TEK TDS694C Digital Storage Oscilloscope
Features
Whether you are working on next generation microprocessor designs, high-speed
data communications equipment, or in high-energy physics research, the
TDS 694C captures your fastest signals with the best fidelity and resolution
available. Its 3 GHz bandwidth preserves your waveform's fast rising
edges and accurately shows signal details. With 10 GS/s digitizing
rate simultaneously on all four channels and a high-stability timebase,
the TDS 694C makes your critical timing measurements with the highest
resolution and accuracy - even channel-to-channel measurements made in
a single acquisition.
The TDS 600C oscilloscopes incorporate all the advanced trigger features
you expect in a high performance oscilloscope: triggering on Glitches,
Slew Rate violations, Setup and Hold Time violations, Time Outs, Logic
Patterns and States on four channels. For applications where sophisticated
multi-channel debugging is required, the TDS 694C can be configured
for cross triggering with a Tektronix TLA 700 Logic Analyzer.
The TDS 600C oscilloscopes give you the total solution to your digital
design characterization and debugging needs. Now you have the tool you
need to verify design margins, characterize setup and hold times, and
measure clock-to-data skew on the fastest digital designs. The TDS 694C's
companion probe, the P6249, offers small size to reliably contact your
high-density boards with their fine-pitch, hard to reach components. The
P6249 has short ground connection to give the maximum system bandwidth
and preserve the details of your signals.
The TDS 600C offers 29 automatic measurements, with measurement statistics,
to make your design verification and characterization job much faster
and easier. Available Java-based application packages for Jitter Analysis,
Disk Drive measurements and Processor Specification measurements provide
customized measurements and analysis capability. The TDS 600C gives you
the performance and features you need to get your job done faster and
more thoroughly.
- 3 GHz, 1 GHz and 500 MHz Bandwidths to Work with the Fastest Signals
in Today's Digital Designs
- 10 GS/s and 5 GS/s Sample Rates on all Channels Simultaneously for
Full Bandwidth Single-shot Capture
- Histograms and Measurement Statistics to More Fully Characterize Design
Performance
- Support for Java Applications Packages
- Hard Disk Drive Storage (option)
- Support for Iomega parallel port ZipTM drives
- Waveform Math and Advanced Waveform DSP
- Fully Automated Measurement System
- Waveform Pass/Fail Template Testing
- Color Display (TDS 654C, TDS 684C, TDS 694C)
- RS-232, Centronics, and GPIB Interfaces Included Standard
- Record Length to 120,000 Points/channel*
- Timebase Accuracy to 10 ppm, Time Interval Measurement Accuracy
to ± 15 ps (TDS 694C)
- Trigger Jitter 8 ps RMS (Typical)
- 1% Vertical Accuracy (TDS 694C)
- 100 ps Peak Detect (TDS 694C only)
Specifications
|
TDS
654C |
TDS
680C |
TDS
684C |
TDS
694C |
| Total Channels |
4 |
2 + 2 |
4 |
4 |
| Sample Rate
(all channels simultaneously) |
5
GS/s |
5 GS/s |
5 GS/s |
10 GS/s |
| Real-time Bandwidth |
500 MHz |
1 GHz |
1 GHz |
3 GHz |
| Maximum
Record Length per Channel |
15,000
pts |
15,000
pts |
15,000
pts |
120,000 pts |
| Vertical Resolution |
1 mV/div - 10 V/div |
1 mV/div - 10 V/div |
1 mV/div - 10 V/div |
10 mV/div - 1 V/div |
| Delta Time
Measurement Accuracy |
<
50 ps @ 5 GS/s |
<
50 ps @ 5 GS/s |
<
50 ps @ 5 GS/s |
15 ps
@ 10 GS/s |
| Advanced Waveform DSP/Math |
Std. |
Std. |
Std. |
Std. |
| Histograms
and Measurement Statistics |
Std. |
Std. |
Std. |
Std. |
| Standard Probes |
4 P6243 |
None |
None |
None |
| Display
Type |
7
in. NuColorTM Display |
7 in.
monochrome |
7 in.
