Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
Electronic Test Equipment - MetricTest   Advanced
1.800.417.4370
 
 

TEK TDS680C Digital Storage Oscilloscopes

Features

  • 3 GHz, 1 GHz and 500 MHz Bandwidths to Work with the Fastest Signals in Today's Digital Designs
  • 10 GS/s and 5 GS/s Sample Rates on all Channels Simultaneously for Full Bandwidth Single-shot Capture
  • Histograms and Measurement Statistics to More Fully Characterize Design Performance
  • Support for Java Applications Packages
  • Hard Disk Drive Storage (option)
  • Support for Iomega parallel port ZipTM drives
  • Waveform Math and Advanced Waveform DSP
  • Fully Automated Measurement System
  • Waveform Pass/Fail Template Testing
  • Color Display (TDS 654C, TDS 684C, TDS 694C)
  • RS-232, Centronics, and GPIB Interfaces Included Standard
  • Record Length to 120,000 Points/channel*
  • Timebase Accuracy to 10 ppm, Time Interval Measurement Accuracy to ± 15 ps (TDS 694C)
  • Trigger Jitter 8 ps RMS (Typical)
  • 1% Vertical Accuracy (TDS 694C)
  • 100 ps Peak Detect (TDS 694C only)

* TDS 694C with long record length option (1 M) only. 15,000 points/channel maximum on TDS 684C/680C/654C.

Whether you are working on next generation microprocessor designs, high-speed data communications equipment, or in high-energy physics research, the TDS 694C captures your fastest signals with the best fidelity and resolution available. Its 3 GHz bandwidth preserves your waveform's fast rising edges and accurately shows signal details. With 10 GS/s digitizing rate simultaneously on all four channels and a high-stability timebase, the TDS 694C makes your critical timing measurements with the highest resolution and accuracy - even channel-to-channel measurements made in a single acquisition.

The TDS 600C oscilloscopes incorporate all the advanced trigger features you expect in a high performance oscilloscope: triggering on Glitches, Slew Rate violations, Setup and Hold Time violations, Time Outs, Logic Patterns and States on four channels. For applications where sophisticated multi-channel debugging is required, the TDS 694C can be configured for cross triggering with a Tektronix TLA 700 Logic Analyzer.

The TDS 600C oscilloscopes give you the total solution to your digital design characterization and debugging needs. Now you have the tool you need to verify design margins, characterize setup and hold times, and measure clock-to-data skew on the fastest digital designs. The TDS 694C's companion probe, the P6249, offers small size to reliably contact your high-density boards with their fine-pitch, hard to reach components. The P6249 has short ground connection to give the maximum system bandwidth and preserve the details of your signals.

The TDS 600C offers 29 automatic measurements, with measurement statistics, to make your design verification and characterization job much faster and easier. Available Java-based application packages for Jitter Analysis, Disk Drive measurements and Processor Specification measurements provide customized measurements and analysis capability. The TDS 600C gives you the performance and features you need to get your job done faster and more thoroughly.

Applications
  • Validation and Characterization of High Speed Digital Designs
    • Verify Simulation Performance with Real Measurements
    • Ensure that Desired Design Margins Exist
    • Jitter Measurements on High-speed Data, Phase-locked Loops and Spread-spectrum Clock Circuits
    • Capture Glitches, Cross-talk, Setup/hold Violations
  • Telecommunications/Data Communications Design
    • Characterize Rise Times, Overshoot, Channel to Channel Timing
    • Verify and Test High Speed Serial Data Streams
  • High Energy Physics
    • Transient Event Capture

Specifications


TDS 654C

TDS 680C

TDS 684C

TDS 694C

Total Channels

4

2 + 2

4

4

Sample Rate (all channels simultaneously)

5 GS/s

5 GS/s

5 GS/s

10 GS/s

Real-time Bandwidth

500 MHz

1 GHz

1 GHz

3 GHz

Maximum Record Length per Channel

15,000 pts

15,000 pts

15,000 pts

120,000 pts

Vertical Resolution

1 mV/div - 10 V/div

1 mV/div - 10 V/div

1 mV/div - 10 V/div

10 mV/div - 1 V/div

Delta Time Measurement Accuracy

< 50 ps @ 5 GS/s

< 50 ps @ 5 GS/s

< 50 ps @ 5 GS/s

15 ps @ 10 GS/s

Advanced Waveform DSP/Math

Std.

