| Image |
 |
Recommended
Model Numbers |
 |
Key Options |
 |
Details |
| Agilent
PSA Series Spectrum Analyzer |
|
 |
E4443A
E4445A
E4445A
E4440A
E4440A
E4447A
E4446A
E4448A |
 |
|
 |
| |
Measures and monitors complex RF, microwave and millimeter-wave signals from 6.7 GHz to 50 GHz |
| |
Optional 40 or 80 MHz analysis bandwidth to capture and measure complex signals |
| |
Wide dynamic range (-154 dBm DANL, +17 dBm TOI, -116 dBc/Hz phase noise at 10 kHz offset) |
| |
±0.62 dB absolute amplitude accuracy, ±0.38 dB frequency response, ±0.07 dB log amplification linearity |
| |
Easy-to-use built-in measurement personalities |
|
| Agilent
MXA Signal Analyzer |
|
 |
N9020A
(6.7 GHz) and above |
 |
Opt. 503: 3.6 GHz
Opt. 508: 8.4 GHz
Opt. 513: 13.6 GHz
Opt. 526: 26.5 GHz |
 |
| |
Up to 26.5 GHz frequency range |
| |
30 to 300% faster than all other spectrum and signal analyzers |
| |
25 MHz analysis bandwidth |
| |
-151 dBm/Hz DANL (-154 dBm/Hz typical) |
|
| Agilent
ESA-E Series Portable Spectrum Analyzers |
|
 |
E4402B
E4404B
E4405B
E4407B |
 |
|
 |
| |
Provides scalable mid-performance spectrum analysis from 3 to 26 GHz |
| |
10 MHz analysis bandwidth |
| |
Various one-button RF power measurements |
|
| Agilent
VSA Modulation Analysis Software |
 |
 |
89601A |
 |
Option AYA Option 200 Option 300 |
 |
| |
Wide range of troubleshooting tools for analyzing digital satellite video and other satellite signals |
| |
Flexible demodulation to analyze new wideband emerging format signals |
| |
Use with Infiniium scopes to analyzer ultra wide bandwidth signals |
|
| Agilent
High Performance and Infiniium Oscilloscopes |
|
 |
DSO80000B
8000
6000 |
 |
|
 |
| |
Recommend bandwidth of 600 MHz and above |
| |
Recommend 1M memory depth or greater |
| |
Combine with 89601A Vector Signal Analyzer software analyze super wide bandwidth signals |
|
| R&S
FSQ Signal Analyzer |
|
 |
FSQ3
and above |
 |
|
 |
The FSQ combines two instruments in one. It offers
signal analysis at a demodulation bandwidth of up to 120
MHz with the dynamic range of a high-end spectrum analyzer.
Some measurements functions include:
| |
BPSK, QPSK, 16QAM, CCK signals |
| |
EVM |
| |
Freq Error |
| |
Crest factor |
| |
Spectrum emissions masks |
| |
FFT |
| |
Payload information |
|
| R&S
FSP Spectrum Analyzer |
 |
 |
FSP3 |
 |
|
 |
General purpose spectrum analyzer, with frequency range configurable from 3GHz to 40GHz. Combine with option K8 for Bluetooth 1.1 and 2.0 transmitter measurements |
| R&S
FSL Spectrum Analyzer |
 |
 |
FSL3
FSL6 |
 |
|
 |
Allows convenience in field maintenance installation and troubleshooting
| |
9 kHz to 3/6 GHz, with or without tracking generator |
| |
IQ demodulation bandwidth 20 MHz |
| |
DANL -152 dBm |
|
 |
| Image |
 |
Recommended
Model Numbers |
 |
Key Options |
 |
Details |
| Agilent
ESG Vector Signal Generator |
|
 |
E4438C |
 |
Opt. 409: GPS
Opt. 501: 1 GHz
Opt. 502: 2 GHz
Opt. 503: 3 GHz
Opt. 504: 4 GHz
Opt. 506: 6 GHz |
 |
Arbitrary
waveform generator and I/Q modulation capability enable
the creation of complex waveforms for a variety of RF
and microwave applications, including BPSK and O-QPSK.
Can also be used as a multi-purpose interference source.