NuColorTM Display |
7 in.
NuColorTM Display |
| Floppy Drive |
Std. |
Std. |
Std. |
Std. |
| GPIB, RS-232
& Centronics |
Std. |
Std. |
Std. |
Std. |
| VGA Output |
Std. Color |
Std. Mono |
Std. Color |
Std. Color |
| Hard Disk
Drive |
Opt. |
Opt. |
Opt. |
Opt. |
Time Base System
Time Bases - Main and delayed.
Time/div Range - 200 ps/div to 10 s/div.
except TDS 694C: 100 ps/div to 10 s/div.
Time Base Accuracy - Over any interval >1
ms ±100 ppm. Except TDS 694C: Over any interval > 1 ms
± 10 ppm.
Time Interval Measurement Accuracy -
TDS 654C/680C/684C: ±[(0.2/sample rate) + (100 ppm x |Reading|)]
single shot. (approximately 50 ps @ 5 GS/s)
TDS 694C: ±[(0.15/sample rate) + (10 ppm x |Reading|)] single
shot. (approximately 15 ps @ 10 GS/s)
Record Length per Channel - 500 to 15,000 pts.
except TDS 694C: 500 to 30,000 pts. (optional: 120,000 pts.)
Trigger Jitter - 8 ps RMS (typical).
Pre-Trigger Position - 0% to 100% of record.
Channel to Channel Deskew Range - ±25
ns.
Vertical System
Vertical Resolution - 8-Bits (>11-Bits with
averaging).
Vertical Sensitivity - 1 mV/div to 10 V/div.
Except TDS 694C: 10 mV/div to 1 V/div.
Maximum Input Voltage - 300 V CAT II;
±400 V peak. Derate at 20 dB/decade above 1 MHz.
Except TDS 694C: 5 V RMS.
DC Gain Accuracy - ±1.5%. Except TDS 694C:
±1.0%.
Position Range - ±5 divs.
Offset -
±1 V from 1 to 99.5 mV/div, ±10 V from 100 mV
to 995 mV/div, ±100 V from 1 V to 10 V/div.
Except TDS 694C: ±0.5 V from 10 to 50 mV/div, ±0.25 V
from 50.5 to 100 mV/div, ±5 V from 101 mV to 500 mV/div,
±2.5 V from 505 mV to 1 V/div.
Bandwidth Selections - 20 MHz, 250 MHz,
and Full. Except TDS 694C: Full only.
Input Impedance Selections - 1 megaohm in parallel
with 10 pF, or 50 Ohm (AC and DC coupling). Except TDS 694C:
50 Ohm (DC coupled).
Input Coupling - AC, DC or GND. Except TDS 694C:
DC or GND.
AC Coupled Low Frequency Limit (Except TDS 694C)
- <10 Hz when AC, 1 megaohm coupled. <200 kHz when
AC, 50 Ohm coupled.
Channel Isolation - >100:1 at 100 MHz
and >30:1 at BW for any two channels having equal V/div settings.
Acquisition Modes
Peak Detect - High frequency and random glitch
capture. Captures glitches of 1 ns using acquisition hardware at
all real-time sampling rates. TDS 694C captures glitches of 100 ps.
Sample - Sample data only.
Envelope - Max/min values acquired over one or
more acquisitions.
Average - Waveform data from 2 to 10,000 waveforms
(selectable) is averaged.
Single Sequence - Use RUN/STOP button to capture
a single triggered acquisition at a time, which may be automatically saved
to NVRAM with AutoSave.
Trigger Types
EDGE (Main and Delayed) -
Conventional level-driven trigger. Positive or negative slope on any channel
or rear panel auxiliary input. Coupling selections: DC, AC, noise reject,
HF reject, LF reject.
LOGIC (Main) -
PATTERN: Specifies a logical combination (AND, OR, NAND, NOR) of the four
input channels (high, low, don't care). Trigger when pattern stays true
or false for a specified time.
