Features
- 3 GHz, 1 GHz and 500 MHz Bandwidths to Work with the Fastest Signals
in Today's Digital Designs
- 10 GS/s and 5 GS/s Sample Rates on all Channels Simultaneously for
Full Bandwidth Single-shot Capture
- Histograms and Measurement Statistics to More Fully Characterize
Design Performance
- Support for Java Applications Packages
- Hard Disk Drive Storage (option)
- Support for Iomega parallel port ZipTM drives
- Waveform Math and Advanced Waveform DSP
- Fully Automated Measurement System
- Waveform Pass/Fail Template Testing
- Color Display (TDS 654C, TDS 684C, TDS 694C)
- RS-232, Centronics, and GPIB Interfaces Included Standard
- Record Length to 120,000 Points/channel*
- Timebase Accuracy to 10 ppm, Time Interval Measurement Accuracy
to ± 15 ps (TDS 694C)
- Trigger Jitter 8 ps RMS (Typical)
- 1% Vertical Accuracy (TDS 694C)
- 100 ps Peak Detect (TDS 694C only)
Whether you are working on next generation microprocessor
designs, high-speed data communications equipment, or in high-energy physics
research, the TDS 694C captures your fastest signals with the best fidelity
and resolution available. Its 3 GHz bandwidth preserves your waveform's
fast rising edges and accurately shows signal details. With 10 GS/s
digitizing rate simultaneously on all four channels and a high-stability
timebase, the TDS 694C makes your critical timing measurements with the
highest resolution and accuracy - even channel-to-channel measurements
made in a single acquisition.
The TDS 600C oscilloscopes incorporate all the advanced
trigger features you expect in a high performance oscilloscope: triggering
on Glitches, Slew Rate violations, Setup and Hold Time violations, Time
Outs, Logic Patterns and States on four channels. For applications where
sophisticated multi-channel debugging is required, the TDS 694C
can be configured for cross triggering with a Tektronix TLA 700 Logic
Analyzer.
The TDS 600C oscilloscopes give you the total solution to
your digital design characterization and debugging needs. Now you have
the tool you need to verify design margins, characterize setup and hold
times, and measure clock-to-data skew on the fastest digital designs.
The TDS 694C's companion probe, the P6249, offers small size
to reliably contact your high-density boards with their fine-pitch, hard
to reach components. The P6249 has short ground connection to give the
maximum system bandwidth and preserve the details of your signals.
The TDS 600C offers 29 automatic measurements, with measurement
statistics, to make your design verification and characterization job
much faster and easier. Available Java-based application packages for
Jitter Analysis, Disk Drive measurements and Processor Specification measurements
provide customized measurements and analysis capability. The TDS 600C
gives you the performance and features you need to get your job done faster
and more thoroughly.
Applications
- Validation and Characterization of High Speed Digital Designs
- Verify Simulation Performance with Real Measurements
- Ensure that Desired Design Margins Exist
- Jitter Measurements on High-speed Data, Phase-locked Loops and
Spread-spectrum Clock Circuits
- Capture Glitches, Cross-talk, Setup/hold Violations
- Telecommunications/Data Communications Design
- Characterize Rise Times, Overshoot, Channel to Channel Timing
- Verify and Test High Speed Serial Data Streams
- High Energy Physics
Specifications
|
|
TDS 654C
|
TDS 680C
|
TDS 684C
|
TDS 694C
|
|
Total Channels
|
4
|
2 + 2
|
4
|
4
|
|
Sample Rate (all channels simultaneously)
|
5 GS/s
|
5 GS/s
|
5 GS/s
|
10 GS/s
|
|
Real-time Bandwidth
|
500 MHz
|
1 GHz
|
1 GHz
|
3 GHz
|
|
Maximum Record Length per Channel
|
15,000 pts
|
15,000 pts
|
15,000 pts
|
120,000 pts
|
|
Vertical Resolution
|
1 mV/div - 10 V/div
|
1 mV/div - 10 V/div
|
1 mV/div - 10 V/div
|
10 mV/div - 1 V/div
|
|
Delta Time Measurement Accuracy
|
<
50 ps @ 5 GS/s
|
<
50 ps @ 5 GS/s
|
<
50 ps @ 5 GS/s
|
15 ps @ 10 GS/s
|
|
Advanced Waveform DSP/Math
|
Std.
|
Std.
|
Std.
|
Std.
|
|
Histograms and Measurement Statistics
|
Std.
