Home >
Tektronix > TDS700 Series
Tektronix TekScope® THS730A * THS720A * THS720P
|
THS730A |
THS720A |
THS720P |
|
| Bandwidth | 200 MHz | 100 MHz | 100 MHz |
| Sample Rate (Each Channel) | 1 GS/s | 500 MS/s | 500 MS/s |
| Time/Division Range | 2 ns to 50 s/div | 5 ns to 50s/div | 5 ns to 50s/div |
| Power Measurements | N | N | Y |
Channels - Two.
Sensitivity - 5 mV to 50 V/div (to 500 V/div with 10X probe).
Position Range - ±10 div.
DC Gain Accuracy - ±2%.
Vertical Resolution - 8-Bits.
Record Length - 2500 points.
Time/Division Range (THS720P only) - 5 ns to 50 s/div.
Horizontal Accuracy - ±200 ppm.
Roll Mode - > 0.5 s/div.
Autorange - User-selectable.
Trigger Modes - Auto, Normal.
Trigger Types - Edge, Pulse, Video, External, Motor (THS720P).
Video Trigger Formats and Field Rates - Odd field, even field and line.
Motor Trigger (THS720P only) - Triggers on 3- and 5-level pulse-width modulated power signal.
External Trigger Input - 5 MHz TTL compatible.
Harmonics (THS720P only) - Up to 31st (30 Hz-450 Hz).
Waveform Processing - Add, Subtract, Multiply, Calculate Watts = V x I.
Waveform Storage - 10 waveforms.
Acquisition Modes - Sample, Envelope, Average, Peak Detect.
Cursor Measurements - delta Volts, delta Time, 1/deltaTime (Hz), Degree (phase).
Cursor Types - Horizontal Bars, Vertical Bars, Paired (volts @ time).
Display System - Interpolation: Sin(x)/x.
Format: YT and XY.
Mode: Vector, Dot, Vector Accumulate, Dot Accumulate.
| Period | Frequency |
| +Width | -Width |
| Rise time | Fall time |
| +Duty cycle | -Duty cycle |
| +Overshoot | -Overshoot |
| High | Max |
| Low | Min |
| Peak-to-Peak | Amplitude |
| Mean | RMS |
| Cycle mean | Cycle RMS |
| Burst width |
W |
True power
|
VA |
Apparent power
|
VAR |
Reactive power
|
V |
Volts (RMS, Peak)
|
A |
Amps (RMS, Peak)
|
THD-F |
Total harmonic distortion as a percentage of the
fundamental
|
THD-R |
Total harmonic distortion of the RMS of the input
signal
|
PF |
Power factor
|
DPF |
Displacement power factor
|
PHI |
Phase difference between the voltage and current
|
DC Voltage Ranges - 400.0 mV to 880 V.
DC Volts Accuracy - ±(0.5% of reading + 5 counts).
True RMS AC Voltage Ranges - 400.0 mV to 640 V.
Maximum Float Voltage - 600 VRMS CAT II, each channel (probe dependent).
Resolution - 4000 count, 3-3/4 digits.
AC Volts Accuracy - ±(2% of reading + 5 counts).
Resistance Ranges - 400.0 Ohm to 40.00 megaohm.
Resistance Accuracy - ±(0.5% of reading + 2 counts); 40 megaohm: ±(2% of reading + 5 counts).
Diode Test Range - 0 to 2 V.
Continuity Check - Audible tone when < 50 Ohm.
Modes - Min, Max, Delta, Max-Min, Avg, Hold.
Nonvolatile Storage - 10 DMM screenshots.
External Trigger Input - 5 MHz TTL compatible.
Vertical Zoom Capability - 2X, 5X, 10X.
dB Scale - Selectable, referenced from 1 mV to 10 V.
dBm Scale - Selectable, referenced from 50 Ohm to 600 Ohm.
Setups - 10 front-panel setups.
Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010.1.
EMC - Meets Directive 89/336/EEC.
Power - NiCd rechargeable battery pack with AC adapter (both included).
Battery Life - Approx. 2 hours from full charge.
Display - Backlit LCD.
Display Resolution - 320 x 240.
| Dimensions | mm | in. |
| Width | 177 | 6.95 |
| Height | 217 | 8.53 |
| Depth | 51 | 2 |
| Weight | kg | lbs. |
| Net | 1.45 | 3.2 |
|
|||||
|
|||||