -
Up to 3000 m (Operating).

EMC -
Meets Directive 89/336/EEC.

Safety - UL3111-1, CSA1010.1, IEC61010-1, EN61010-1.

Physical Characteristics

Dimensions mm in.
Width 304.8 12.0
Height 151.4 5.96
Depth 120.7 4.75
Weight kg lb.
oscilloscope only 1.5 3.25
w/accessories 1.7 3.75



 
 