|
Std.
|
Std.
|
Std.
|
|
Standard Probes
|
4 P6243
|
None
|
None
|
None
|
|
Display Type
|
7 in. NuColorTM Display
|
7 in. monochrome
|
7 in. NuColorTM Display
|
7 in. NuColorTM Display
|
|
Floppy Drive
|
Std.
|
Std.
|
Std.
|
Std.
|
|
GPIB, RS-232 & Centronics
|
Std.
|
Std.
|
Std.
|
Std.
|
|
VGA Output
|
Std. Color
|
Std. Mono
|
Std. Color
|
Std. Color
|
|
Hard Disk Drive
|
Opt.
|
Opt.
|
Opt.
|
Opt.
|
Triggering System Trigger Types
EDGE (Main and Delayed) -
Conventional level-driven trigger. Positive or negative slope on any channel
or rear panel auxiliary input. Coupling selections: DC, AC, noise reject,
HF reject, LF reject.
LOGIC (Main) -
PATTERN: Specifies a logical combination (AND, OR, NAND, NOR) of the four
input channels (high, low, don't care). Trigger when pattern stays true
or false for a specified time.
STATE: Any logical pattern of channels 1, 2, and 3 (AUX1 on TDS680C) plus
a clock edge on channel 4 (AUX2 on TDS680C). Triggerable on rising or
falling clock edge.
SETUP/HOLD: Trigger on violations of both setup time and hold time between
clock and data which are on two input channels.
PULSE (Main) -
GLITCH: Trigger on or reject glitches of positive, negative, or either
polarity. Minimum glitch width is 1.0 ns with 200 ps resolution.
RUNT: Trigger on a pulse that crosses one threshold but fails to cross
a second threshold before crossing the first again.
WIDTH: Trigger on width of positive or negative pulse either within or
out of selectable time limits (1 ns to 1 s).
SLEW RATE: Trigger on pulse edge rates that are either faster or slower
than a set rate. Edges can be rising, falling, or either.
TIMEOUT: Trigger on an event which remains high, low, or either, for a
specified time period, selectable from 1 ns to 1 s, with 200 ps
resolution.
TLA Cross Trigger (TDS 694C only)
- Utilize a TLA 700 logic analyzer to detect a multi-channel event, then
trigger the TDS 694C. The trigger points on the TLA and TDS will be aligned
in time.
VIDEO (Optional; Not Available in
TDS 694C) -
Trigger on a particular line of individual, odd/even, or all fields. Trigger
on a specific pixel of a line by using the video trigger with delay by
events. Choose positive or negative horizontal sync polarity.
525/NTSC: Choose monochrome or color (studio-quality NTSC) sync formats.
625/PAL: Choose color or monochrome (studio-quality PAL) sync formats.
HDTV: Choose from 1125/60, 1050/60, 1250/50, and 787.5/60 HDTV formats.
Trigger Bandwidth (Edge Type) -
3 GHz (TDS 694C).
1 GHz (TDS 684C, TDS 680C).
500 MHz (TDS 654C).
Main Trigger Modes - Auto, Normal,
Single.
Delayed Trigger - Delay by time,
events, or events and time.
Delay by Time Range - 16 ns
to 250 s.
Delay by Events Range - 2 to 9,999,999
events.
External Trigger Input - Input Impedance:
>1.5 kilohm; Max. Input Voltage: ±20 V (DC
+ peak AC).
Display Characteristics
Waveform Style - Dots, vectors,
variable persistence from 32 ms to 10 s, infinite persistence, and intensified
samples.
Color (TDS 694C, TDS 684C, TDS 654C)
- Standard palettes and user-definable color for waveforms, text, graticules,
and cursors. Measurement text and cursor colors matched to waveform. Waveform
collision areas highlighted with different color. Statistical waveform
distribution shown with color grading through variable persistence.
Color Grading (TDS 694C, TDS 684C,
TDS 654C) - With variable persistence selected, historical timing information
is represented by temperature or spectral color scheme (or gray scale
on TDS 680C).
Graticules - Full, grid, cross-hair,
frame, and NTSC and PAL (with video trigger option).
Format - YT and XY.
Resolution - 640 horizontal by 480
vertical displayed pixels (VGA).
Color CRT Monitor (TDS 654C/684C/694C)
- 7 in. diagonal NuColorTM liquid crystal full-color shutter,
256 levels.