Some features include:
| |
Frequency coverage up to 6 GHz |
| |
Optional internal baseband generator with 8 or
64 megasample memory |
| |
Arbitrary waveform generation with sophisticated
real-time I/Q symbol generation |
| |
Combine with N5115B Baseband Studio For Fading |
|
| Agilent
PSG Vector Signal Generator |
|
 |
E8267D |
 |
Opt. 520: 20 GHz
Opt. 532: 31.8 GHz
Opt. 544: 44 GHz |
 |
| |
Integrated microwave vector signal generator with I/Q modulation up to 44 GHz |
| |
Advanced wideband internal baseband generator capable of flexible arbitrary waveform playback or sophisticated real-time signal generation |
|
| R&S
SMU200A Vector Signal Generator |
|
 |
SMU200A |
 |
Option K44
Option K244
Option B14 |
 |
| |
Frequency range 100 kHz to 6 GHz |
| |
Internal I/Q modulation bandwidth 80 MHz (in RF) |
| |
Arbitrary waveform generator with 64 Msamples |
| |
Up to two signal generators in one box (e.g. useful signal + interferer) |
| |
Option K44/K244 - Digital Standard GPS (WinIQSIM2: K244) |
| |
Option B14 - Fading simulator (use with PC) |
|
| R&S
SMJ100A Vector Signal Generator |
 |
 |
SMJ100A |
 |
Option K44
Option K244 |
 |
| |
Frequency range 100 kHz to 6 GHz |
| |
Internal I/Q modulation bandwidth 80 MHz (in RF) |
| |
Option K44/K244 - Digital Standard GPS (WinIQSIM2: K244) |
|
| R&S
SMV03 Vector Signal Generator |
 |
 |
SMV03 |
 |
|
 |
Vector modulation in the analog class
| |
Frequency range 9 kHz to 3.3 GHz |
| |
I/Q modulator with 100 MHz RF bandwidth and excellent vector accuracy |
| |
High level accuracy <0.5 dB |
|
| Image |
 |
Recommended
Model Numbers |
 |
Key Options |
 |
Details |
| Agilent
ENA RF Network Analyzer |
|
 |
E5071B
E5071C |
 |
|
 |
Offers the highest RF performance and fastest speed in its class, with a wide
frequency range and versatile functions. The Agilent E5071C is the ideal solution for manufacturing and
R&D engineers evaluating RF components and circuits from 9 kHz to 8.5 GHz |
| Agilent
PNA Microwave Network Analyzers |
 |
 |
E8362B
E8363B
E8364B |
 |
Option H08 |
 |
Microwave network analyzers with optional pulsed-RF capability and combined
with an external RF modulator and pulse generators, forms a powerful, pulsed S-parameter measurement solution
ideal for characterizing components used for microwave and radar applications.
| |
Up to 67 GHz frequency range |
| |
Option H08: Pulsed-RF measurement application adds average pulse, point-in-pulse and pulse profile measurement capabilities |
|
 |
| Image |
 |
Recommended
Model Numbers |
 |
Key Options |
 |
Details |
| Agilent
P Series Power Meters |
|
 |
N1911A
(1 Ch)
N1912A
(2 Ch) |
 |
|
 |
When used with the N192XA wideband power sensors, the P-Series power meters
provides a measurement frequency range from 50 MHz to 40 GHz with an internal zero and
calibration capability |
| Agilent
EPM-P Power Series Power Meters |
|
 |
E4416A
(1 Ch)
E4417A
(2 Ch) |
 |
|
 |
The EPM-P Series power meter measure peak, average and time-gated power over -65 dBm to +20 dBm, to 18 GHz using E932XA power sensors |
| Agilent
EPM Series Power Meters |
|
 |
E4418B
(1 Ch)
E4419B
(2 Ch) |
 |
|
 |
The EPM and EPM-P
Series provides high-performance, programmable power meters
for CW, average and peak power measurements. |
| R&S
NRP Power Meter |
|
 |
NRP |
 |
Power Sensors
Z11: 8 GHz, 200mW
Z21: 18 GHz, 200mW
Z22: 18 GHz, 2W
Z23: 18 GHz, 15W
Z24: 18 GHz, 30W
Z51: 18 GHz, 100mW
Z55: 40 GHz, 100mW |
 |
| |
Innovative multipath sensor technology |
| |
90 dB dynamic range |
| |
High measurement speed |
| |
Intelligent sensors – simply plug in and
measure |
| |
Accurate measurement of average power regardless
of bandwidth and modulation |
| |
Handling of external components through S-parameter correction |
| |
Simultaneous operation of up to 4 sensors on basic
unit |
|
 |
|