Home   |   Contact Us   |   Shopping Cart   |   Quote Cart  0 items   |   Login
Electronic Test Equipment - MetricTest   Advanced
1.800.417.4370
 
 

TEK URV5 Power Meter

Features

The URV 5 RF Millivoltmeter is a broadband voltage, level and power meter with high accuracy and sensitivity. It is suitable for both manual operation and use in systems. A great variety of probes, sensors and accessories allows the URV 5 to be used for all kinds of measurements.

The values measured in the two channels can be displayed separately, set off against one another or referred to any reference. For relative measurements, the difference, difference in percent, logarithmic difference or ratio is indicated (DELTAV, DELTAW, DELTA%, DELTAdB, X/REF).

The URV 5 has a fast trend indication which follows the variations of the measured value.

URV 35 Level Meter

The URV 35 Level Meter is a precise voltage and power meter for a large variety of applications. It can be used in service and production, as well as for precision measurement in the RF and microwave lab.

The large variety of probes and sensors available opens up a wide level and frequency range. Excellent RF shielding provides precise measurements, even in the near field of antennas.

An intelligent operating concept in conjunction with an auto-range facility reduces the user's work to read the results in standard units, either as absolute or relative values. The appropriate scale is shown on the LCD display for convenient reading of the results.

Filtering, which is dependent upon the level and resolution, as well as the choice between 4 1/2- and 3 1/2-digit readout, optimizes the display of results. Each probe and sensor is calibrated individually. All relevant data of the probes are automatically evaluated in the URV 35.

  • DC to 26.5 GHz Frequency Range
  • Compact, Handy and Mobile
  • Voltmeter and Power Meter in One Unit
  • Combined Analog and Digital Display
  • Menu-guided Operation
  • DC Frequency Input for Tracking Frequency-response Correction
  • Analog Output of YT Recorder
  • Remote Control Interface
  • Battery or AC Supply Operation
  • Wide Choice of Probes and Sensors
  • Rugged Design
Applications
  • Service
  • Production
  • Precision Measurements in RF and Microwave Labs

Specifications

Optional DC Output (URV 5 with Opt. 01) -
Output voltage range (EMF): -1.999 to +1.999 V into Zout = 1 kilohm.
Resolution: 1 mV (10 digits).
Error: ±2 mV.

Remote Control -
Interface: IEC625-1 (IEEE 488) for control of all device functions.
Interface functions: SH1, AH1, T5, L4, SR1, RL1, DC1, DT1, PP1.

Physical Characteristics
Dimensions mm in.
Height 110 4.3
Width 241 9.5
Depth 340 13.4
Weight kg lbs.
Net 4.4 9.7

URV 35

Probes and Sensors - Compatible with all URV 5-Z probes and NRV-Z sensors.

Frequency Range - DC to 26.5 GHz.

Display - Backlit LCD for display of measured value, units and meter scale; additional moving-coil meter with short response time.
Absolute readout: dBm, dBµV, V or W.
Relative readout: dB referred to stored reference value.
Resolution of digital display -
4 ½ digits: 19,999 steps, 0.001 dB.
3 ½ digits: 1,999 steps, 0.01 dB.
Analog display: Steps of 1/2.5/5 with readout in V, W, or dB; steps of 5 dB with readout in dBm and windows of 10 dB, manually or automatically selected; free scaling by entry of left-hand and right-hand scale limits.
Display filtering: Level-dependent digital averaging filter.
4 ½-digit resolution: Averaging over 16 to 256 readings.
3 ½-digit resolution: Averaging over 1 to 32 readings.

Error Limits (18 to 28°C) -
Digital display: ±0.02 dB ±1 digit.
Moving-coil meter: 1.5% of full scale.

Zero Adjustment - Via interface or manually, approximately 4 s.

HOLD Function - Displayed measurement result retained upon keystroke.

Measurement Rate - Five readouts per second in manual mode.

Frequency-response Correction - Specific calibration data of probe taken into account; frequency entry via keypad, interface or equivalent DC voltage at rear-panel input.

Attenuation Correction - Attenuation or gain connected to input taken into account; input of attenuation value via serial interface or keypad, range ±199.99 dB.

Reference Value Entry - Measured value on keystroke or value entered via interface or keypad.

Reference Impedance - 50 Ohm/75 Ohm, automatic/selectable.

Input/Output -
DC frequency input:
Connector: BNC female.
Input impedance: 9 megaohm.
Input voltage range: ±12 V, freely selectable, linear, scaling.
Maximum input voltage: 50 V.
DC Voltage Output:
Connector: BNC female.
Source impedance: 1 kilohm.
Output voltage (EMF): Proportional to pointer deflection.
Left-hand scale limit: Corresponding to 0 V.
Right-hand scale limit: Corresponding to 0 V.
Settling time: 250 ms.
Error: </=5 mV.
Ripple: 5 mV p-p typical.

Remote Control - All device functions controlled via serial interface (V.24, RS-232C).

Power Requirements (URV 5 and URV 35)

Battery Operation (URV 35 Model 02) -
Battery type: 5 LR20 (1.5 V).
Operating time: Approximately 125 hours.
Charge time (with UZ-35 charger): Approximately 24 hours.

AC Operation (URV 5 and URV 35 Model 03) -
Line voltage: 100/120/220/240 VAC ±10%.
Line frequency: 47 to 63 Hz, 400 Hz.
Power consumption: 30 VA.

Environmental Characteristics (URV 5 and URV 35)

Temperature Range -
Operating: 0 to +50°C (Class I to IEC 359, no condensation).
Storage: -40 to +70°C.

Humidity - 80% maximum (without condensation).

Mechanical Strength - To IEC 359, Class I.

RFI Suppression - VDE 0871, DBP approval number to regulations 527/1979.

EMC - To IEC 801.3, severity level 3; MIL-STD-461-B RS 03 and CS 02.

Physical Characteristics
Dimensions mm in.
Height 103 4.1
Width 219 6.6
Depth 240 9.4
Weight kg lbs.
Model 02

With batteries 3.1 6.8
Without batteries 2.3 5.1
Model 03 2.4 5.3
 


 
 
  Company    |   Contact Us   |   Site Map 1.800.417.4370
 
 
 
 
Copyright©2008 MetricTest. All rights reserved. Privacy & Security