Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
MetricTest Equipment Logo   Advanced
1.800.417.4370
 

TEK TDS820 Digital Sampling Oscilloscopes

Features

  • 2 Input Channels
  • 20 ps/div to 2 ms/div Sweep Speeds in 5 ps Steps
  • 2 GHz External Trigger Bandwidth
  • 3 ps RMS Jitter
  • Infinite and Variable Persistence Displays
  • 14-Bit Vertical Resolution
  • 27 Automatic Measurements
  • Full GPIB Programmability
  • Optional Hardcopy Interface
  • Optional Advanced DSP Waveform Math Including FFT, Integration and Differentiation
Applications
  • Telecom Service and Manufacturing
  • Semiconductor Characterization
  • Digital System Design and Characterization
  • Electronic Mask Drawing and Display
  • Automatic Pass/Fail Limit Testing

Specifications

SIGNAL Acquisition System

TDS 820

TDS 820 Opt. 1D

Channels

2

2

Rise time

58.3 ps

43.8 ps

Bandwidth (0.35/rise time)

6 GHz

8 GHz

Max operating input voltage

2 Vp-p; ±3 V DC

1 Vp-p; ±1.5 V DC

Sensitivity

2 m V/div to 200 mV/div

1 mV/div to 100 mV/div

Random noise

1.2 mV max, 600 µV typical

600 µV max, 300 µV typical

 

DC Gain Accuracy - ±0.7% after user-initiated automatic vertical calibration.

Vertical Resolution - 14-Bits (Approx. 16,384 levels over 10.24 vertical divisions).

Input Impedance - 50 Ohm.

Acquisition Modes

Normal - One sample acquired with each trigger event.

Envelope - Max/min values acquired over one or more acquisitions.

Average - Waveform averages selectable from 2 to 10,000.

Time Base System

Time Bases - Main, Delayed.

Time/Division Range - 20 ps/division to 5 ms/division in 1-2-5 steps or settable from the numeric keypad in 5 ps steps.

Delta time measurement accuracy -

Time interval

Accuracy

Ti >1 ns

0.1% x interval +15ps

100 ps

5 ps

10 ps

2 ps

Channel Deskew - Up to 100 ns (each channel).

Record Length - 500, 1000, 2000, and 5000, and 15,000 samples per channel.

Pre -Trigger View Time - 1.5 ns.

Triggering System

Trigger Sources - External input, internal rate generator, CH 1, CH 2.

External Trigger Sensitivity - 40 mVp-p from DC to 200 MHz, increasing linearly to 200 mVp-p at 2 GHz.

External Trigger Minimum Pulse Width - 0.25 ns.

Internal Trigger Sensitivity - 80 mVp-p from DC to 200 MHz, increasing linearly to 400 mVp-p at 1 GHz.

Trigger Delay Jitter - 3 ps RMS + 30 ppm of time base delay.

Holdoff Range - 15 µs to 2 s.

Display

Waveform Style - Dots or vectors. Infinite and variable persistence from 250 ms to 10 s.

Gray Scaling - With variable persistence selected, waveform points gradually decay through 16 levels of intensity, providing "z-axis" information about rapidly changing waveforms.

Graticules - Full, grid, cross hair, frame.

Format - YT and XY.

CRT Type - 7 in. diagonal, magnetic deflection. Horizontal raster-scan. P4 White phosphor.

CRT Resolution - 640 horizontal by 480 vertical displayed pixels.

Measurement System

Automatic waveform measurements -

Period

Frequency

High

Low

+ Width

- Width

Maximum

Minimum

Rise

Fall

Peak to Peak

Amplitude

+ Duty Cycle

- Duty Cycle

+ Overshoot

- Overshoot

Propagation Delay

Burst Width

Mean

Cycle Mean

RMS

Cycle RMS

Phase

Cycle Area

+ Cross

- Cross

Area


Continuous update of up to four measurements on any combination of waveforms. Snapshot mode shows all measurements on the selected waveforms.

Thresholds - Settable in percentage or voltage.

Cursor Measurements - Absolute, Delta; Volts, Time, Frequency.

