| Image |
 |
Models |
 |
Product Highlights |
| Agilent
DSO80000B Series Infiniium Oscilloscopes
- 2 GHz - 6 GHz BW, 40 GSa/s, 4 Analog Chs |
|
 |
DSO80604B
|
 |
| |
Industry's only bandwidth upgradeable series - upgrade to 12 GHz for PCI-Express 2.0 |
| |
Trigger jitter less than 500 fs rms |
| |
Use with E2688A Serial Data Analysis Software and N5393A Electrical Performance Validation Software |
|
| Agilent
N5393A
- PCI-Express Electrical Performance Validation Software |
|
 |
N5393A
|
 |
| |
Test setup wizard guides you through test selection, configuration, connection, execution and results reporting |
| |
PCI-SIG SigTest clock recovery algorithm is used to ensure consistency with SigTest |
| |
Performs a wide range of electrical tests as per the PCI Express 1.0a and 1.1, as well as selected tests for PCI Express 2.0 |
|
| Agilent
E2688A
- High-Speed Serial Data Analysis and Clock Recovery Software |
|
 |
E2688A |
 |
| |
Also available as Option 003 with DSO80000 Series Oscilloscopes |
| |
Easily perform mask testing and characterize serial data streams that employ embedded clocks |
| |
8b/10b decode with symbol trigger and search |
| |
Golden PLL clock recovery |
| |
Test for illegal characters in your compliance pattern |
|
 |
| Add-in Card Testing Recommended Accessories |
Back to Top |
| Image |
 |
Models |
 |
Product Highlights |
|
PCI-SIG CBB
- Compliance Base Board |
|
 |
PCI-SIG CBB |
 |
| |
Supports testing adapter card up to 16 lanes |
| |
100-MHz reference clock oscillator is contained on the CBB |
| |
Standard ATX power supply is used to power the CBB and adapter card |
| |
Available from PCI-SIG |
|
|
Agilent 15442A
- SMA Cables |
|
 |
15442A
1810-0118 |
 |
| |
2 SMA Cables required |
| |
1810-0118: 50 ohm terminators, 6 required |
|
| System Motherboard Testing Recommended Accessories |
Back to Top |
| Image |
 |
Models |
 |
Product Highlights |
|
PCI-SIG CLB
- Compliance Load Board |
|
 |
PCI-SIG CLB |
 |
| |
Used for testing systems (motherboards) |
| |
Edge connectors on four sides to support testing of 1-, 4-, 8-, and 16-lane system connectors |
| |
Connect to the oscilloscope using either SMA cables or differential active voltage probes |
| |
Available from PCI-SIG |
|
|
Agilent 15442A
- SMA Cables |
|
 |
15442A
1810-0118 |
 |
| |
2 SMA Cables required |
| |
1810-0118: 50 ohm terminators, 6 required |
|
|
Agilent InfiniiMax Probes
- with socketed (E2678A) probe adapter |
|
 |
1134A
1169A
E2678A |
 |
| |
1134A: 7 GHz probe |
| |
1169A: 12 GHz probe |
|
|
Agilent 1250-1741
- SMA adapters |
|
 |
1250-1741
|
 |
| |
Right angle SMA adapters (f - m) |
| |
2 required |
|
 |
| Semiconductor Testing Recommended Accessories |
Back to Top |
| Image |
 |
Models |
 |
Product Highlights |
|
Agilent 86100C
- Infiniium DCA Oscilloscope Mainframe |
|
 |
86100C |
 |
| |
50 MHz to 80 GHz |
| |
Advanced waveform, TDR and jitter analysis |
| |
Extremely high accuracy and precise repeatability |
|
|
Agilent 81134A Pulse Pattern Generator
- 15 MHz to 3.35 GHz, 2 channel |
|
 |
81134A |
 |
| |
Low jitter |
| |
Fast rise times (20%-80%) < 60 ps |
| |
Variable cross-over point (eye deformation) |
|
|
|
|