Monochrome CRT Monitor (TDS 680C)
- 7 in. diagonal, magnetic deflection. Horizontal raster-scan. P4 white
phosphor.
Measurement System
Automatic Waveform Measurements
-
Period, frequency, + width, - width, rise time, fall time, + duty cycle,
- duty cycle, delay, phase, burst width, high, low, max, min, peak to
peak, amplitude, + overshoot, - overshoot, mean, cycle mean, RMS, cycle
RMS, area, cycle area, extinction ratio (ratio, dB, %), and mean
optical power. Continuous update of up to four measurements on any combination
of waveforms.
Measurement Statistics - Display
minimum and maximum or mean and standard deviation on any displayed single-waveform
measurements.
Thresholds - Settable in percentage
or voltage.
Gating - Any region of the waveform
may be isolated for measurement using vertical bars.
Snapshot - Performs all measurements
on any one waveform showing results from one instant in time.
Cursor Measurements - Absolute,
Delta: Volts, Time, Frequency, and NTSC IRE and line number (with
video trigger option).
Cursor Types - Horizontal bars (volts),
vertical bars (time); operated independently or in tracking mode.
Histogram Measurements - Mean, median,
standard deviation, hits, waveform count, peak hits, peak to peak, % mean
± 1, 2, and 3 standard deviations.
Waveform Processing
Waveform Functions - Interpolation
(sin(x)/x or linear), Average, Envelope, Auto Setup.
Advanced Waveform Functions - FFT,
Integration, Differentiation, Waveform (math or acquired) Limit Testing.
Arithmetic Operators - Add, Subtract,
Multiply, Divide, Invert.
Autoset - Single-button, automatic
setup on selected input signal for vertical, horizontal, and trigger systems.
Waveform Limit Testing - Compares
incoming or math waveform to a reference waveform's upper and lower limits.
Waveform Histograms - Both vertical
and horizontal histograms, with periodically updated measurements, allow
statistical distributions to be analyzed over any region of the signal.
Zoom Characteristics
The zoom feature allows waveforms
to be expanded or compressed in both vertical and horizontal axes. Allows
precise comparison and study of fine waveform detail without affecting
ongoing acquisitions. When used with Average acquisition modes, Zoom provides
an effective vertical dynamic range of 1000 divisions or 100 screens.
Dual Window Zoom - Dual graticules
simultaneously show selected and zoomed waveforms. Up to two zoom boxes
show areas on the selected trace that are being magnified, and the two
magnified areas can be overlapped for quick comparison. Color of zoomed
trace matches selected trace.
Computer Interface
GPIB (IEEE-488.2) Programmability
- Full talk/listen modes. Control of all modes, settings, and measurements.
Hardcopy
Printer - HP Thinkjet, Deskjet,
Laserjet, Epson, Interleaf, PostScript, TIFF, PCX, BMP, DPU411/412, RLE.
Plotter - HPGL.
Data - MathCad, spreadsheet formats.
Hardcopy Interface - Centronics
and RS-232 (talk only).
Data Storage
Standard - Internal MS-DOS 1.44
Mbyte floppy, external Iomega ZipTM drive support.
Optional - Internal hard disk drive.
Non-volatile Storage for Setups
- 10 front panel setups.
Floppy Disk Drive - Store reference
waveforms, setups, and image files on 3.5 in. 1.44 MB or 720 K DOS-format
floppy disk.
Iomega ZipTM Drive Compatible
- Compatible for waveform, hardcopy, and front panel setup file transfer
to Iomega ZipTM, ZipPlusTM, and Zip250TM
Drive.
Power Requirements
Line Voltage Range - 90 to
250 V RMS.
Line Frequency - 45 to 440 Hz.
Power Consumption -
300 W max. (TDS 654C/680C/684C).
450 W max. (TDS 694C).
Environmental and Safety
Temperature -
Operating: +4° C to +45° C (floppy not used), +10° C to +45°
C (floppy in use). Non-operating: -22° C to +60° C.
TDS 694C: Operating: +5°C to +40°C (floppy not used), +10°C
to +40°C (floppy in use). Non-operating: -22°C to +60°C.
Humidity -
Operating: 20% to 80% RH at or below +32°C.
Altitude -
Operating: 15,000 ft. (hard disk not used), 10,000 ft. (hard disk in use).
Non-operating: 40,000 ft.
Electromagnetic Compatibility -
UL1244.
Safety - UL 3111-1, CSA1010.1, EN61010-1,
IEC61010-1.
