| |
 |
Model #s |
 |
Product Highlights |
 |
Key Applications |
 |
|
Agilent ENA RF Network Analyzers
- 9 or 100 kHz to 3 or 8.5 GHz, 2 or 4 ports |
|
 |
E5071B
E5071C |
 |
| |
Wide dynamic range: >123 dB at test port (typical) |
| |
Low trace noise: <0.004 dBrms at 70 kHz IFBW |
| |
Fast measurement speed: 39 ms at full 2-port cal, 1601 points |
| |
2 and 4-ports with balanced measurement |
| |
Built-in Visual Basic® for Applications (VBA) |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Advanced RF components characterization |
| |
Phase & absolute group delay measurements |
| |
Multiport measurement applications |
|
|
Agilent ENA-L RF Network Analyzer
- 300 kHz to 1.5 or 3 GHz |
|
 |
E5061A-150
E5061A-175
E5061A-250
E5061A-275
E5062A-150
E5062A-175
E5062A-250
E5062A-275
|
 |
| |
10.4 inch color LCD |
| |
Integrated T/R or S-parameter test set |
| |
50 or 75 ohm test port impedance |
| |
115 dB dynamic range and 0.005 dB rms trace noise |
| |
Built-in Visual Basic for Applications (VBA) |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Education |
| |
Basic vector analysis |
| |
CATV component measurement |
|
|
Agilent Network/Spectrum/Impedance Analyzers
- 10 Hz to 500 MHz |
|
 |
4395A
4396A
4396B |
 |
| |
Full-vector network and spectrum measurement and analysis |
| |
±0.05 dB, ±0.3° dynamic magnitude/phase accuracy |
| |
Wide dynamic range network measurement with fast sweep speeds |
| |
Extremely fast narrowband spectrum measurement |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Characterization of frequency translating RF components |
| |
Video/audio broadcast |
| |
Narrowband measurements (i.e. VCO, CN) |
| |
Wireless communications |
|
|
Agilent Microwave Vector Network Analyzers
- 50 MHz to 40 GHz |
|
 |
8719ES
8719ET
8720ES
8720ET
8722ES
8722ET |
 |
| |
100 dB dynamic range |
| |
Excellent measurement accuracy |
| |
2 measurement channels, 4 display channels |
| |
Frequency and power sweeps |
| |
Fast sweep and data transfer speed |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Testing of linear and non-linear microwave devices |
| |
Fault testing in devices, cables, etc. |
|
|
Agilent RF Vector Network Analyzers
- 30 kHz to 3 or 6 GHz |
|
 |
8753E
8753ES
8753ET |
 |
| |
Up to 110 dB dynamic range |
| |
Excellent measurement accuracy |
| |
2 measurement channels, 4 display channels |
| |
Frequency and power sweeps |
| |
Fast sweep and data transfer speed |
|
 |
| |
Production testing |
| |
Manufacturing |
| |
R&D evaluation |
| |
Testing of linear and non-linear behavior of active and passive devices |
| |
Characterization of frequency translating RF components |
| |
Fault testing in devices, cables, etc. |
| |
Variable power to test amplifiers |
| |
CATV component measurement |
| |
Harmonic measurements |
|
|
Advantest Vector Network Analyzers
- 300 kHz to 3.8 or 8 GHz |
|
 |
R3765CG
R3767CG |
 |
| |
High throughput |
| |
Wide dynamic range: 100 dB |
| |
Program sweep function |
| |
-90 dB (40 MHz to 3.8 GHz) RBW 3 kHzs input noise level |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Testing of linear and non-linear behavior of active and passive devices |
| |
Multiport applications (i.e, balanced device, dual filters) |
| |
Fault testing in devices, cables, etc. |
|
|
Advantest Component/Network Analyzers
- 300 kHz to 8 or 20 GHz |
|
 |
R3768
R3770
R3860A |
 |
| |
Sweep rate of 5µs/point |
| |
Model options available for 2 to 4 ports |
| |
System dynamic range of 125 dB (typical) |
|
 |
| |
Production testing |
| |
R&D evaluation |
| |
Testing of linear and non-linear behavior of active and passive devices |
| |
CDMA IF filter analysis |
| |
Harmonic measurements |
|
 |
| |
 |
Model #s |
 |
Product Highlights |
 |
| Agilent
Mechanical Calibration Kits |
|
 |
85032F: 30 kHz - 9GHz Type N
85033E: DC to 9 GHz 3.5mm
85052C: DC to 26.5 GHz 3.5mm
85052D: 45 MHz - 26.5 GHz 3.5mm
85054D: 45 MHz - 18 GHz 3.5mm |
 |
| |
Mechanical calibration kit contains individual standards to characterize systematic errors. Many of the kits include adapters for test ports and a torque wrench for proper connection. |
|
| Agilent
Electronic Calibration Modules |
|
 |
85092C: 300 kHz-9 GHz 2 port
85093B: 2 port 3.5mm
85093C: 2-port 3.5mm
N4431A: 300 kHz-9 GHz 4 port
N4431B: 300 kHz-13.5 GHz 4 port |
 |
| |
Electronic calibration (ECal) modules consist of connector-specific calibration standards that measure the known
devices of the system over the frequency range of interest to detect systematic errors. With simple one-connection
operation, they offer excellent accuracy without sacrificing time to calibrate. |
|
| Agilent
Test Port Cables and Adapters |
|
 |
N6314A: 24-inch Type N Cable
N6315A: 16-inch Type N Cable
11500E: 24-inch 3.5mm (m-m) Cable
11500F: 60-inch 3.5mm (m-m) Cable
1250-1744: 3.5 mm (f) to Type-N (m), DC to 18 GHz Adapter |
 |
| |
Test port cables and adapters provide the connection required when using network analyzers with various test devices and equipment. |
|
 |