STATE: Any logical pattern of channels 1, 2, and 3 (AUX1 on TDS680C) plus
a clock edge on channel 4 (AUX2 on TDS680C). Triggerable on rising or
falling clock edge.
SETUP/HOLD: Trigger on violations of both setup time and hold time between
clock and data which are on two input channels.
PULSE (Main) -
GLITCH: Trigger on or reject glitches of positive, negative, or either
polarity. Minimum glitch width is 1.0 ns with 200 ps resolution.
RUNT: Trigger on a pulse that crosses one threshold but fails to cross
a second threshold before crossing the first again.
WIDTH: Trigger on width of positive or negative pulse either within or
out of selectable time limits (1 ns to 1 s).
SLEW RATE: Trigger on pulse edge rates that are either faster or slower
than a set rate. Edges can be rising, falling, or either.
TIMEOUT: Trigger on an event which remains high, low, or either, for a
specified time period, selectable from 1 ns to 1 s, with 200 ps
resolution.
TLA Cross Trigger (TDS 694C only) - Utilize a
TLA 700 logic analyzer to detect a multi-channel event, then trigger the
TDS 694C. The trigger points on the TLA and TDS will be aligned in time.
VIDEO (Optional; Not Available in TDS 694C) -
Trigger on a particular line of individual, odd/even, or all fields. Trigger
on a specific pixel of a line by using the video trigger with delay by
events. Choose positive or negative horizontal sync polarity.
525/NTSC: Choose monochrome or color (studio-quality NTSC) sync formats.
625/PAL: Choose color or monochrome (studio-quality PAL) sync formats.
HDTV: Choose from 1125/60, 1050/60, 1250/50, and 787.5/60 HDTV formats.
Trigger Bandwidth (Edge Type) -
3 GHz (TDS 694C).
1 GHz (TDS 684C, TDS 680C).
500 MHz (TDS 654C).
Main Trigger Modes - Auto, Normal, Single.
Delayed Trigger - Delay by time, events, or events
and time.
Delay by Time Range - 16 ns to 250 s.
Delay by Events Range - 2 to 9,999,999 events.
External Trigger Input - Input Impedance: >1.5
kilohm; Max. Input Voltage: ±20 V (DC + peak AC).
Display Characteristics
Waveform Style - Dots, vectors, variable persistence
from 32 ms to 10 s, infinite persistence, and intensified samples.
Color (TDS 694C, TDS 684C, TDS 654C) - Standard
palettes and user-definable color for waveforms, text, graticules, and
cursors. Measurement text and cursor colors matched to waveform. Waveform
collision areas highlighted with different color. Statistical waveform
distribution shown with color grading through variable persistence.
Color Grading (TDS 694C, TDS 684C, TDS 654C)
- With variable persistence selected, historical timing information is
represented by temperature or spectral color scheme (or gray scale on
TDS 680C).
Graticules - Full, grid, cross-hair, frame, and
NTSC and PAL (with video trigger option).
Format - YT and XY.
Resolution - 640 horizontal by 480 vertical displayed
pixels (VGA).
Color CRT Monitor (TDS 654C/684C/694C) - 7 in.
diagonal NuColorTM liquid crystal full-color shutter, 256 levels.
Monochrome CRT Monitor (TDS 680C) - 7 in. diagonal,
magnetic deflection. Horizontal raster-scan. P4 white phosphor.
Measurement System
Automatic Waveform Measurements -
Period, frequency, + width, - width, rise time, fall time, + duty cycle,
- duty cycle, delay, phase, burst width, high, low, max, min, peak to
peak, amplitude, + overshoot, - overshoot, mean, cycle mean, RMS, cycle
RMS, area, cycle area, extinction ratio (ratio, dB, %), and mean
optical power. Continuous update of up to four measurements on any combination
of waveforms.
Measurement Statistics - Display minimum and
maximum or mean and standard deviation on any displayed single-waveform
measurements.
Thresholds - Settable in percentage or voltage.
Gating - Any region of the waveform may be isolated
for measurement using vertical bars.
Snapshot - Performs all measurements on any one
waveform showing results from one instant in time.
