Fluke ScopeMeter® Test Tools Selection Guide
| |
190C Color ScopeMeter Series |
190B ScopeMeter Series |
Fluke 120 Series |
| |
199C |
196C |
199B |
196B |
192B |
124 |
123 |
| Bandwidth |
200 MHz |
100 MHz |
200 MHz |
100 MHz |
60 MHz |
40 MHz |
20 MHz |
| Max Real time Sample Rate |
2.5 GS/s |
1.0 GS/s |
2.5 GS/s |
1.0 GS/s |
0.5 GS/s |
25 MS/s |
25 MS/s |
| Max Record Length (per input) |
1200 Points |
512 Points (min/max pairs) |
| Number of Inputs |
2 Scope and 1 DMM (Isolated) |
2 Scope Or DMM |
| Input Sensitivity |
2 mV/div. to 100 V/div. |
5 mV/div. to 100 V/div. |
5 mV/div. to 500 V/div. |
| Independently Isolated floating Inputs |
yes |
no |
| Display & Display Modes |
| Display |
Color |
Monochrome |
Monochrome |
| Persistence |
Digital with variable decay |
On/Off |
no |
| Envelope Mode |
yes |
yes |
| Waveform Compare |
yes |
no |
| Pass/Fail Testing |
yes |
no |
no |
| Triggering |
| Connect-and-View™ Trigger |
yes |
yes |
| Edge, Single, Free Run |
yes |
yes |
| Video |
yes |
yes |
| Video Lines |
yes |
yes |
| Pulse Width |
yes |
no |
| Externayes |
yes |
With ITP 120 Option |
| Advanced Functions |
| Cursors |
yes |
yes |
no |
| Zoom |
yes |
no |
| Dual Input Trendplot™ |
yes |
yes |
| ScopeRecord™ Mode |
yes |
no |
| Automatic Capture & Replay last 100 Screens |
yes |
no |
| Waveform Mathematics |
yes |
no |
| Save Setups & Screens |
10 |
20 |
10 |
| True RMS Multimeter |
5000 Counts Volts, Amps, Ohms, Continuity, Diode, Temp |
| Safety, Power & Warranty |
| Safety (EN61010-1) |
1000 V CAT II / 600 V CAT III |
600 V CAT III 1 |
| Battery |
4 hr Ni-MH |
7 hr NiMH |
4 hr NiCd |
| Line Power |
Adapter / battery charger included |
| PC Printer Interface |
Using Optional Optically Isolated RS-232 adapter cable PM9080 |
| Warranty |
3 Year on main instrument. 1 year on standard accessories |
1 Max Input voltage 1000 V CAT