Physical Characteristics
|
Dimensions
|
mm
|
in.
|
|
Height with feet
|
193
|
7.6
|
|
Height without feet
|
178
|
7
|
|
Width with handle
|
445
|
17.5
|
|
Depth with front cover installed
|
434
|
17.1
|
|
Weight
|
kg
|
lbs.
|
|
Net approximately
|
14.1
|
31
|
|
Shipping Weight approximately
|
24.0
|
53
|
Specs
Ordering Information
TDS 684C
Four-channel Color 1 GHz, 5 GS/s Per
Channel Digital Storage Oscilloscope.
Includes: User Manual (070-0130-00), User
Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's
Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference
Manual (071-0272-00).
TDS 680C
Two-channel Monochrome 1 GHz, 5 GS/s
Per Channel Digital Storage Oscilloscope.
Includes: User Manual (070-0130-00), User
Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's
Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference
Manual (071-0272-00).
TDS 654C
Four-channel Color 500 MHz, 5 GS/s
Per Channel Digital Storage Oscilloscope. Includes: Four P6243 FET Probes.
Includes: User Manual (070-0130-00), User
Supplement (071-0273-00), Quick Reference Guide (020-2235-00), Programmer's
Manual in MS-Help format on floppy disk (063-3120-00), Technical Reference
Manual (071-0272-00).
TDS 654C/TDS 680C/TDS 684C Include: User
Manual (070-0130-00), User Supplement (071-0273-00), Quick Reference Guide
(020-2235-00), Programmer’s Manual in MS-Help format on floppy disk (063-3120-00),
Technical Reference Manual (071-0272-00), Front Cover (200-3696-00)
North American Power Cord (161-0230-01)
Accessory Pouch (016-1268-00) (Except TDS 680C).
Options
Opt. 05 - Video Trigger, NTSC, PAL, HDTV,
FlexFormatTM. (Except TDS 694C)
Opt. 1K - Model K420 Instrument Cart.
Opt. 1M - 120 k Record Length. (TDS 694C
only)
Opt. 1R - Rackmount Kit.
Opt. 31 - Add 1 ea. P6339A Buffered Passive
Probe. (TDS 694C only)
Opt. 33 - Add 1 ea. P6158 Low Capacitance
Probe. (Except TDS 654C)
Opt. 34 - Add 1 ea. P6247 Differential Probe.
(Except TDS 694C)
Opt. 35 - Add 1 ea. P6243 Active Probe. (TDS
654C Only)
Opt. 36 - Add 1 ea. P6139A Passive Probe.
(Except TDS 694C)
Opt. 37 - Add 1 ea. P6245 Active Probe. (Except
TDS 654C)
Opt. 38 - Add 1 ea. P6249 4 GHz Active Probe.
(TDS 694C only)
Opt. 39 - Add 1 ea. P6248 1.7 GHz Differential
Probe. (TDS 694C only)
Opt. HD - Internal Hard Disk Drive.
International Power Plugs
Opt. A1 - Universal Euro 220 V, 50 Hz.
Opt. A2 - UK 240 V, 50 Hz.
Opt. A3 - Australian 240 V, 50 Hz.
Opt. A5 - Switzerland 220 V, 50 Hz.
Measurement Service Options
Opt. C3 - Three years of Calibration Services.
Opt. D1 - Calibration Data Report.
Opt. D3 - Test Data (requires Opt. C3).
Software
TDS Java Applications
TDSJIT1 - Jitter and timing analysis application.
TDSDDM1 - Hard disk drive measurement application.
TDSPSM1 - Processor specifications measurement
application.
TDSPRT1 - Enhanced waveform printing application.
WSTRO - WaveStarTM software for
Oscilloscopes, Windows 95/NT application for waveform capture, analysis,
documentation and control from your PC.
WSTROU - Upgrade from WSTR31 to WSTRO.
WSTR31 - WavesStarTM software
for Windows 3.1.
WSTR31U - Upgrade fom DocuWaveTM
software to WSTR31.
LVWIN95 - LabVIEW® for Windows 95.
LVWCVI95 - LabWindows/CVI for Windows 95.
Recommended Accessories
See Accessories.
P6249 - 4 GHz Active Probe.
P6248 - 1.7 GHz Differential Probe.
WSTRO - WaveStarTM software for
Oscilloscopes, Windows 95/NT application for waveform capture, analysis,
documentation and control from your PC.
SureFoot - Surface Mount Device Interconnects.
|