Cursor Measurements - Absolute, Delta: Volts,
Time, Frequency, and NTSC IRE and line number (with video trigger option).
Cursor Types - Horizontal bars (volts), vertical
bars (time); operated independently or in tracking mode.
Histogram Measurements - Mean, median, standard
deviation, hits, waveform count, peak hits, peak to peak, % mean ±
1, 2, and 3 standard deviations.
Waveform Processing
Waveform Functions - Interpolation (sin(x)/x
or linear), Average, Envelope, Auto Setup.
Advanced Waveform Functions - FFT, Integration,
Differentiation, Waveform (math or acquired) Limit Testing.
Arithmetic Operators - Add, Subtract, Multiply,
Divide, Invert.
Autoset - Single-button, automatic setup on selected
input signal for vertical, horizontal, and trigger systems.
Waveform Limit Testing - Compares incoming or
math waveform to a reference waveform's upper and lower limits.
Waveform Histograms - Both vertical and horizontal
histograms, with periodically updated measurements, allow statistical
distributions to be analyzed over any region of the signal.
Zoom Characteristics
The zoom feature allows waveforms to be expanded
or compressed in both vertical and horizontal axes. Allows precise comparison
and study of fine waveform detail without affecting ongoing acquisitions.
When used with Average acquisition modes, Zoom provides an effective vertical
dynamic range of 1000 divisions or 100 screens.
Dual Window Zoom - Dual graticules simultaneously
show selected and zoomed waveforms. Up to two zoom boxes show areas on
the selected trace that are being magnified, and the two magnified areas
can be overlapped for quick comparison. Color of zoomed trace matches
selected trace.
Computer Interface
GPIB (IEEE-488.2) Programmability - Full talk/listen
modes. Control of all modes, settings, and measurements.
Hardcopy
Printer - HP Thinkjet, Deskjet, Laserjet, Epson,
Interleaf, PostScript, TIFF, PCX, BMP, DPU411/412, RLE.
Plotter - HPGL.
Data - MathCad, spreadsheet formats.
Hardcopy Interface - Centronics and RS-232 (talk
only).
Data Storage
Standard - Internal MS-DOS 1.44 Mbyte floppy,
external Iomega ZipTM drive support.
Optional - Internal hard disk drive.
Non-volatile Storage for Setups - 10 front panel
setups.
Floppy Disk Drive - Store reference waveforms,
setups, and image files on 3.5 in. 1.44 MB or 720 K DOS-format floppy
disk.
Iomega ZipTM Drive Compatible - Compatible
for waveform, hardcopy, and front panel setup file transfer to Iomega
ZipTM, ZipPlusTM, and Zip250TM Drive.
Power Requirements
Line Voltage Range - 90 to 250 V RMS.
Line Frequency - 45 to 440 Hz.
Power Consumption -
300 W max. (TDS 654C/680C/684C).
450 W max. (TDS 694C).
Environmental and Safety
Temperature -
Operating: +4° C to +45° C (floppy not used), +10° C to +45°
C (floppy in use). Non-operating: -22° C to +60° C.
TDS 694C: Operating: +5°C to +40°C (floppy not used), +10°C
to +40°C (floppy in use). Non-operating: -22°C to +60°C.
Humidity -
Operating: 20% to 80% RH at or below +32°C.
Altitude -
Operating: 15,000 ft. (hard disk not used), 10,000 ft. (hard disk in use).
Non-operating: 40,000 ft.
Electromagnetic Compatibility - UL1244.
Safety - UL 3111-1, CSA1010.1, EN61010-1, IEC61010-1.
Physical Characteristics
| Dimensions |
mm |
in. |
| Height with feet |
193 |
7.6 |
| Height
without feet |
178 |
7 |
| Width with handle |
445 |
17.5 |
| Depth
with front cover installed |
434 |
17.1 |
| Weight |
kg |
lbs. |
| Net approximately |
14.1 |
31 |
| Shipping
Weight approximately |
24.0 |
53 |
Specs
|