 Agilent Network Analyzers Selection Guide

  Frequency range Number of ports Balanced measurements* System impedance ECal support Measurement speed (1 sweep, 201 points)

Vector 5100A

10 kHz to 300 MHz 2 No 50 ohms No 8 ms (1-port cal, ramp-sweep)
64 ms (1-port cal, step-sweep)

Combination Network/spectrum/impedance
4395A & 4396B

10 Hz to 1.8 GHz 2 No 50 or 75 ohms No 165 ms (response cal, gain, 30 kHz BW)
215 ms (response cal, gain and phase, 30 kHz BW)

Vector
8712ES/ET; 8714ES/ET

300 kHz to 3 GHz 2 No 50 or 75 ohms No 72 ms (1-port cal, 6.5 kHz BW)
119 ms (1-port cal, 4.0 kHz BW)
240 ms (2-port cal, 4.0 kHz BW, ES model only)

Vector
8753ES/ET

30 kHz to 6 GHz 2 No 50 or 75 ohms Yes 70 ms (1-port cal)
139 ms (2-port cal, ES model only)
(6 kHz BW)

Vector
E5070B; E5071B

300 kHz to 8.5 GHz 2, 3, or 4 Yes 50 ohms Yes 8 ms (2-port cal)
(100 kHz BW)

Vector
E8356/7/8A; E8801/2/3A; N3381/2/3A

300 kHz to 9 GHz 2 or 3 No 50 ohms Yes 29 ms (2-port cal)
(35 kHz BW)

Vector
8719ES/ET; 8720ES/ET; 8722ES/ET

50 MHz to 40 GHz 2 No 50 ohms Yes 65 ms (1-port cal)
158 ms (2-port cal, ES model only)
(6 kHz BW)

Vector
E8362/3/4B; E8361A

10 MHz to 67 GHz 2 No 50 ohms Yes 29 ms (2-port cal)
(35 kHz BW)

Vector 8510

45 MHz to 110 GHz 2 No 50 ohms No 50 ms (1 trace)

Scalar 8757D

10 MHz to 110 GHz 2 No 50 ohms No 470 ms (2-port cal)
(10 kHz BW)
 
 