Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
MetricTest Equipment Logo   Advanced
1.800.417.4370
 
 

-

-

Tektronix TekScope® THS730A * THS720A * THS720P
Handheld Battery Operated Oscilloscope/DMM/Power Analyzers

Characteristics

Oscilloscope Functions


THS730A

THS720A

THS720P

Bandwidth 200 MHz 100 MHz 100 MHz
Sample Rate (Each Channel) 1 GS/s 500 MS/s 500 MS/s
Time/Division Range 2 ns to 50 s/div 5 ns to 50s/div 5 ns to 50s/div
Power Measurements N N Y

Oscilloscope Functions

Channels - Two.

Sensitivity - 5 mV to 50 V/div (to 500 V/div with 10X probe).

Position Range - ±10 div.

DC Gain Accuracy - ±2%.

Vertical Resolution - 8-Bits.

Record Length - 2500 points.

Time/Division Range (THS720P only) - 5 ns to 50 s/div.

Horizontal Accuracy - ±200 ppm.

Roll Mode - > 0.5 s/div.

Autorange - User-selectable.

Trigger Modes - Auto, Normal.

Trigger Types - Edge, Pulse, Video, External, Motor (THS720P).

Video Trigger Formats and Field Rates - Odd field, even field and line.

Motor Trigger (THS720P only) - Triggers on 3- and 5-level pulse-width modulated power signal.

External Trigger Input - 5 MHz TTL compatible.

Harmonics (THS720P only) - Up to 31st (30 Hz-450 Hz).

Waveform Processing - Add, Subtract, Multiply, Calculate Watts = V x I.

Waveform Storage - 10 waveforms.

Acquisition Modes - Sample, Envelope, Average, Peak Detect.

Cursor Measurements - delta Volts, delta Time, 1/deltaTime (Hz), Degree (phase).

Cursor Types - Horizontal Bars, Vertical Bars, Paired (volts @ time).

Display System - Interpolation: Sin(x)/x.
Format: YT and XY.
Mode: Vector, Dot, Vector Accumulate, Dot Accumulate.

Automatic Measurements

Period Frequency
+Width -Width
Rise time Fall time
+Duty cycle -Duty cycle
+Overshoot -Overshoot
High Max
Low Min
Peak-to-Peak Amplitude
Mean RMS
Cycle mean Cycle RMS
Burst width

Power Measurements (THS720P Only) -

W

True power

VA

Apparent power

VAR

Reactive power

V

Volts (RMS, Peak)

A

Amps (RMS, Peak)

THD-F

Total harmonic distortion as a percentage of the fundamental

THD-R

Total harmonic distortion of the RMS of the input signal

PF

Power factor

DPF

Displacement power factor

PHI

Phase difference between the voltage and current

DMM Specifications

DC Voltage Ranges - 400.0 mV to 880 V.

DC Volts Accuracy - ±(0.5% of reading + 5 counts).

True RMS AC Voltage Ranges - 400.0 mV to 640 V.

Maximum Float Voltage - 600 VRMS CAT II, each channel (probe dependent).

Resolution - 4000 count, 3-3/4 digits.

AC Volts Accuracy - ±(2% of reading + 5 counts).

Resistance Ranges - 400.0 Ohm to 40.00 megaohm.

Resistance Accuracy - ±(0.5% of reading + 2 counts); 40 megaohm: ±(2% of reading + 5 counts).

Diode Test Range - 0 to 2 V.

Continuity Check - Audible tone when < 50 Ohm.

Modes - Min, Max, Delta, Max-Min, Avg, Hold.

Nonvolatile Storage - 10 DMM screenshots.

External Trigger Input - 5 MHz TTL compatible.

Vertical Zoom Capability - 2X, 5X, 10X.

dB Scale - Selectable, referenced from 1 mV to 10 V.

dBm Scale - Selectable, referenced from 50 Ohm to 600 Ohm.

General Specifications

Setups - 10 front-panel setups.

Safety - UL3111-1, CSA1010.1, EN61010-1, IEC61010.1.

EMC - Meets Directive 89/336/EEC.

Power - NiCd rechargeable battery pack with AC adapter (both included).

Battery Life - Approx. 2 hours from full charge.

Display - Backlit LCD.

Display Resolution - 320 x 240.

Physical Characteristics

Dimensions mm in.
Width 177 6.95
Height 217 8.53
Depth 51 2
Weight kg lbs.
Net 1.45 3.2



 
 