Cursor Types - Horizontal bars (volts); Vertical bars (time); Paired (volts and time).

Waveform Processing

Waveform Functions - Interpolate-selectable sin(x)/x or linear, Average, FFT, integrate, and differentiate.

Arithmetic Operators - Add, Subtract, Multiply, Invert.

Autosetup - Single button, automatic setup on selected input signal for vertical, horizontal and trigger systems.

Computer Interface

GPIB (IEEE -488.2) Programmability - Full talk/listen modes. Control of all modes, settings, and measurements.

Hard Copy

Formats - HP ThinkJet, Epson, Postscript, Interleaf, DeskJet, LaserJet, EPS Monochrome, EPS Color, TIFF, PCX, BMP, HPGL.

Optional Hardcopy Interface - Centronics and RS-232C.

Storage

Waveforms - Up to 15 K points.

Setups - 10 front-panel setups.

Power Requirements

Line Voltage Range - 90 to 250 V RMS.

Line Frequency - 47 to 63 Hz.

Power Consumption - 250 W max.

Environment and Safety

Temperature - Operating: 0 to +50°C. non-operating: -40 to +75°C.

Humidity - Operating and non-operating: Up to 95% relative humidity at or below +40°C; to 75% relative humidity from +41°C to 50°C.

Altitude - Operating: 15,000 ft. non-operating: 40,000 ft.

Electromagnetic Compatibility - Meets MIL-STD-461C, CE-03, Part 4, Curve # 1, RE-02, Part 7; meets VDE 0871, Category B, FCC rules and regulations, Part 15, Subpart B, Class A.

Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010-1.

Physical Characteristics

Dimensions

mm

in.

Height

193

7.6

with acc. pouch

236

9.3

Width

445

17.5

Depth with front cover

432

17

Weight

kg

lbs.

Net

13.2

29.1

Shipping

23.6

52

 

Ordering Information

TEK TDS820 Digital Sampling Oscilloscopes

TEK TDS820 6GHz Digital Oscilloscope

 

Continuous update of up to four measurements on any combination of waveforms. Snapshot mode shows all measurements on the selected waveforms.

Thresholds - Settable in percentage or voltage.

Cursor Measurements - Absolute, Delta; Volts, Time, Frequency.

Cursor Types - Horizontal bars (volts); Vertical bars (time); Paired (volts and time).

Waveform Processing

Waveform Functions - Interpolate-selectable sin(x)/x or linear, Average, FFT, integrate, and differentiate.

Arithmetic Operators - Add, Subtract, Multiply, Invert.

Autosetup - Single button, automatic setup on selected input signal for vertical, horizontal and trigger systems.

Computer Interface

GPIB (IEEE -488.2) Programmability - Full talk/listen modes. Control of all modes, settings, and measurements.

Hard Copy

Formats - HP ThinkJet, Epson, Postscript, Interleaf, DeskJet, LaserJet, EPS Monochrome, EPS Color, TIFF, PCX, BMP, HPGL.

Optional Hardcopy Interface - Centronics and RS-232C.

Storage

Waveforms - Up to 15 K points.

Setups - 10 front-panel setups.

Power Requirements

Line Voltage Range - 90 to 250 V RMS.

Line Frequency - 47 to 63 Hz.

Power Consumption - 250 W max.

Environment and Safety

Temperature - Operating: 0 to +50°C. non-operating: -40 to +75°C.

Humidity - Operating and non-operating: Up to 95% relative humidity at or below +40°C; to 75% relative humidity from +41°C to 50°C.

Altitude - Operating: 15,000 ft. non-operating: 40,000 ft.

Electromagnetic Compatibility - Meets MIL-STD-461C, CE-03, Part 4, Curve # 1, RE-02, Part 7; meets VDE 0871, Category B, FCC rules and regulations, Part 15, Subpart B, Class A.

Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010-1.



 
 
  Company    |   Contact Us   |   Site Map 1.800.417.4370
 
 
 
 
Copyright©2008 MetricTest. All rights reserved. Privacy & Security