Std.

Std.

Std.

Histograms and Measurement Statistics

Std.

Std.

Std.

Std.

Standard Probes

4 P6243

None

None

None

Display Type

7 in. NuColorTM Display

7 in. monochrome

7 in. NuColorTM Display

7 in. NuColorTM Display

Floppy Drive

Std.

Std.

Std.

Std.

GPIB, RS-232 & Centronics

Std.

Std.

Std.

Std.

VGA Output

Std. Color

Std. Mono

Std. Color

Std. Color

Hard Disk Drive

Opt.

Opt.

Opt.

Opt.

Triggering System Trigger Types

EDGE (Main and Delayed) -
Conventional level-driven trigger. Positive or negative slope on any channel or rear panel auxiliary input. Coupling selections: DC, AC, noise reject, HF reject, LF reject.

LOGIC (Main) -
PATTERN: Specifies a logical combination (AND, OR, NAND, NOR) of the four input channels (high, low, don't care). Trigger when pattern stays true or false for a specified time.
STATE: Any logical pattern of channels 1, 2, and 3 (AUX1 on TDS680C) plus a clock edge on channel 4 (AUX2 on TDS680C). Triggerable on rising or falling clock edge.
SETUP/HOLD: Trigger on violations of both setup time and hold time between clock and data which are on two input channels.

PULSE (Main) -
GLITCH: Trigger on or reject glitches of positive, negative, or either polarity. Minimum glitch width is 1.0 ns with 200 ps resolution.
RUNT: Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
WIDTH: Trigger on width of positive or negative pulse either within or out of selectable time limits (1 ns to 1 s).
SLEW RATE: Trigger on pulse edge rates that are either faster or slower than a set rate. Edges can be rising, falling, or either.
TIMEOUT: Trigger on an event which remains high, low, or either, for a specified time period, selectable from 1 ns to 1 s, with 200 ps resolution.

TLA Cross Trigger (TDS 694C only) - Utilize a TLA 700 logic analyzer to detect a multi-channel event, then trigger the TDS 694C. The trigger points on the TLA and TDS will be aligned in time.

VIDEO (Optional; Not Available in TDS 694C) -
Trigger on a particular line of individual, odd/even, or all fields. Trigger on a specific pixel of a line by using the video trigger with delay by events. Choose positive or negative horizontal sync polarity.
525/NTSC: Choose monochrome or color (studio-quality NTSC) sync formats. 625/PAL: Choose color or monochrome (studio-quality PAL) sync formats. HDTV: Choose from 1125/60, 1050/60, 1250/50, and 787.5/60 HDTV formats.

Trigger Bandwidth (Edge Type) -
3 GHz (TDS 694C).
1 GHz (TDS 684C, TDS 680C).
500 MHz (TDS 654C).

Main Trigger Modes - Auto, Normal, Single.

Delayed Trigger - Delay by time, events, or events and time.

Delay by Time Range - 16 ns to 250 s.

Delay by Events Range - 2 to 9,999,999 events.

External Trigger Input - Input Impedance: >1.5 kilohm; Max. Input Voltage: ±20 V (DC + peak AC).

Display Characteristics

Waveform Style - Dots, vectors, variable persistence from 32 ms to 10 s, infinite persistence, and intensified samples.

Color (TDS 694C, TDS 684C, TDS 654C) - Standard palettes and user-definable color for waveforms, text, graticules, and cursors. Measurement text and cursor colors matched to waveform. Waveform collision areas highlighted with different color. Statistical waveform distribution shown with color grading through variable persistence.

Color Grading (TDS 694C, TDS 684C, TDS 654C) - With variable persistence selected, historical timing information is represented by temperature or spectral color scheme (or gray scale on TDS 680C).

Graticules - Full, grid, cross-hair, frame, and NTSC and PAL (with video trigger option).

Format - YT and XY.

Resolution - 640 horizontal by 480 vertical displayed pixels (VGA).

Color CRT Monitor (TDS 654C/684C/694C) - 7 in. diagonal NuColorTM liquid crystal full-color shutter, 256 levels.

