 HP / Agilent Network Analyzer Reference Chart

Model Frequency Range Source Measurement Capabilities
3577B 5 Hz to 200 MHz Integrated synthesized source Transfer functions, magnitude/phase, group delay, S-parameters, insertion loss, gain/attenuation, electrical length, gain compression, SWR, impedance, HP Instrument BASIC optional. HP-IB programmable.
3589A 10 Hz to 150 MHz Integrated synthesized source Transfer functions, magnitude/phase, group delay, S-parameters, impedance, SWR, spectrum analysis, including gating. HP Instrument BASIC optional. HP-IB programmable.
4195A 10 Hz to 500 MHz Integrated synthesized source Transfer functions, magnitude/phase, insertion loss/gain, attenuation, group delay, S-parameters, return loss, SWR, complex impedance, accuracy enhancement. HP-IB programmable.
4395A 10 Hz to 500 MHz Integrated synthesized source Combination network and spectrum analyzer with optional impedance measurements.
4396A/B 100 kHz to 1.8 GHz Integrated synthesized source Transfer functions, magnitude/phase, insertion loss/gain, attenuation, S-parameters, group delay, return loss, R + jX. Impedance-magnitude/phase. Electrical delay. Spectrum analysis. HP Instrument BASIC capability. Built-in 3.5-inch flexible disk (LIF/DOS format). HP-IB programmable.
8711B/C 300 kHz to 1.3 GHz Integrated synthesized source,
T/R test set and receiver
Transmission/reflection measurements. 50 ohm and 75 ohm measurements. HP Instrument BASIC (IBASIC). Narrowband/broadband receivers. Internal calibration. averaging, limit testing, internal disk and storage registers. For magnitude measurements.
8712B/C 300 kHz to 1.3 GHz Integrated synthesized source,
T/R test set and receiver
Transmission/reflection measurements. 50 ohm and 75 ohm measurements. HP Instrument BASIC (IBASIC). Narrowband/broadband receivers. Internal calibration. averaging, limit testing, internal disk and storage registers. Adds vector measurements to 8711B.
8713B/C 300 kHz to 3 GHz Integrated synthesized source,
T/R test set and receiver
Transmission/reflection measurements. 50 ohm and 75 ohm measurements. HP Instrument BASIC (IBASIC). Narrowband/broadband receivers. Internal calibration. averaging, limit testing, internal disk and storage registers. For magnitude measurements.
8714B/C 300 kHz to 3 GHz Integrated synthesized source,
T/R test set and receiver
Transmission/reflection measurements. 50 ohm and 75 ohm measurements. HP Instrument BASIC (IBASIC). Narrowband/broadband receivers. Internal calibration. averaging, limit testing, internal disk and storage registers. Adds vector measurements to 8713B.
8714ES 300 kHz to 3 GHz Integrated synthesized source S-parameter measurements. 50 ohms. Magnitude and phase. HPIB.
8720C 50 MHz to 20 GHz Integrated synthesized source
(1 Hz resolution optional)
Transfer functions, magnitude/phase, insertion loss/gain, attenuation, S-parameters, electrical length, group delay, deviation from linear phase. Impedance-magnitude/phase, return loss, R + jX, full accuracy enhancement, time-domain capability. HP-IB programmable.
8720D 50 MHz to 20 GHz Integrated synthesized source
(1 Hz resolution optional)
NEWEST version. Transfer functions, magnitude/phase, insertion loss/gain, attenuation, S-parameters, electrical length, group delay, deviation from linear phase. Impedance-magnitude/phase, return loss, R + jX, full accuracy enhancement, time-domain capability. HP-IB programmable.
8720ES 50 MHz to 20 GHz Integrated synthesized source S-parameter measurements. 50 ohms. Magnitude and phase. HPIB.
8722ES 50 MHz to 40 GHz Integrated synthesized source S-parameter measurements. 50 ohms. Magnitude and phase. HPIB.
8751A 5 Hz to 500 MHz Integrated synthesized source Transfer functions, magnitude/phase, insertion loss/gain, attenuation, gain compression, S-parameters, electrical length, group delay, deviation from linear phase. Impedance-magnitude/phase, return loss, R + jX. Full accuracy enhancement. HP Instrument BASIC capability. Built-in 3.5-inch flexible disk (LIF/DOS format). HP-IB programmable.
8752A/C 300 kHz to 1.3/3 GHz Integrated synthesized source,
test set, and receiver
Transfer functions, magnitude/phase, insertion loss/gain, attenuation, gain compression, S-parameters, electrical length, group delay, deviation from linear phase. Impedance-magnitude/phase, return loss, R + jX, full accuracy enhancement, time-domain capability. HP-IB programmable.
8753C 300 kHz to 3/6 GHz Integrated synthesized source Transfer functions, magnitude/phase, insertion loss/gain, attenuation, gain compression, S-parameters, electrical length, group delay, deviation from linear phase. Impedance-magnitude/phase, return loss, R + jX, accuracy enhancement, time-domain capability, harmonic measurement capability. HP-IB programmable.
8753D/E 30 kHz to 3/6 GHz Integrated synthesized source Same capabilities as the 8753C with a built-in S-parameter test set for faster, more accurate measurements.
8753E 30 kHz to 3/6 GHz Integrated synthesized source Same capabilities as 8753D with newer processor. Measurement and data transfer speeds are three to seven times faster.
8753ES 30 kHz to 3/6 GHz Integrated synthesized source S-parameter measurements. 50 ohms. Magnitude and phase. HPIB.
8757C/D/E 10 MHz to 110 GHz 8350B Sweeper
83751A/83752A Synthesized Sweepers
8360 Series Synthesized Sweepers
Scalar transmission/reflection measurements. 50 ohm coax measurements 10 MHz to 50 GHz. 75 ohm coax measurements 10 MHz to 2.4 GHz. Waveguide measurements 26.5 to 110 GHz. Open/short averaging, normalization, averaging, limit testing, storage registers. HP-IB programmable.
 
 