Monochrome CRT Monitor (TDS 680C) - 7 in. diagonal, magnetic deflection. Horizontal raster-scan. P4 white phosphor.

Measurement System

Automatic Waveform Measurements -
Period, frequency, + width, - width, rise time, fall time, + duty cycle, - duty cycle, delay, phase, burst width, high, low, max, min, peak to peak, amplitude, + overshoot, - overshoot, mean, cycle mean, RMS, cycle RMS, area, cycle area, extinction ratio (ratio, dB, %), and mean optical power. Continuous update of up to four measurements on any combination of waveforms.

Measurement Statistics - Display minimum and maximum or mean and standard deviation on any displayed single-waveform measurements.

Thresholds - Settable in percentage or voltage.

Gating - Any region of the waveform may be isolated for measurement using vertical bars.

Snapshot - Performs all measurements on any one waveform showing results from one instant in time.

Cursor Measurements - Absolute, Delta: Volts, Time, Frequency, and NTSC IRE and line number (with video trigger option).

Cursor Types - Horizontal bars (volts), vertical bars (time); operated independently or in tracking mode.

Histogram Measurements - Mean, median, standard deviation, hits, waveform count, peak hits, peak to peak, % mean ± 1, 2, and 3 standard deviations.

Waveform Processing

Waveform Functions - Interpolation (sin(x)/x or linear), Average, Envelope, Auto Setup.

Advanced Waveform Functions - FFT, Integration, Differentiation, Waveform (math or acquired) Limit Testing.

Arithmetic Operators - Add, Subtract, Multiply, Divide, Invert.

Autoset - Single-button, automatic setup on selected input signal for vertical, horizontal, and trigger systems.

Waveform Limit Testing - Compares incoming or math waveform to a reference waveform's upper and lower limits.

Waveform Histograms - Both vertical and horizontal histograms, with periodically updated measurements, allow statistical distributions to be analyzed over any region of the signal.

Zoom Characteristics

The zoom feature allows waveforms to be expanded or compressed in both vertical and horizontal axes. Allows precise comparison and study of fine waveform detail without affecting ongoing acquisitions. When used with Average acquisition modes, Zoom provides an effective vertical dynamic range of 1000 divisions or 100 screens.

Dual Window Zoom - Dual graticules simultaneously show selected and zoomed waveforms. Up to two zoom boxes show areas on the selected trace that are being magnified, and the two magnified areas can be overlapped for quick comparison. Color of zoomed trace matches selected trace.

Computer Interface

GPIB (IEEE-488.2) Programmability - Full talk/listen modes. Control of all modes, settings, and measurements.

Hardcopy

Printer - HP Thinkjet, Deskjet, Laserjet, Epson, Interleaf, PostScript, TIFF, PCX, BMP, DPU411/412, RLE.

Plotter - HPGL.

Data - MathCad, spreadsheet formats.

Hardcopy Interface - Centronics and RS-232 (talk only).

Data Storage

Standard - Internal MS-DOS 1.44 Mbyte floppy, external Iomega ZipTM drive support.

Optional - Internal hard disk drive.

Non-volatile Storage for Setups - 10 front panel setups.

Floppy Disk Drive - Store reference waveforms, setups, and image files on 3.5 in. 1.44 MB or 720 K DOS-format floppy disk.

Iomega ZipTM Drive Compatible - Compatible for waveform, hardcopy, and front panel setup file transfer to Iomega ZipTM, ZipPlusTM, and Zip250TM Drive.

Power Requirements

Line Voltage Range - 90 to 250 V RMS.

Line Frequency - 45 to 440 Hz.

Power Consumption -
300 W max. (TDS 654C/680C/684C).
450 W max. (TDS 694C).

Environmental and Safety

Temperature -
Operating: +4° C to +45° C (floppy not used), +10° C to +45° C (floppy in use). Non-operating: -22° C to +60° C.
TDS 694C: Operating: +5°C to +40°C (floppy not used), +10°C to +40°C (floppy in use). Non-operating: -22°C to +60°C.

Humidity -
Operating: 20% to 80% RH at or below +32°C.

Altitude -
Operating: 15,000 ft. (hard disk not used), 10,000 ft. (hard disk in use). Non-operating: 40,000 ft.

Electromagnetic Compatibility - UL1244.

Safety - UL 3111-1, CSA1010.1, EN61010-1, IEC61010-1.

Physical Characteristics

Dimensions

mm

in.

Height with feet

193

7.6

Height without feet

178

7

Width with handle

445

17.5

Depth with front cover installed

434

17.1

Weight

kg

lbs.

Net approximately

14.1

31

Shipping Weight approximately

 24.0 

53

Specs

Ordering Information

TEK TDS680C Digital Storage Oscilloscopes

TDS 684C
Four-channel Color 1 GHz, 5 GS/s Per Channel Digital Storage Oscilloscope.

Includes: User Manual (070-0130-00), User Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference Manual (071-0272-00).

TDS 680C
Two-channel Monochrome 1 GHz, 5 GS/s Per Channel Digital Storage Oscilloscope.

Includes: User Manual (070-0130-00), User Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference Manual (071-0272-00).

TDS 654C
Four-channel Color 500 MHz, 5 GS/s Per Channel Digital Storage Oscilloscope. Includes: Four P6243 FET Probes.

Includes: User Manual (070-0130-00), User Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference Manual (071-0272-00).

TDS 654C/TDS 680C/TDS 684C Include: User Manual (070-0130-00), User Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer’s Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference Manual (071-0272-00), Front Cover (200-3696-00)
North American Power Cord (161-0230-01)
Accessory Pouch (016-1268-00) (Except TDS 680C).

Options

Opt. 05 - Video Trigger, NTSC, PAL, HDTV, FlexFormatTM. (Except TDS 694C)

Opt. 1K - Model K420 Instrument Cart.

Opt. 1M - 120 k Record Length. (TDS 694C only)

Opt. 1R - Rackmount Kit.

Opt. 31 - Add 1 ea. P6339A Buffered Passive Probe. (TDS 694C only)

Opt. 33 - Add 1 ea. P6158 Low Capacitance Probe. (Except TDS 654C)

Opt. 34 - Add 1 ea. P6247 Differential Probe. (Except TDS 694C)

Opt. 35 - Add 1 ea. P6243 Active Probe. (TDS 654C Only)

Opt. 36 - Add 1 ea. P6139A Passive Probe. (Except TDS 694C)

Opt. 37 - Add 1 ea. P6245 Active Probe. (Except TDS 654C)

Opt. 38 - Add 1 ea. P6249 4 GHz Active Probe. (TDS 694C only)

Opt. 39 - Add 1 ea. P6248 1.7 GHz Differential Probe. (TDS 694C only)

Opt. HD - Internal Hard Disk Drive.

International Power Plugs

Opt. A1 - Universal Euro 220 V, 50 Hz.

Opt. A2 - UK 240 V, 50 Hz.

Opt. A3 - Australian 240 V, 50 Hz.

Opt. A5 - Switzerland 220 V, 50 Hz.

See General Customer Information for additional description.

Measurement Service Options

Opt. C3 - Three years of Calibration Services.

Opt. D1 - Calibration Data Report.

Opt. D3 - Test Data (requires Opt. C3).

See General Customer Information for further information.

Software

TDS Java Applications

TDSJIT1 - Jitter and timing analysis application.

TDSDDM1 - Hard disk drive measurement application.

TDSPSM1 - Processor specifications measurement application.

TDSPRT1 - Enhanced waveform printing application.

WSTRO - WaveStarTM software for Oscilloscopes, Windows 95/NT application for waveform capture, analysis, documentation and control from your PC.

WSTROU - Upgrade from WSTR31 to WSTRO.

WSTR31 - WavesStarTM software for Windows 3.1.

WSTR31U - Upgrade fom DocuWaveTM software to WSTR31.

LVWIN95 - LabVIEW® for Windows 95.

LVWCVI95 - LabWindows/CVI for Windows 95.

Recommended Accessories

See Accessories.

P6249 - 4 GHz Active Probe.

P6248 - 1.7 GHz Differential Probe.

WSTRO - WaveStarTM software for Oscilloscopes, Windows 95/NT application for waveform capture, analysis, documentation and control from your PC.

SureFoot - Surface Mount Device Interconnects.

 

 


 
 
  Company    |   Contact Us   |   Site Map 1.800.417.4370
 
 
 
 
Copyright©2008 MetricTest. All rights reserved. Privacy & Security